GEYA GRV8-SV

GEYA GRV8-SV Single Phase LCD Digital Display Voltage Relay

User Instruction Manual

1. Introduction

The GEYA GRV8-SV is a single-phase LCD digital display voltage relay designed for monitoring and protecting electrical systems against overvoltage and undervoltage conditions. This device provides reliable control for various applications, ensuring the safe operation of connected equipment.

1.1 Applications

  • Control for connection of moving equipment (site equipment, agricultural equipment, refrigerated trucks).
  • Normal/emergency power supply switching.

2. Safety Information

Please read this manual carefully before installation and operation. Failure to follow these instructions may result in equipment damage or personal injury. Installation and maintenance should only be performed by qualified personnel.

  • Ensure the power supply is disconnected before any installation or wiring work.
  • Verify that the voltage and current ratings of the relay match your application requirements.
  • Protect the device from moisture, dust, and extreme temperatures.
  • Do not open or attempt to repair the device; refer to qualified service personnel.

3. Product Overview

3.1 Features

  • Controls its own supply voltage (True RMS measurement).
  • Integrated LCD display for real-time voltage monitoring and settings.
  • Measuring frequency range: 45Hz-65Hz.
  • High voltage measurement accuracy: <1%.
  • Compact 2-MODULE design for DIN rail mounting.
  • Overvoltage and undervoltage protection with adjustable delay times.
  • Two SPDT (Single Pole Double Throw) output contacts.

3.2 Components and Display

The GRV8-SV features a clear LCD and intuitive control buttons on its front panel, along with standard terminal connections.

Front view of GEYA GRV8-SV relay with LCD showing 220V

Figure 1: Front View of GRV8-SV Voltage Relay

Angled view of GRV8-SV relay with transparent cover open, showing buttons and LCD

Figure 2: Angled View with Transparent Cover Open

Front Panel Controls:

  • LCD Display: Shows current voltage, status (e.g., NORMAL), and parameter settings.
  • R/T Button: Reset/Test button.
  • MD Button: Mode button for navigating settings.
  • Up (▲) Button: Increases parameter values.
  • Down (▼) Button: Decreases parameter values.
  • R LED: Indicates relay status.

Terminal Connections:

  • A1(+), A2(-): Power supply input terminals.
  • 11, 12, 14: First SPDT output contact.
  • 21, 22, 24: Second SPDT output contact.

4. Setup

4.1 Mounting

The GRV8-SV is designed for DIN rail mounting (EN/IEC 60715). Ensure it is securely clipped onto the DIN rail in a suitable enclosure, protected from environmental factors.

Side view of GRV8-SV relay showing DIN rail mounting clips

Figure 3: DIN Rail Mounting Mechanism

4.2 Wiring Diagram

Connect the GRV8-SV according to the following diagram. Ensure all connections are tight (tightening torque: 0.4Nm) and use appropriate cable sizes (solid wire max. 1x2.5mm² or 2x1.5mm²; with sleeve max. 1x2.5mm² (AWG 12)).

Detailed wiring diagram for GEYA GRV8-SV voltage relay, showing A1, A2, L, N, KM, and output contacts 11, 12, 14, 21, 22, 24

Figure 4: GRV8-SV Wiring Diagram and Technical Parameters

Wiring Instructions:

  1. Connect the AC/DC 110V~240V power supply to terminals A1(+) and A2(-).
  2. Connect the monitored line (L and N) to the appropriate terminals as shown in the diagram for voltage sensing.
  3. Connect the load (KM - Contactor Coil) to the output contacts. For example, use 11 and 14 for Normally Open (NO) control, or 11 and 12 for Normally Closed (NC) control. Similarly for the second contact (21, 22, 24).

5. Operation

5.1 Initial Power-Up

Once wired, apply power to the A1-A2 terminals. The LCD will illuminate and display the current voltage. The relay will undergo a power-up delay before entering normal operation.

5.2 Parameter Setting

To adjust the protection parameters, use the MD, Up (▲), and Down (▼) buttons. Refer to the table below for parameter ranges and factory settings.

Table 1: Parameter Settings
Parameter Range Step Value Factory Settings
Over voltage value 65V-300V, OFF 1V 253V
Over voltage recovery value 60V-295V 1V 248V
Under voltage value OFF, 65V-300V 1V 187V
Under voltage recovery value 70V-305V 1V 192V
Voltage fault action time 0.1s-20s 0.1s 2s
Power on delay time 0.5s-300s 0.1s 0.5s
Reset time 0.5s-300s 0.1s 1s
Fault reset ON-OFF ON

5.3 Operation Description

The relay continuously monitors the input voltage. If the voltage deviates from the set overvoltage or undervoltage thresholds for the configured action delay time, the output relays will trip to protect the connected equipment.

Testing Relay Action: A short press (0.5s) of the R/T button can test the relay action. This function is only available when the power supply is normal.

