1. Introduction
This manual provides detailed instructions for the safe and efficient operation of your HKFZ Pure Sine Wave Solar Inverter. This wall-mounted inverter is designed for solar and off-grid applications, converting DC power from batteries into stable AC power suitable for a wide range of electrical appliances. It features a robust design and intelligent display, making it ideal for complex solar input voltage environments.
The inverter is available in two main power variants: a 10000W Peak Power model (5000W Continuous Power) and a 6600W Peak Power model (3300W Continuous Power).

Figure 1: HKFZ 10000W Pure Sine Wave Inverter with remote control
2. Specifications
| Feature | Specification |
|---|---|
| Type | DC/AC Pure Sine Wave Inverter |
| Peak Power (10KW Model) | 10000W |
| Continuous Power (10KW Model) | 5000W |
| Peak Power (6.6KW Model) | 6600W |
| Continuous Power (6.6KW Model) | 3300W |
| Input Voltage (DC) | 12V / 24V / 48V / 60V / 72V / 96V (model dependent) |
| Operating Voltage Range (12V) | 10V-15.5V |
| Operating Voltage Range (24V) | 21V-30V |
| Operating Voltage Range (48V) | 44V-58V |
| Operating Voltage Range (60V) | 53V-72V |
| Operating Voltage Range (72V) | 63V-88V |
| Operating Voltage Range (96V) | 82V-118V |
| Output Voltage (AC) | 220V~230V |
| Output Frequency | 50Hz |
| Output Waveform | Pure Sine Wave |
| No-load Current Consumption | ≤11.8W |
| Output Efficiency | 88%-95% |
| Storage Temperature | -20°C to +60°C |
| Compatible Battery Types | Iron lithium, Lead-acid, Lithium, Gel, etc. |
| Certifications | CE |
| Dimensions (10KW Model) | 43 x 22 x 11 cm |
| Weight (10KW Model) | 5 kg |
| Dimensions (6.6KW Model) | 38 x 25 x 11 cm |
| Weight (6.6KW Model) | 4.05 kg |

Figure 2: 10000W Inverter Specifications

Figure 3: 6600W Inverter Specifications
3. Safety Instructions
Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electrical shock, fire, or serious injury.
- Ensure the inverter is installed in a well-ventilated, dry environment, away from direct sunlight, heat sources, and flammable materials.
- Verify that the DC input voltage from your battery bank matches the inverter's specified input voltage (e.g., 12V, 24V, 48V). Incorrect voltage can damage the unit.
- Always connect the battery terminals with correct polarity: red to positive (+), black to negative (-). Reverse polarity will cause severe damage.
- Do not overload the inverter. Ensure the total continuous power consumption of connected appliances does not exceed the inverter's continuous power rating.
- Ensure proper grounding of the inverter.
- Keep the inverter away from children and unauthorized personnel.
- Do not open the inverter casing unless you are a qualified technician. There are no user-serviceable parts inside.
- The inverter is equipped with multiple protection features:

Figure 4: All-Round Protection Features
- Short Circuit Protection: Protects against output short circuits.
- Low Voltage Protection: Shuts down if input DC voltage drops too low.
- OverVoltage Protection: Shuts down if input DC voltage exceeds safe limits.
- Over Heating Protection: Shuts down if internal temperature becomes too high.
- Over Load Protection: Shuts down if connected load exceeds capacity.
- Low Pressure Alarm: Alerts to low input voltage.
- Over Voltage Recovery: Resumes operation after overvoltage condition clears.
- Low Pressure Recovery: Resumes operation after low voltage condition clears.
4. Product Components and Features
4.1 External Features
- Multifunction Display: Provides real-time data including input voltage (DC), output power (W), output voltage (AC), frequency (Hz), and temperature (°C). It also features input voltage and power pointers for quick visual reference.
- DC Input Terminals: Clearly marked positive (red) and negative (black) terminals for battery connection.
- AC Output Sockets: Universal sockets for connecting AC appliances.
- On/Off Switch: Main power switch for the inverter.
- Cooling Fans: Dual smart fans for efficient heat dissipation, ensuring stable operation and low noise.
- Remote Control (Optional): For convenient operation from a distance.

Figure 5: Multifunction Display Details

Figure 6: DC Input Terminals and Cooling Fans

Figure 7: AC Output Sockets and On/Off Switch
4.2 Internal Features
- Heat Sink: Large heat sinks for efficient thermal management.
- Fuses: Integrated fuses for circuit protection.
- Smart Fan Control: Fans operate intelligently based on temperature and load to optimize cooling and reduce noise.

Figure 8: Internal Components
5. Setup and Installation
5.1 Choosing an Installation Location
- Install the inverter in a cool, dry, and well-ventilated area.
- Mount the inverter securely on a wall using appropriate fasteners.
- Ensure there is sufficient clearance around the inverter for airflow, especially around the cooling fans.
5.2 Wiring Diagram for Solar Conversion
For solar power systems, follow this general wiring sequence:
- Connect solar panels to an MPPT (Maximum Power Point Tracking) charge controller.
- Connect the MPPT charge controller to your battery bank.
- Connect the battery bank to the DC input terminals of the inverter.
- Connect your AC appliances to the AC output sockets of the inverter.

