1. Product Overview
The ELECTESLA ES-UL300 is an intelligent ultrasonic level meter designed for precise and reliable measurement of liquid levels in various applications, including water, fuel, and oil tanks. It features intelligent acoustic technology for echo analysis and interference resistance, ensuring accurate readings.



The meter is suitable for petroleum, chemical industry, coal chemical industry, metallurgy, electric power, ship, medicine, food, textile, brewery, aerospace, military industry, and fire-fighting applications.
2. Specifications
| Attribute | Value |
|---|---|
| Model Number | ES-UL300 |
| Product Name | Ultrasonic Level Sensor |
| Measuring Range | 0-20m (Optional), 0-25m (customized) |
| Blind Area | 0.25~0.5m |
| Accuracy | 0.2%, 0.5% |
| Resolution | 1mm |
| Pressure | Below 4 atmospheres |
| Output Signal | 4~20mA, 0-10V, RS485, Relay |
| Power Supply | DC24V; AC/DC220V (Optional, with built-in lightning protection) |
| Medium | Water, Fuel, Oil etc |
| Working Temperature | -40~70℃ (high temperature customized) |
| Display | LCD display (shows level height and spatial distance) |
| Protection Grade | IP68 |
| Protection | Corrosion proof |
| Certification | CE, FCC, RoHS |
| Battery Included | No |
| High-concerned chemical | None |
Product Dimensions

3. Setup and Installation
Proper installation is crucial for accurate measurement. The ES-UL300 can be installed using a bracket mounting method in open environments.
Installation Methods
When installing in a pool or tank, cut a hole slightly larger than the probe's diameter (60mm). Place the instrument and secure it with the flange or nut from bottom to top. Ensure the probe surface is level with the measured liquid surface.

- The measured reference plane is the lower edge of the sensor.
- The upper limit of the level cannot enter the measurement blind zone.
- The feed inlet must be avoided when measuring the material level.
- It is best to protect against rain and sun when installing outdoors.
Wiring Diagram
The ES-UL300 supports both 2-wire and 4-wire configurations. Ensure correct polarity and power supply.

