1. Introduction
The ZK-10022C is a third-generation upgraded CNC DC stabilized power supply module designed for high-voltage and high-power applications. It features adjustable constant voltage and constant current output, a 1.8-inch large color screen display, and supports various communication methods for enhanced control and monitoring. This manual provides detailed instructions for its setup, operation, and advanced features.

Figure 1: ZK-10022C Power Supply Module with Color Screen Display
2. Key Features
- Third Generation Upgrade: Enhanced performance and reliability.
- Adjustable Output: Output voltage 0-125V, output current 0-22A.
- High Power: Up to 1500W output power.
- Color Screen Display: 1.8-inch large screen (36 * 29mm visualization range) for intuitive display of voltage, current, power, and protection status.
- Silicon Rubber Keypads: Effortless, silent, soft, durable, damping perception, waterproof, and dustproof buttons for improved user experience and longevity.
- Communication Support: Supports serial communication, standard MODBUS protocol, and extended serial port screen.
- APP/PC Control: Connects via Bluetooth (ZK-BT module) or USB to TTL module (ZK-U2T) for remote control and monitoring via a dedicated APP (Wuzhi Zhilian) or PC software.
- Data Storage: 11 groups of data storage for quick recall of settings (M0-M10).
- Comprehensive Protection: Includes Undervoltage Protection (LVP), Overvoltage Protection (OVP), Overcurrent Protection (OCP), Overpower Protection (OPP), Over Temperature Protection (OTP), Timeout Protection (OHP), Overcapacity Protection (OAH), and Overenergy Protection (OWH).
- PCB Sinking Gold Process: Ensures protection, conductivity, and reliability, preventing missing LCD segments, protecting pads from oxidation, improving conductivity, and reducing impedance.
3. Specifications

Figure 2: Detailed Product Parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product Name | CNC DC buck power supply (Color screen) | Product Model | ZK-10022C |
| Input Voltage | 12-140V | Output Voltage | 0.0-125.0V |
| Output Current | 0-22A | Voltage Accuracy | ±0.3%+3 words (Calibratable) |
| Output Power | 0-1500W | Current Accuracy | ±0.5%+3 words (Calibratable) |
| Voltage Resolution | 0.1V | Current Resolution | 0.01A |
| Data Group Storage | 11 groups | Silicon Rubber Keypads | 5 |
| Screen Size | Upgraded 1.8-inch large screen, 36 * 29mm visible range | Buzzer | Yes |
| Cooling Fan Conditions | Temperature > 45 °C or current > 2A or power > 30W | Product Shell | 83x48x29.4mm (Height does not include rotary encoder) |
| Product Motherboard | 130x84x42mm | Net Weight of Motherboard | 227g |
| Entire Set Net Weight | 270g | Entire Set Packaging Weight | 325g |

Figure 3: Product Dimensions and Suggested Opening Size for Enclosure
4. Package Contents
The standard package includes:
- ZK-10022C Power Supply Module (main board)
- Color Screen Display Unit (if selected)
- Connection Cables for Display Unit
- ZK-BT Bluetooth Module (if selected)
- ZK-U2T USB to TTL Module (if selected for PC communication)

Figure 4: Example of Product Packaging
5. Setup and Connection
5.1 Basic Connection
Connect the input voltage (12-140V DC) to the 'IN' terminals and your load to the 'OUT' terminals. Ensure correct polarity. The module is a voltage reduction module; the maximum output voltage is approximately (input voltage * 0.95) - 1V.
5.2 Connecting the Display Unit
The color screen display unit connects to the main board via the provided cable. The serial screen can be plugged into any port. Ensure the baud rate of the serial port screen is consistent with the power board (default 115200, adjustable) and the RX TX cable sequence is connected correctly.

Figure 5: Extended Serial Port Screen Connection Diagram
5.3 Independent Motherboard Use (ZK-10022B)
If using the ZK-10022B motherboard independently without a serial screen or APP/PC control, it is necessary to solder the voltage and current adjustment potentiometers and plug in the jumper cap. For digital communication control (serial screen, APP, PC), the jumper cap must be unplugged.