Figure 9: Solar Conversion Wiring Diagram
5.3 Battery Connection
- Before connecting, ensure the inverter's main power switch is OFF.
- Connect the positive (+) terminal of the battery bank to the red positive terminal of the inverter.
- Connect the negative (-) terminal of the battery bank to the black negative terminal of the inverter.
- Ensure all connections are tight and secure to prevent arcing and overheating.
5.4 Choosing a Suitable Battery
The working time of your inverter system depends on your battery's capacity and the power consumption of your appliances. Use the following formula to estimate:
Working Time = U (voltage) x (battery capacity) x 0.8 x Conversion efficiency ÷ Power Consumption
Where:
- U = Battery voltage (e.g., 12V, 24V)
- Battery capacity = Total Ah of your battery bank
- 0.8 = A common discharge factor for batteries
- Conversion efficiency = Inverter efficiency (e.g., 0.88 to 0.95)
- Power Consumption = Total wattage of connected appliances

Figure 10: Battery Selection and Connection Examples
6. Operating Instructions
6.1 Powering On/Off
- Ensure all connections (battery, AC appliances) are secure.
- Flip the main On/Off switch on the inverter to the 'ON' position. The multifunction display will light up.
- To power off, disconnect AC appliances, then flip the main On/Off switch to the 'OFF' position.
6.2 Monitoring the Display
The intelligent multifunction display provides critical operational information:
- Input DC Voltage: Shows the current voltage from your battery bank.
- Output AC Voltage: Displays the stable 220V~230V AC output.
- Output Power: Indicates the real-time power consumption of connected appliances in Watts.
- Frequency: Shows the output frequency, typically 50Hz.
- Temperature: Displays the internal operating temperature of the inverter.
6.3 Understanding Peak Power and Continuous Power
It's crucial to differentiate between peak power and continuous power:
- Peak Power: Refers to the maximum power the inverter can withstand at the moment of startup, especially for motor-type loads which have a large instantaneous starting current.
- Continuous Power: Refers to the power the inverter can work continuously under normal conditions. The continuous power of the inverter must be greater than the power marked on the electrical appliance for long-term operation.

Figure 11: Peak Power vs. Continuous Power
6.4 Remote Control Operation (if applicable)
If your inverter model includes a remote control, refer to its specific instructions for remote power on/off and monitoring functions.

Figure 12: Inverter with Remote Control
6.5 Wide Application
Due to its pure sine wave output, this inverter can be connected to almost all electrical appliances on the market, including sensitive electronics.

Figure 13: Wide Application Examples
7. Maintenance
- Cleaning: Regularly clean the exterior of the inverter with a dry cloth. Ensure the cooling fan vents are free from dust and debris to maintain optimal airflow.
- Connections: Periodically check all electrical connections to ensure they are tight and free from corrosion.
- Environment: Maintain the inverter in a stable environment within the recommended storage temperature range of -20°C to +60°C.
- Battery Health: Regularly monitor the health and charge level of your battery bank for optimal inverter performance and longevity.

Figure 14: Efficient Cooling System
8. Troubleshooting
The inverter's intelligent display and built-in protection features help identify and mitigate common issues. If the inverter is not functioning as expected, consider the following:
- No Output Power: Check the main On/Off switch. Verify battery connections and ensure the battery voltage is within the operating range displayed on the screen. The inverter may have shut down due to low voltage protection.
- Overload Alarm/Shutdown: Reduce the total wattage of connected appliances. Ensure the continuous power draw does not exceed the inverter's rated continuous power.
- Overheating Shutdown: Ensure the inverter is in a well-ventilated area and the cooling fan vents are clear. Allow the unit to cool down before restarting.
- Low Voltage Alarm: Recharge your battery bank. The inverter will typically resume operation once the voltage recovers.
- Unusual Noises: While the fans operate, excessive or unusual noises might indicate an issue. Ensure the unit is stable and not vibrating excessively.
If the problem persists after checking these points, please contact customer support.
9. User Tips
- Match Voltage: Always ensure your battery bank voltage (e.g., 12V, 24V) precisely matches the input voltage requirement of your specific inverter model. Mismatched voltages can cause irreversible damage.
- Cable Sizing: Use appropriately sized cables for connecting the inverter to your battery bank. Undersized cables can lead to voltage drop and overheating, reducing efficiency and potentially causing safety hazards.
- Soft Start Appliances: For appliances with high startup (peak) power requirements, it's often best to turn them on one at a time rather than all at once to avoid tripping the inverter's overload protection.
10. Warranty and Support
This HKFZ Pure Sine Wave Inverter is CE certified, indicating compliance with European safety, health, and environmental protection standards.
For any warranty claims, technical support, or service inquiries, please contact your original seller or the manufacturer directly. Please have your purchase details and product model information ready when contacting support.
Video 1: HKFZ Pure Sine Wave Inverter Product Overview