1. Introduction
The Morayelec ME201WZ is a Tuya Zigbee ultrasonic liquid level sensor designed for wireless monitoring of liquid levels in various tanks. This sensor offers reliable distance detection, ease of installation, high durability, and versatility, making it a valuable addition to any smart home or industrial monitoring project. It integrates with the Tuya Smart or Smart Life application for remote monitoring and alarm notifications.
Video 1: Demonstration of the Liquid Level Monitor's functionality, showing real-time level changes and alarm notifications on the mobile app.
2. Product Specifications
| Feature | Specification |
|---|---|
| Model Number | ME201WZ |
| Brand Name | morayelec |
| DIY Supplies | Plumbing |
| Origin | Mainland China |
| Gateway Requirement | Tuya Zigbee 3.0 (Gateway needs to be prepared separately) |
| Input Power | 100-240V AC to 5V DC |
| Maximum Level Detection (LevelMax) | 4m |
| Operation System | Android, iOS APP, Remote Control |
| Operating Temperatures | -20-80℃ |
| Compatible APP | Tuya SmartLife |
| Battery Included | No |
| High-concerned chemical | None |
| Package Dimensions (L x W x H) | 17cm x 16cm x 5cm |
| Package Weight | 0.4kg |

Figure 1: Dimensional drawing of the ME201WZ sensor.

Figure 2: Model comparison table, highlighting that ME201WZ does not include a Zigbee gateway.
3. Setup Instructions
3.1 Physical Installation
- In the center of the tank, paste the provided 3M installation mark.
- Drill a hole with a diameter of 55mm precisely in the middle of the marked area.
- Place the sensor over the hole, ensuring it is centered and the probe remains unobstructed.
- Fasten the sensor securely using self-tapping screws.

Figure 3: Step-by-step guide for mounting the sensor on a tank.
Important Considerations for Sensor Placement:
- Hold the sensor perpendicular to the liquid surface for accurate readings.
- Install the sensor away from any water inlets to prevent pseudo-echoes that can distort measurements.
- Avoid installing the sensor too close to the tank bulkhead, as this can also cause strong pseudo-echoes.
- Ensure there are no obstacles within the reflective area of the sensor to guarantee proper operation.

Figure 4: Guidelines for optimal sensor placement within a tank.

Figure 5: Sensor beam angle and reflection area requirements for accurate measurement.
3.2 Powering On
First, connect the AC/DC adapter to a power source, then connect it to the sensor to power it on.
3.3 App Installation and Connection
- Scan the QR code provided in the product packaging or search for “TUYA Smart APP” or “Smart Life APP” in your mobile device’s app store and download it.
- Network Reset: Press and hold the button on the sensor for 5 seconds. The LED light will flash rapidly. Release the button to initiate the network reset. The device will then attempt to connect to the network automatically.
- Connecting to App: Ensure your phone's Wi-Fi and Bluetooth are turned on. Open the Tuya Smart or Smart Life app.
- If you are using a separate Zigbee gateway, you will first need to add the gateway to the app. Follow the in-app instructions for adding a new device, typically by selecting 'Add Device' and then searching for the gateway.

Figure 6: App interface for entering Wi-Fi details during gateway setup.

Figure 7: App interface showing the discovery and addition of a Mini Multi-Mode Gateway.

Figure 8: App interface confirming gateway is online and ready to add Zigbee devices.
- Once the gateway is connected (if applicable), proceed to add the ME201WZ sensor. In the app, select 'Add Device' and follow the prompts to discover and connect your sensor.

Figure 9: App interface for adding the ME201WZ Level Sensor.
4. Operating Instructions
4.1 Monitoring Liquid Level
Once connected, the sensor will continuously monitor the liquid level within the tank. The detection range is from 10 cm to 400 cm. You can view the current liquid level, ratio, and status (Normal, Full Alarm, Lower Alarm) directly from the Tuya Smart or Smart Life app.

Figure 10: App display for different liquid level statuses and alarms.
4.2 App Settings
Within the app, you can customize various settings for the sensor:
- Set Installation Height: This is the distance from the sensor to the bottom of the tank. Accurate setting is crucial for correct depth readings.
- Pump Working Mode: The default pump working mode is 'Refilling'. This can be adjusted based on your needs.
- Set Max for High Level Alarm: Define the maximum liquid level threshold. An alarm and message notification will be triggered if the liquid level exceeds this value.
- Set Min for Low Level Alarm: Define the minimum liquid level threshold. An alarm and message notification will be triggered if the liquid level falls below this value.
4.3 Optional Pump Control
The sensor can be integrated with a pump system (via a solid-state relay, not included) to automate liquid level management. When configured, the sensor can trigger the pump based on the set high and low alarm thresholds, for example, to refill a tank when the level is low.

Figure 11: Example setup for automatic pump control based on liquid level.
4.4 Multi-Tank Monitoring
The Tuya Smart/Smart Life app allows for monitoring multiple ME201WZ sensors simultaneously, providing a comprehensive overview of liquid levels across various tanks from a single interface.

Figure 12: App interface demonstrating multi-tank monitoring capability.
5. Maintenance
- Regular Cleaning: Periodically inspect the sensor's surface for any dirt, debris, or buildup that might obstruct the ultrasonic waves. Clean gently with a soft, damp cloth.
- Connection Check: Ensure all power and network connections remain secure and free from corrosion.
- Software Updates: Keep the Tuya Smart or Smart Life app updated to the latest version to ensure optimal performance and access to new features.
- Environmental Conditions: While the sensor is designed for a wide operating temperature range (-20-80℃), extreme conditions can affect its lifespan. Protect it from direct harsh weather if possible.
6. Troubleshooting
- No Reading/Incorrect Reading:
- Check power supply to the sensor.
- Verify sensor placement according to installation guidelines (perpendicular, away from inlets, not too close to bulkhead).
- Ensure no obstacles are in the sensor's reflective area.
- Confirm the 'Installation Height' setting in the app is accurate.
- Sensor Offline in App:
- Check the power supply to the sensor and the Zigbee gateway.
- Ensure the Zigbee gateway is connected to your Wi-Fi network and is online.
- Perform a network reset on the sensor (press and hold button for 5s until LED flashes rapidly).
- Ensure your phone's Wi-Fi and Bluetooth are enabled during the connection process.
- Alarms Not Triggering:
- Verify that the 'Max for High Level Alarm' and 'Min for Low Level Alarm' thresholds are correctly set in the app.
- Check app notification settings on your phone to ensure alerts are not blocked.

Figure 13: Feature comparison highlighting advantages that minimize common issues found in older sensor designs.
7. User Tips
- Zigbee Gateway is Essential: Remember that the ME201WZ model requires a separate Tuya Zigbee 3.0 gateway to function. Ensure you have one prepared for seamless integration.
- Accurate Measurement: Users have reported accurate water level measurements and effective monitoring reminders, making it reliable for critical applications.
- Fast Connection: The sensor is noted for its fast connection speed and wide coverage, contributing to a smooth user experience.
- Compact Design: Its compact appearance makes it suitable for various installation environments without being obtrusive.
8. Warranty and Support
Morayelec is an IoT solutions company specializing in wireless monitoring of tank levels and pipeline pressure, with extensive experience in R&D, production, and sales since 2011. For technical support or warranty inquiries, please contact your retailer or visit the official Morayelec website for contact information. Keep your purchase receipt as proof of purchase for warranty claims.