VEVOR EML3500-24L / EM5500-48L

Rate this product if you’ve used it
Contents

VEVOR Hybrid Solar Inverter User Manual

Models: EML3500-24L / EM5500-48L

Efficient Solar Power Management

1. Introduction

The VEVOR Hybrid Solar Inverter is an advanced 2-in-1 system seamlessly integrating an inverter and a charge controller. It provides a robust pure sine wave output, designed for efficient solar power management in off-grid solar PV systems. Available in 3500W and 5500W models, this inverter offers outstanding peak performance and utilizes advanced MPPT charging technology to achieve up to 96% conversion efficiency. It is compatible with various battery types, including lithium-ion, lead-acid, and lithium-iron phosphate batteries, making it a versatile power solution for home, commercial, RV, and camping environments.

VEVOR Hybrid Solar Inverter front view with airflow indicators

Figure 1: VEVOR Hybrid Solar Inverter

2. Safety Information

Please read and understand all safety instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury. This device generates high voltage and current; professional installation is highly recommended.

2.1 General Safety Precautions

  • Ensure all wiring is performed by qualified personnel and complies with local electrical codes.
  • Do not attempt to disassemble or repair the inverter yourself. Contact qualified service personnel.
  • Keep the inverter away from flammable materials, moisture, and direct sunlight.
  • Ensure adequate ventilation around the inverter to prevent overheating.
  • Always disconnect power from both the solar array and batteries before performing any maintenance or wiring.

2.2 Multi-layered Protection Features

The VEVOR Hybrid Solar Inverter is equipped with comprehensive protection mechanisms to ensure stable and reliable power delivery:

Diagram showing multi-layered protection features including over current, over voltage, over-temperature, under voltage, short circuit, and over load protection.

Figure 2: Multi-layered Protection Features

  • Over Current Protection: Safeguards against excessive current flow.
  • Over Voltage Protection: Prevents damage from voltage surges.
  • Over-Temperature Protection: Shuts down the unit if internal temperatures exceed safe limits.
  • Under Voltage Protection: Protects batteries from deep discharge.
  • Short Circuit Protection: Automatically disconnects in case of a short circuit.
  • Over Load Protection: Prevents damage when connected loads exceed the inverter's capacity.

3. Product Overview

The VEVOR Hybrid Solar Inverter combines the functionalities of a solar inverter and a charge controller into a single unit, offering high efficiency and versatility.

3.1 Key Features

  • Pure Sine Wave Output: Provides clean and stable power suitable for sensitive electronics.
  • Advanced MPPT Technology: Maximizes solar energy harvesting with up to 96% conversion efficiency.
  • Versatile Battery Compatibility: Supports 24V (for 3500W model) or 48V (for 5500W model) battery systems, including Lead-Acid, Lithium, and LiFePO4 batteries.
  • Lithium Battery Activation: Automatically activates and charges lithium batteries when they run out, requiring no manual intervention. Features RS232/RS485 communication ports for BMS monitoring.
  • Multiple Charging Modes: Offers Solar Charging, Utility Charging, and Hybrid Charging options.
  • Multiple Load Output Modes: Includes UTL (Utility first), SOL (Solar first), SBU (Solar-Battery-Utility), and SUB (Solar-Utility-Battery) modes.
  • Multi-functional LCD Panel: Allows effortless monitoring of system status, parameters, and fault indications.
Comparison chart showing 96% conversion efficiency for MPPT versus 52% for PWM technology.

Figure 3: MPPT Conversion Efficiency

Diagram illustrating versatile battery compatibility with VRLA (Lead-Acid), LiFePO4 (Lithium Iron Phosphate), and NMC (Lithium Nickel Manganese Cobalt Oxide) battery types for 24V systems.

Figure 4: Versatile Battery Compatibility

Close-up of the inverter showing RS232/RS485 communication ports for lithium battery activation and status monitoring.

Figure 5: Lithium Battery Activation and Communication Ports

4. Specifications

4.1 Model EML3500-24L (3500W)

Detailed specifications and dimensions for the 3500W VEVOR Hybrid Solar Inverter (EML3500-24L).

Figure 6: EML3500-24L Specifications

ParameterValue
Item Model NumberEML3500-24L
Input Voltage220/230V AC
Output VoltageAC 230V, 50 Hz
Inverter Response Time10 ms (UPS); 20 ms (appliance)
Output WaveformPure Sine Wave
Battery Type24V, Lead-Acid, Lithium, and LiFePO Batteries
Rated Power3500W ±10%
Max. Charging Current60A(PV)/80A(AC)/120A(PV+AC)
PV Array MPPT Voltage Range30-160V DC
No-load Self-consumption≤ 20W
Product Dimensions14.4 x 12.2 x 4.2 in / 365 x 310 x 107 mm
Net Weight13.7 lbs / 6.2 kg

4.2 Model EM5500-48L (5500W)

Detailed specifications and dimensions for the 5500W VEVOR Hybrid Solar Inverter (EM5500-48L).

Figure 7: EM5500-48L Specifications

ParameterValue
Item Model NumberEM5500-48L
Input Voltage220/230V AC
Output VoltageAC 230V, 50 Hz
Inverter Response Time10 ms (UPS); 20 ms (appliance)
Output WaveformPure Sine Wave
Battery Type48V, Lead-Acid, Lithium, and LiFePO Batteries
Rated Power5500W ±10%
Max. Charging Current100A(PV)/80A(AC)/100A(PV+AC)
PV Array MPPT Voltage Range500V DC
No-load Self-consumption≤ 20W
Product Dimensions17.5 x 12.3 x 4.2 in / 445 x 313 x 107 mm
Net Weight18.4 lbs / 8.35 kg

5. Setup and Installation

Proper installation is critical for the safe and efficient operation of your hybrid solar inverter. It is strongly recommended that installation be performed by a certified electrician or solar professional.

