PowMr POW-LVM3.6M-24V

Contents

PowMr 3.6KW Hybrid Solar Inverter User Manual

Model: POW-LVM3.6M-24V

Brand: PowMr

1. Introduction

This manual describes the assembly, installation, operation, and troubleshooting of the PowMr 3.6KW Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.

The PowMr POW-LVM3.6M-24V is a multi-function inverter/charger that combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It features a comprehensive LCD display for user-configurable settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges for various applications.

1.1 Key Features

  • Pure sine wave inverter output.
  • Configurable input voltage range for home appliances and personal computers via LCD setting.
  • Configurable battery charging current based on applications via LCD setting.
  • Configurable AC/Solar Charger priority via LCD setting.
  • Compatible with mains voltage or generator power.
  • Auto restart while AC is recovering.
  • Overload, over temperature, and short circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • Dual AC inputs and dual AC outputs.
  • Optional WiFi with remote monitoring APP.
PowMr 3.6KW Hybrid Solar Inverter with key features listed

Figure 1: PowMr 3.6KW Hybrid Solar Inverter highlighting key features and supported regions.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION – To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION – Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
  10. One piece of 150A fuse is provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS – This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  12. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

3. Product Overview

The PowMr 3.6KW Hybrid Solar Inverter (Model: POW-LVM3.6M-24V) is designed for efficient solar power management. Below are its physical dimensions and key components.

PowMr 3.6KW Hybrid Solar Inverter with dimensions and key specifications

Figure 2: Inverter dimensions (423x334x110 mm) and key features including 120A MPPT, 4200W Max PV Array Power, and 60-500VDC PV Array MPPT Voltage Range.

3.1 Components

Front, side, and back views of the PowMr Solar Inverter Charger

Figure 3: Various views of the solar inverter charger, showing the display, ventilation, and connection ports.

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons (UP, DOWN, ESC, ENTER)
  6. Power on/off switch
  7. AC input
  8. Main output
  9. Second output
  10. Battery input
  11. PV input
  12. Anti-dust kit
  13. WIFI communication/RS-232 port
  14. Battery communication/RS-485 port
  15. Circuit breaker

4. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these steps carefully.

4.1 Unpacking and Inspection

Before installation, inspect the unit for any damage. The package should contain:

  • The inverter unit x 1
  • User manual x 1

Video 1: Unboxing and initial overview of the PowMr Hybrid Solar Inverter.

4.2 Mounting the Unit

Consider the following points when selecting an installation location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level for easy LCD display readability.
  • Allow a clearance of approximately 20 cm to the sides and 50 cm above and below the unit for proper air circulation and heat dissipation.
  • The ambient temperature should be between 0°C and 55°C for optimal operation.
  • Adhere the unit to the wall vertically.

WARNING: Suitable for mounting on concrete or other non-combustible surfaces only.

Install the unit by screwing two M6 screws. Ensure sufficient space for wiring and heat dissipation.

4.3 Battery Connection

CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. It is recommended to have over-current protection installed even if a disconnect device is not used.

WARNING: All wiring must be performed by qualified personnel.

WARNING: Use appropriate cable for battery connection to ensure system safety and efficient operation. To reduce risk of injury, use the proper recommended cable size:

ModelWire SizeCable (mm²)Torque value (max)
3.6KW/6.2KW1 x 2AWG252 Nm

Follow these steps for battery connection:

  1. Remove insulation sleeve 18 mm for positive and negative conductors.
  2. Put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the system diagram (Figure 4).
  4. Insert the battery wires flatly into the inverter's battery connectors. Tighten bolts with a torque of 2 Nm in a clockwise direction. Ensure correct polarity (+ to + and - to -) and that conductors are tightly screwed. Recommended tool: #2 Pozi Screwdriver.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

CAUTION: Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) is connected to negative (-).

System installation wiring diagram showing connections for solar panels, inverter, battery, AC input, and AC output

Figure 4: Detailed wiring diagram for the hybrid solar inverter system, including generator, utility, solar panels, battery, and AC loads.

Image showing different battery types compatible with the inverter and 120A fast charging

Figure 5: The inverter supports various 24V battery types including GEL, FLD, LI-ion, and USE (User-defined), with a maximum charging current of 120A.

4.4 AC Input/Output Connection

CAUTION: Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is protected from overcurrent.

Recommended AC breaker specifications: 32A for 3.6KW model, 50A for 6.2KW model.