Figure 6: ZK-10022B Motherboard with Analog Potentiometer Connections
5.4 APP Connection (Bluetooth)
- Insert the ZK-BT Bluetooth module into the communication interface of the power motherboard. The ZK-BT indicator light will flash once when inserted.
- Open the 'Wuzhi Zhilian' APP on your Android or iOS device.
- Click "Add Device" on the APP interface. The APP will automatically search for "Wuzhi Power".
- After successful connection, the APP will display a confirmation.
- Click on the device icon to enter the normal operation interface. Long press the product icon to change the device name or delete it.

Figure 7: ZK-BT Bluetooth Module for APP Connectivity

Figure 8: APP Connection Steps

Figure 9: Wuzhi Zhilian APP Interface for Android and iOS
5.5 PC Connection
- Insert a data cable into your computer and connect it to the ZK-U2T (USB to TTL module). The other end of the ZK-U2T module has a 4P cable that needs to be inserted into the communication port of the power motherboard.
- Find the port number (COMx) corresponding to the USB-Serial CH340 in your computer's Device Manager under 'Ports'.
- Open the "Wuzhi Zhilian" upper computer software. Select the corresponding COM port number and click the "Connect" button in the bottom left corner of the upper computer to automatically connect.
- Note: If the software cannot run, ensure you have .NET Framework 4.8 installed. You can download and install it from the official .NET website.

Figure 10: PC Connection Steps

Figure 11: Wuzhi Zhilian PC Software Interface
6. Operation Instructions
6.1 Interface Introduction
The ZK-10022C features multiple display interfaces for comprehensive monitoring and control:
- Main Interface: Displays real-time output voltage, current, power, set voltage (V-SET), set current (I-SET), overvoltage protection (OVP), overcurrent protection (OCP), data storage group, CV/CC protection status, button sound indication, key lock status, and interface status.
- Statistics Interface: Shows output capacity (AH), output energy (WH), statistical time, and input voltage (VN).
- Curve Display Interface: Visualizes output voltage, current, and power over time with adjustable voltage and current scales.
- Menu Interface: Accesses system parameters and settings.
- Data Group Settings Interface: Allows configuration of parameters for each of the 11 data groups (M0-M10).

Figure 12: Main and Statistics Interface Overview

Figure 13: Examples of Multiple Interface Displays
6.2 Key Functions

Figure 14: Key Functions and Their Actions
- Short Press (Rotary Encoder): Select setting bit.
- Long Press (Rotary Encoder): Open/Cancel lock function.
- Left Rotation (Rotary Encoder): Number reduction during setup; switching interface display.
- Right Rotation (Rotary Encoder): Number increase during setup; switching interface display.
- M/↑ Button: Short press to call up data group settings.
- V-SET Button: Short press to enter voltage setting; Long press to enter OVP settings.
- I-SET Button: Short press to enter current setting; Long press to enter OCP settings.
- OK/↓ Button: Short press for OK/confirm.
- Power Button (on Rotary Encoder): Short press to turn on/off output; Long press for sleep shutdown.
6.3 Setting Voltage and Current
- Set Voltage: Short press the V-SET button to enter voltage setting mode. Rotate the rotary encoder to adjust the voltage value. Short press the rotary encoder to shift between digits. Press V-SET or OK/↓ again to exit the setup.
- Set Current: Short press the I-SET button to enter current setting mode. Rotate the rotary encoder to adjust the current value. Short press the rotary encoder to shift between digits. Press I-SET or OK/↓ again to exit the setup.

Figure 15: Setting Voltage and Current
6.4 Data Group Management
The module supports 11 data groups (M0-M10) to store and recall frequently used settings.
- Call Out Data Group: Press the M/↑ button to call up the data group settings. Rotate the encoder to switch between data groups M0-M10. Press OK/↓ to confirm and exit.
- Set Data Group Parameters: Short press M/↑ to select the settings option within the data group interface. Once settings are complete, short press OK/↓ to confirm and exit.

Figure 16: Data Group Setting Interface

Figure 17: Detailed Data Group Parameters
6.5 Locking Function
To prevent accidental changes to settings, the display unit has a locking function.
- On the normal display interface, long press and hold the rotary encoder for 2 seconds to lock the set voltage and current.
- To unlock, long press and hold the encoder for 2 seconds again.
- When locked, the power button can still operate normally, ensuring the power can be disconnected at any time.