Functions Diagram illustrating overvoltage tripping delay (To), undervoltage tripping delay (Tu), reset delay (Tr), and power-up delay (Tp) with corresponding LCD and LED states and output contact changes

Figure 5: Functions Diagram (Timing for Over/Undervoltage Protection)

The diagram illustrates the timing sequences for various events:

  • To: Overvoltage tripping delay.
  • Tu: Undervoltage tripping delay.
  • Tr: Reset delay.
  • Tp: Power up delay.

6. Maintenance

The GRV8-SV voltage relay is designed for long-term, maintenance-free operation. However, periodic checks are recommended:

  • Ensure all wiring connections remain secure and free from corrosion.
  • Keep the device clean and free from dust and debris.
  • Periodically verify the functionality of the relay using the test button.

7. Troubleshooting

If the device is not functioning as expected, consider the following:

  • No display/No power: Check the power supply to A1-A2 terminals. Ensure connections are correct and secure.
  • Relay not tripping: Verify the set overvoltage/undervoltage thresholds and delay times. Ensure they are appropriate for the monitored voltage. Check the wiring to the load.
  • Relay tripping unexpectedly: Check for unstable power supply or transient voltage fluctuations. Adjust delay times if necessary to avoid nuisance tripping.
  • Incorrect voltage reading: Ensure the input voltage is within the specified operating range.

8. Specifications

Dimensions diagram for the GEYA GRV8-SV relay, showing height 90mm, max width 36mm, and depth 70mm

Figure 6: GRV8-SV Dimensions (mm)

Table 2: Technical Parameters
Parameter Value
Function Over voltage, under voltage
Rated supply voltage (Un) AC/DC110V~240V
Rated supply frequency 50/60Hz (45~65Hz)
Operation voltage range 50V~350V
Burden AC max. 3VA
Over operation value 65V-300V, OFF
Under operation value OFF, 65V-300V
Over/under voltage action delay 0.1s~20s
Power-up delay 0.5s~300s
Reset time 0.5s~300s
Measurement error <1%
Output 2xSPDT
Current rating 8A/AC1
Switching voltage 250VAC/24VDC
Electrical life (AC1) 1x105
Mechanical life 1x106
Operating temperature -20°C ~ +60°C
Storage temperature -35°C ~ +75°C
Mounting DIN rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Overvoltage category III
Pollution degree 2
Max. cable size Solid wire max.1x2.5 or 2x1.5 / with sleeve max.1x2.5 (AWG 12)
Tightening torque 0.4Nm
Dimensions (H x W x D) 90mm x 36mm x 70mm
Weight 100g
Standards EN 60255-1, IEC60947-5-1
Certification CE, RoHS, CCC

9. User Tips

  • For critical applications, consider using a backup protection device or regularly testing the relay's functionality.
  • When setting delay times, balance between immediate protection and avoiding false trips due to minor fluctuations.
  • Always ensure proper ventilation around the device to prevent overheating, especially in enclosed panels.

10. Warranty & Support

For warranty information, technical support, or service inquiries, please contact GEYA customer service or your local distributor. Keep your purchase receipt for warranty claims.

A detailed user manual in PDF format is available for download. Please refer to the official GEYA website or the product page for the document titled "User manual (PDF)" (e.g., https://manuals.plus/m/f4936ebe510342ec7a46acec4bf699f5adba28aa6778c19786a632213c9e2342).

Related Documents - GRV8-SV

Preview GEYA GRV8-S 3-Phase Display Voltage Relay Instruction Manual
Comprehensive instruction manual for the GEYA GRV8-S 3-phase display voltage relay, covering applications, features, technical specifications, wiring, parameter settings, and operational descriptions for safe and efficient use.
Preview GEYA GRV8-01.02 Monitoring Voltage Relay Instruction Manual
Instruction manual for the GEYA GRV8-01.02 monitoring voltage relay. This document provides detailed information on applications, function features, technical specifications, panel and function diagrams, wiring, and safety guidelines for protecting electrical equipment and motors from over-voltage and under-voltage.
Preview GEYA GRV8-01.02 Monitoring Voltage Relay: Instruction Manual
This instruction manual provides comprehensive details on the GEYA GRV8-01.02 monitoring voltage relay, covering its applications in protecting electrical equipment and motors from over/under-voltage, function features, technical specifications, panel and function diagrams, and wiring instructions.
Preview GEYA GRV8-UV Series Under Voltage Relay Instruction Manual
Instruction manual for GEYA GRV8-UV series under voltage relays, detailing applications, features, technical specifications, wiring diagrams, and dimensions for single and three-phase industrial and commercial systems.
Preview GEYA GRV8-SV LCD Display Voltage Relay Instruction Manual
Instruction manual for the GEYA GRV8-SV LCD display voltage relay, detailing its applications, features, technical parameters, wiring, operation, and parameter settings.
Preview GEYA GPS8 Voltage / Current Protector Instruction Manual
Instruction manual for GEYA GPS8 series voltage and current protectors, detailing applications, features, technical specifications, wiring diagrams, and parameter settings for protecting household electrical equipment.