CAUTION: There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.

WARNING: All wiring must be performed by qualified personnel.

WARNING: Use appropriate cable for AC input connection for system safety and efficient operation. To reduce risk of injury, use the proper recommended cable size:

ModelGaugeCable (mm²)Torque Value
3.6KW12 AWG41.2 Nm
6.2KW10 AWG61.2 Nm

Follow these steps for AC input/output connection:

  1. Before making AC input/output connections, open the DC protector or disconnector first.
  2. Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N by 3mm.
  3. Insert AC input wires according to polarities (L=brown or black, N=blue) indicated on the terminal block and tighten the terminal screws.
  4. WARNING: Ensure the AC power source is disconnected before attempting to hardwire it to the unit.
  5. Insert AC output wires according to polarities (L=brown or black, N=blue) indicated on the terminal block and tighten the terminal screws.
  6. Make sure all wires are securely connected.

CAUTION: Appliances like air conditioners require 2-3 minutes to restart. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function. Otherwise, the inverter may trigger an overload fault to protect the appliance, but internal damage may still occur.

4.5 PV Connection

CAUTION: Before connecting to PV modules, install a DC circuit breaker separately between the inverter and PV modules.

WARNING: Use appropriate cable for PV module connection for system safety and efficient operation. To reduce risk of injury, use the proper recommended cable size:

ModelWire SizeCable (mm²)Torque value (max)
3.6KW/6.2KW1 x 12AWG41.2 Nm

PV Module Selection:

When selecting PV modules, consider these parameters:

  • Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
  • Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
INVERTER MODEL3.6KW6.2KW
Max. PV Array Open Circuit Voltage500Vdc
PV Array MPPT Voltage Range60Vdc~450Vdc
Solar panel specifications including Max PV Open-Circuit Voltage and PV Array MPPT Voltage Range

Figure 6: Solar panel specifications and important considerations for PV module selection.

Follow these steps for PV module connection:

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. Put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Check correct polarity of wire connection from PV modules and PV input connectors. Connect positive pole (+) to positive pole (+) and negative pole (-) to negative pole (-). Recommended tool: 4mm blade screwdriver.

4.6 Communication Connection

Wi-Fi Cloud Communication (Option):

Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the "SMARTESS" APP from the APP store and refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be shown on your mobile phone APP or computer webpage.

GPRS Cloud Communication (Option):

Use the supplied communication cable to connect to the inverter and GPRS module, then apply external power to the GPRS module. Download the APP from the APP store and refer to the "GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be shown on your mobile phone APP or computer webpage.

Battery Communication:

The communication between the battery and the inverter can be realized through the battery communication interface, allowing the inverter and lithium battery to exchange information.

Remote monitoring and control via the SMARTESS app with optional WiFi module

Figure 7: Remote monitoring and control via the "SMARTESS" app. The WiFi module and GPRS data need to be purchased separately.

5. Operation

5.1 Power ON/OFF

Once the unit is properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

5.2 Operation and Display Panel

The operation and display panel on the front of the inverter includes three indicators, four function keys, and an LCD display, providing operating status and input/output power information.

LCD Display and Function Keys:

LCD display and function keys on the inverter

Figure 8: LCD display and function buttons (UP, DOWN, ESC, ENTER) for navigating settings.

LED IndicatorColorMessage
INV/ACGreenSolid On: Output is powered by utility in Line mode.
Flashing: Output is powered by battery or PV in battery mode.
CHGGreenSolid On: Battery is fully charged.
Flashing: Battery is charging.
FAULTRedSolid On: Fault occurs in the inverter.
Flashing: Warning condition occurs in the inverter.
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

LCD Display Icons:

LCD display icons for input source, output, battery, load, and mode operation

Figure 9: LCD display icons and their meanings for monitoring inverter status.

The LCD display information can be switched by pressing "UP" or "DOWN" keys. Information includes input voltage, frequency, PV voltage, charging current, charging power, battery voltage, output voltage, output frequency, load percentage, load in Watt, load in VA, DC discharging current, and main CPU Version.

5.3 Operating Mode Description

The inverter supports various operating modes, including Standby, Line, and Grid-Tie operation. The LCD display will show different information depending on the current mode and power conditions.

Hybrid Power System diagram showing connections to solar, generator, utility, battery, and home appliances

Figure 10: Hybrid Power System illustrating how the inverter integrates solar, grid, generator, and battery power for home appliances.