2-Wire Wiring: Connect to an ammeter or digital display meter and PLC. Do not use the same DC24V power supply as an inverter.
4-Wire Wiring: P is power (DC24V or AC220V optional). L1 L2 are low limits, H1 H2 are high limits. I- I+ are output 4-20mA. B A are for RS485.
4. Operation and Calibration
Key Description
- [SET]: Menu key. Press to enter the password interface, then enter the password to access the menu. After setting, press again to exit.
- [▲]: Flip-up key and numeric key. Used for navigating menus and changing data.
- [▼]: Shift key. Used as a shift key when changing data.
- [OK]: Confirmation. Selects a menu or confirms options and data.
Password Access
Press [SET] key. The password interface will display "0000". Press [▲] to change the first digit to '2' (i.e., "2000"). Press [OK] to enter the parameter setting menu.
Parameter Setting
- Liquid Level Calibration (P01): After installation and power-on, if the displayed liquid level does not match the actual level, calibration is required. This function is now realized via the P04 menu.
Automatic Calibration Steps: Press [SET], enter password, then [OK] to enter the parameter setting menu. Navigate to the P04 menu. Press [OK] for P04 probe mounting height calibration. Use [▼] and [▲] to change the value to the actual height (e.g., 2.100). Press [OK] to confirm. Press [SET] to exit. The first line will display "H" for the current liquid level, indicating successful calibration of liquid level (H) and measure distance (L).
- Full Scale 20mA Value Setting (P02): While the instrument is working normally, press [SET] to enter the parameter setting menu. Select P02. The second line shows the 20mA corresponding to the liquid level. Press [OK] to set.
- Display Mode Setting (P03): This menu allows changing the display mode:
- 00: Shows level value (H) and temperature value (F).
- 01: Shows measure distance value (L) and temperature value (F).
- 02: Shows level value (H) and measure distance value (L).
Press [▲] to select the desired mode and then [OK] to confirm.
- Probe Mounting Height Setting and Automatic Level Calibration (P04): This menu is for setting the true and valid probe mounting height. Once set, the H and L values are automatically calibrated.
- Reaction Speed Setting (P05): This menu adjusts the meter's response speed. There are 4 modes:
- 00: Fastest response speed
- 01: Faster response speed
- 02: Medium response speed
- 03: Slow response speed
Press [▲] to select the desired mode and then [OK] to confirm. Note: Faster reaction speeds may lead to bigger data display jumps. If the liquid level does not change rapidly, factory settings are usually sufficient.
- Blind Area Setting (P06): This setting allows adjustment for complex field conditions, such as avoiding nearby protruding objects. Generally, no modification is needed from factory settings.
- ID Number Setting (P07): (For 4-wire instruments only) Used for communication in multi-computer systems. Default is 01.
- Relay Output Setting (P08): (For 4-wire instruments only) The meter has two relays: H (upper limit) and L (lower limit).
To access: Press [SET], enter "0000", then change the first digit to '3' (i.e., "3000"), then [OK].
Each relay has control and return values. H relay is controlled by H (control value) and dH (return value). L relay is controlled by L (control value) and dL (return value).
High Point Relay (H): Closes when measured value > H. Breaks when measured value < (H - dH).
Low Point Relay (L): Closes when measured value < L. Breaks when measured value > (L + dL).
- Relay (Alarm Type) Setting (P09):
To access: Press [SET], enter "0000", then change the first digit to '4' (i.e., "4000"), then [OK].
Set the alarm type (e.g., PH:01 for high alarm, PL:02 for low alarm) according to your requirements.
Display Modes
The LCD display can show different information based on the selected display mode (P03):
- 00: Shows the level value (H) and temperature value (F).
- 01: Shows the measure distance value (L) and temperature value (F).
- 02: Shows the level value (H) and measure distance value (L).
5. Maintenance
The ES-UL300 is designed for durability and corrosion resistance (IP68, corrosion proof). Regular maintenance helps ensure its longevity and accurate performance.
- Cleaning: Periodically clean the ultrasonic transducer to prevent buildup that could affect readings. Use a soft cloth and avoid abrasive cleaners.
- Inspection: Regularly inspect the wiring connections for any signs of wear, corrosion, or damage. Ensure all connections are secure.
- Environmental Protection: If installed outdoors, ensure the unit is protected from extreme weather conditions, direct sunlight, and heavy rain to prevent degradation of materials and electronics.
- Firmware Updates: Check with ELECTESLA for any available firmware updates that might improve performance or add features.
For specific maintenance procedures not covered here, please refer to the official user manual PDF or contact customer support.
6. Troubleshooting
This section provides general guidance for common issues. For complex problems, refer to the detailed manual or contact technical support.
- Inaccurate Readings:
- Check for obstructions or buildup on the ultrasonic transducer. Clean if necessary.
- Verify that the installation height and blind zone settings (P04, P06) are correctly calibrated.
- Ensure the sensor is installed level and not angled.
- Avoid installing near feed inlets or sources of strong interference.
- No Display/Power Issue:
- Check the power supply (DC24V or AC/DC220V) and ensure it is correctly connected and providing the specified voltage.
- Inspect wiring for loose connections or damage.
- Output Signal Problems (4-20mA, RS485):
- Verify wiring connections for the output signal.
- Check the 20mA full scale setting (P02) if using 4-20mA output.
- For RS485, ensure the ID number (P07) is correctly set and communication parameters match the receiving device.
- Relay Malfunction:
- Review the relay output settings (P08) and alarm type settings (P09) to ensure they are configured as desired.
- Check the physical connections of the relays.
7. User Tips
- Application for Plastic Resins: The ES-UL300 can potentially be used for level measurement of plastic resins stored in aluminum tanks, provided the resin's properties (e.g., dust, viscosity, surface characteristics) do not significantly interfere with ultrasonic wave propagation. It is recommended to test in a small-scale environment first to confirm compatibility and accuracy.
- Outdoor Installation: Always protect the sensor from direct sunlight and heavy rain to ensure optimal performance and extend its lifespan.
- Interference: Be mindful of potential interference sources within the tank, such as agitators or pipes, and adjust the blind area setting (P06) if necessary to avoid false readings.
8. Warranty and Support
For detailed warranty information, please refer to the official product documentation. ELECTESLA provides technical support for its products.
A comprehensive user manual in PDF format is available for download. This document contains additional detailed instructions and specifications:
Official User Manual (PDF): View User Manual PDF
For further assistance, you may contact:
- WhatsApp: +8615665610693
- Email: sales02@jinqu-electric.com