Figure 18: Locking and Unlocking the Display
6.6 Video Demonstration
Video 1: Demonstration of ZK-10022C display, settings, and interface navigation.
7. Protection Mechanisms
The ZK-10022C module incorporates several protection features to ensure safe operation:
| Protection Type | Description | Adjustable Range | Factory Default |
|---|---|---|---|
| LVP (Under Voltage Protect) | Input undervoltage protection | 11-125V adjustable | 11V |
| OVP (Output Overvoltage Protection) | Output overvoltage protection | 1-130V adjustable | 130V |
| OCP (Output Overcurrent Protection) | Output overcurrent protection | 0.01-23A adjustable | 23A |
| OPP (Output Overpower Protection) | Output overpower protection | 1-1500W adjustable | 1500W |
| OTP (Over Temperature Protection) | Over temperature protection | 30-99°C adjustable | 60°C |
| OHP (Timeout Protection) | Protection for operation exceeding a set time | 1-99 hours and 59 minutes | Factory default off |
| OAH (Overcapacity Protection) | Protection for exceeding a set output capacity | 0.001-9999Ah | Factory default off |
| OWH (Superenergy Protection) | Protection for exceeding a set output energy | 0.001-4000KWh | Factory default off |

Figure 19: Protection Mechanism Details
Important Notes:
- It is not allowed to input AC power, let alone connect to 220V mains power.
- The maximum allowable input voltage is 140V. Overvoltage input or reverse polarity connection is not allowed.
- The output cannot fully guarantee anti-backflow. When connecting the battery, it is necessary to ensure that the output voltage of the power module is always higher than the battery voltage, or to connect a diode in series with a unidirectional conduction at the output positive pole to prevent battery voltage backflow from burning out the power supply.
- When connecting the output terminal to the battery, be careful not to reverse the positive and negative poles.
- The product is a voltage reduction module; the maximum output voltage is approximately (input voltage * 0.95) - 1V.
8. Calibration
The module supports voltage and current calibration for improved accuracy.
8.1 Voltage Calibration Steps:
- Use a multimeter to measure the actual voltage at the current output terminal (output terminal unloaded), measure the power terminal and input it.
- Short press OK/↓ to display voltage 2.
- Use a multimeter to measure the actual voltage at the current output terminal again and input it.
- Short press OK/↓ to complete the calibration.
- If calibration is successful, it will display "CALI Success" and exit; otherwise, it will display "CALI Failed" and exit. If it fails, you can try calibrating again.
8.2 Current Calibration Steps:
- Use a multimeter current range or electronic load to short circuit the output terminals and measure the current actual current and input it.
- Short press OK/↓ to display current 2.
- Use a multimeter to measure the actual current at the current output terminal again and input it.
- Short press OK/↓ to complete the calibration.
- If calibration is successful, it will display "CALI Success" and exit; otherwise, it will display "CALI Failed" and exit. If it fails, you can try calibrating again.

Figure 20: Calibration Steps and Other Menu Settings
9. User Tips
- Always double-check input and output polarity before powering on to prevent damage.
- When using the module with batteries, consider adding a diode to prevent reverse current flow into the power supply.
- Utilize the data group storage feature to quickly switch between common voltage/current settings for different projects.
- For precise applications, perform voltage and current calibration regularly using a high-quality multimeter.
- The locking function is useful to prevent accidental changes during long-term operation or in environments where settings might be inadvertently altered.
10. Troubleshooting
- No Output: Check input voltage, ensure output is enabled (short press power button), and verify protection settings (OVP, OCP, LVP) are not triggered.
- Inaccurate Readings: Perform voltage and current calibration as described in Section 8.
- Display Not Working: Check cable connections between the main board and the display unit. Ensure the baud rate is correctly set if using a serial screen.
- APP/PC Connection Issues: Verify the ZK-BT or ZK-U2T module is correctly installed and its indicator light is active. For PC, ensure correct COM port selection and .NET Framework 4.8 is installed.
- Overheating: Ensure adequate ventilation around the module. The cooling fan should activate if temperature exceeds 45°C, current exceeds 2A, or power exceeds 30W. Reduce load if overheating persists.
- Settings Not Saving: Ensure you confirm settings with OK/↓ after adjustment.
11. Maintenance
- Keep the module clean and free from dust. Use a soft, dry cloth for cleaning.
- Avoid exposing the module to moisture or extreme temperatures.
- Regularly check all connections for tightness and signs of wear.
- Ensure proper ventilation to prevent overheating, especially during high-power operation.
- The silicone buttons are designed for durability and are waterproof/dustproof, requiring minimal maintenance.