Charging Modes:

Charging modes: Solar First, Solar and Utility, Only Solar Charging

Figure 11: Different charging modes to optimize energy cost: Solar First, Solar and Utility, and Only Solar Charging.

  • Solar First: Solar energy will charge the battery as the first priority. Utility will charge the battery only when solar energy is not available.
  • Solar and Utility: Solar energy and utility will charge the battery at the same time.
  • Only Solar Charging: Solar energy will be the only charger source, no matter if utility is available or not.

Batteryless Mode:

The inverter supports a batteryless mode, allowing it to power loads directly from PV/AC without a battery connected.

Inverter supporting batteryless mode, powering loads from PV/AC without battery

Figure 12: The inverter can operate in batteryless mode, powering loads directly from solar or AC input.

6. Maintenance

6.1 Clearance and Maintenance for Anti-Dust Kit

Every inverter comes with an anti-dust kit installed from the factory. This kit helps keep dust out of your inverter and increases product reliability, especially in harsh environments. The inverter automatically detects this kit and adjusts its internal thermal sensor.

To clean the anti-dust kit:

  1. Loosen the screw in a counterclockwise direction on the top of the inverter.
  2. Remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and dustproof case.
  4. After cleaning, re-assemble the dust-kit back to the inverter.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

7. Troubleshooting

This section provides solutions for common problems encountered during the operation of the inverter. If errors persist after following these steps, please contact your local dealer or service center.

ProblemLCD/LED/BuzzerExplanation / Possible CauseWhat to do
Unit shuts down automatically during startup process.LCD/LEDs and buzzer active for 3 seconds, then off.The battery voltage is too low (<1.91V/Cell).1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. The battery voltage is far too low. (<1.4V/Cell).
2. Internal fuse tripped.
1. Contact repair center for replacing the fuse.
2. Re-charge battery.
3. Replace battery.
Input voltage displayed as 0 on LCD, green LED flashing.Input protector is tripped.Check if AC breaker is tripped and AC wiring is connected well.
Mains exist but unit works in battery mode.Green LED is flashing.Insufficient quality of AC power (Shore or Generator).1. Check if AC wires are too thin and/or too long.
2. Check if generator (if applied) is working well or if input voltage range setting is correct (UPS Appliance).
Green LED is flashing.Set "Solar First" as the priority of output source.Change output source priority to Utility first.
When unit is turned on, internal relay switches on and off repeatedly.LCD display and LEDs are flashing.Battery is disconnected.Check if battery wires are connected well.
Fault code 07Overload error. Inverter is overloaded 110% and time is up.Reduce the connected load by switching off some equipment.
Fault code 05Output short circuited.Check if wiring is connected well and remove abnormal load.
Fault code 02Temperature of internal converter component is over 120°C.
Internal temperature of inverter component is over 100°C.
Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.
Buzzer beeps continuously and red LED is on.Fault code 03Battery is over-charged.
The battery voltage is too high.
Return to repair center.
Check if specifications and quantity of batteries meet requirements.
Fault code 01Fan fault.Replace the fan.
Fault code 06/58Output abnormal (Inverter voltage below 190Vac or higher than 260Vac).1. Reduce the connected load.
2. Return to repair center.
Fault code 08/09/53/57Internal components failed.Return to repair center.
Fault code 51Over current or surge.Restart the unit. If error persists, return to repair center.
Fault code 52Bus voltage is too low.Restart the unit. If error persists, return to repair center.
Fault code 55Output voltage is unbalanced.Restart the unit. If error persists, return to repair center.

Warning Indicator:

Warning CodeWarning EventAudible AlarmIcon Flashing
01Fan is locked when inverter is on.Beep three times every second01 icon
03Battery is over-chargedBeep once every second03 icon
04Low batteryBeep once every second04 icon
07OverloadBeep once every 0.5 second07 icon
10Output power deratingBeep twice every 3 seconds10 icon
15PV energy is low.Beep twice every 3 seconds15 icon
E9Battery equalizationNoneE9 icon
6PBattery is not connectedNone6P icon

8. Specifications

Detailed technical specifications for the PowMr 3.6KW Hybrid Solar Inverter (POW-LVM3.6M-24V).