5.1 Mounting the Inverter

  • Choose a cool, dry, and well-ventilated location, away from direct sunlight and heat sources.
  • Ensure the mounting surface is sturdy enough to support the inverter's weight.
  • Allow sufficient clearance around the inverter for proper airflow and heat dissipation.

5.2 Wiring Connections

Follow the diagram below for a typical solar AC power system setup. Ensure all connections are secure and correctly polarized.

Wiring diagram showing how to set up a solar AC power system, including solar charging, AC charging, battery connection, and AC output to appliances.

Figure 8: Solar AC Power System Setup Diagram

  1. Battery Connection: Connect the battery bank (24V for 3500W, 48V for 5500W) to the inverter's battery terminals. Ensure correct polarity (positive to positive, negative to negative).
  2. Solar Panel (PV Array) Connection: Connect your solar panels to the PV input terminals. Ensure the PV array voltage and current are within the inverter's specified MPPT range.
  3. AC Input Connection (Utility/Generator): Connect the AC utility grid or a generator to the AC input terminals. This allows for utility charging and bypass functionality.
  4. AC Output Connection (Loads): Connect your AC appliances and loads to the AC output terminals. Ensure the total load does not exceed the inverter's rated power.
  5. Communication Ports (Optional): For lithium batteries with BMS, connect the RS232/RS485 communication cable to the inverter for enhanced monitoring and control.

Warning: Incorrect wiring can cause severe damage to the inverter, batteries, and connected appliances, and poses a risk of electric shock or fire. Always double-check all connections before powering on the system.

6. Operating Instructions

The inverter features a multi-functional LCD panel and intuitive buttons for monitoring and controlling its operation.

6.1 LCD Panel and Navigation

The LCD panel provides real-time system data and operating status. Use the physical buttons to navigate through different program modes and view information.

Multi-functional LCD panel displaying input and output voltage, battery status, and bypass information.

Figure 9: Multi-functional LCD Panel

Key information displayed includes:

  • Input Information (AC voltage, frequency)
  • Output Information (AC voltage, frequency, load percentage)
  • Charging/Discharging Priority
  • Battery Information (Voltage, charge level)
  • Fault Indications and warnings

6.2 Charging Modes

The inverter supports three distinct charging modes:

Diagram showing three input charging modes (Solar, Utility, Hybrid) and four output load modes (UTL, SOL, SBU, SUB).

Figure 10: Charging and Load Output Modes

  • Solar Charging: Prioritizes charging the battery from solar panels.
  • Utility Charging: Charges the battery from the AC utility grid.
  • Hybrid Charging: Combines solar and utility power to charge the battery, optimizing charging efficiency.

6.3 Load Output Modes

The inverter offers four load output modes to manage power distribution to your appliances:

  • UTL Mode (Utility First): Prioritizes power from the utility grid. If utility power fails, it switches to battery/solar.
  • SOL Mode (Solar First): Prioritizes power from solar panels. If solar power is insufficient, it switches to utility or battery.
  • SBU Mode (Solar-Battery-Utility): Prioritizes solar power, then battery power. Utility power is used only when solar and battery power are insufficient.
  • SUB Mode (Solar-Utility-Battery): Prioritizes solar power, then utility power. Battery power is used only when solar and utility power are insufficient.

6.4 Lithium Battery Activation

When connected to compatible lithium batteries, the inverter can automatically activate and initiate charging if the battery runs out, ensuring continuous operation without manual intervention.

7. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your VEVOR Hybrid Solar Inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris.
  • Connection Checks: Annually inspect all electrical connections (battery, solar, AC input/output) for tightness and signs of corrosion. Tighten any loose connections.
  • Environmental Check: Ensure the installation environment remains cool, dry, and well-ventilated.
  • Firmware Updates: Check the VEVOR website for any available firmware updates for your model.

Caution: Always disconnect all power sources (solar and battery) before performing any cleaning or maintenance.

8. Troubleshooting

If you encounter issues with your inverter, refer to the LCD panel for fault indications. Below are general troubleshooting steps:

  • No Power/No Display: Check battery connections and voltage. Ensure the main power switch is ON.
  • Overload Warning: Reduce the connected load. Ensure the total power consumption of your appliances does not exceed the inverter's rated power.
  • Over-Temperature Warning: Check for obstructions around the ventilation openings. Ensure the inverter is in a well-ventilated area.
  • Battery Not Charging: Verify solar panel connections and output. Check utility AC input if using utility charging. Ensure battery type settings are correct on the inverter.
  • Inverter Not Providing AC Output: Check input power sources (solar, utility). Verify battery voltage is within operating range. Check for any fault codes on the LCD.

For persistent issues or complex problems, contact VEVOR customer support.

9. User Tips

  • Monitor the LCD: Regularly check the LCD panel for system status, input/output information, and any fault indications. This can help you identify and address minor issues before they become major problems.
  • Optimize Charging Modes: Experiment with the different charging modes (Solar, Utility, Hybrid) to find the most efficient setup for your specific energy needs and local conditions.
  • Understand Load Modes: Familiarize yourself with the UTL, SOL, SBU, and SUB output modes to effectively manage power distribution to your appliances and prioritize energy sources.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official VEVOR website or contact VEVOR customer service directly. Keep your purchase receipt and model number handy for faster assistance.

© 2024 VEVOR. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?