8.1 Line Mode Specifications

Parameter3.6KW6.2KW
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage100Vac
Low Loss Voltage90Vac±5V (UPS); 90Vac±5V (Appliances)
Low Loss Return Voltage95Vac±5V (UPS); 95Vac±5V (Appliances)
High Loss Voltage145Vac±5V
High Loss Return Voltage140Vac±5V
Max AC Input Voltage150Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

Output Power Derating:

When AC input voltage drops to 100V, the output power will be derated.

8.2 Inverter Mode Specifications

Parameter3.6KW6.2KW
Rated Output Power3.6KW6.2KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation100/105/110/115/120Vac±5%
Output Frequency50Hz / 60Hz
Peak Efficiency93%
Overload Protection3s@≥150%; 5s@101%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage24Vdc48Vdc
Cold Start Voltage23.0Vdc46.0Vdc
Low DC Warning Voltage (@load < 50%)22.0Vdc44.0Vdc
Low DC Warning Voltage (@load ≥ 50%)21.0Vdc42.0Vdc
Low DC Warning Return Voltage (@load < 50%)22.5Vdc45.0Vdc
Low DC Warning Return Voltage (@load ≥ 50%)22.0Vdc44.0Vdc
Low DC Cut-off Voltage (@load < 50%)20.5Vdc41.0Vdc
Low DC Cut-off Voltage (@load ≥ 50%)20.0Vdc40.0Vdc
High DC Recovery Voltage32Vdc62Vdc
High DC Cut-off Voltage33Vdc63Vdc
No Load Power Consumption45W50W

8.3 Two Load Output Power

Parameter3.6KW6.2KW
Full Load3600W6200W
Maximum Main Load3600W6200W
Maximum Second Load (battery model)1200W2066W
Main Load Cut Off Voltage26VDC52VDC
Main Load Return Voltage27VDC54VDC

8.4 Charge Mode Specifications

Utility Charging Mode:

Parameter3.6KW6.2KW
Charging Algorithm3-Step
AC Charging Current (Max)80Amp (@V_I/P=100 Vac)
Bulk Charging Voltage (Flooded Battery)29.258.4
Bulk Charging Voltage (AGM / Gel Battery)28.256.4
Floating Charging Voltage27Vdc54Vdc

MPPT Solar Charging Mode:

Parameter3.6KW6.2KW
Max. PV Array Power4200W6500W
Nominal PV Voltage240Vdc360Vdc
PV Array MPPT Voltage Range60Vdc~500Vdc
Max. PV Array Open Circuit Voltage500Vdc
Max Charging Current (AC charger plus solar charger)120Amp120Amp

8.5 Grid-Tie Operation

Parameter3.6KW6.2KW
Nominal Output Voltage100/105/110/115/120VAC
Feed-in Grid Voltage Range90~150VAC
Feed-in Grid Frequency Range49~51±1Hz/59~61±1Hz
Nominal Output Current30A51.7A
Power Factor Range>0.99
Maximum Conversion Efficiency (DC/AC)97%

8.6 General Specifications

Parameter3.6KW6.2KW
Safety CertificationCE
Operating Temperature Range-10°C to 50°C
Storage temperature-15°C~ 60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm423x334x110423x334x110
Net Weight, kg910

8.7 Approximate Back-up Time Table

The following tables provide approximate backup times based on load and battery capacity. Note that actual backup time depends on battery quality, age, and type.

3.6KW Model:

Load (W)Backup Time @ 24Vdc 100Ah (min)Backup Time @ 24Vdc 200Ah (min)
3004491100
600222525
900124303
120095227
150068164
180056126
210048108
24003594
27003174
32002867
36002560
42002253

6.2KW Model:

Load (W)Backup Time @ 48Vdc 100Ah (min)Backup Time @ 48Vdc 200Ah (min)
5006131288
1000268613
1500158402
2000111271
250090215
320076182
350065141
400050112
450044100
50004090
62003680

9. User Tips

Based on common inquiries and user feedback, here are some tips for optimal use:

  • Battery Compatibility: This inverter is compatible with various 24V lithium or lead-acid batteries. Ensure your battery type is correctly configured in the LCD settings for optimal charging and discharge performance.
  • Remote Monitoring: Utilize the optional WiFi module and the "SMARTESS" app for convenient remote monitoring of your inverter's status and performance. This can help in proactive troubleshooting and system optimization.
  • Regular Maintenance: Adhere to the recommended monthly cleaning schedule for the anti-dust kit to maintain efficient cooling and prolong the lifespan of your inverter, especially in dusty environments.
  • Wiring Verification: Always double-check all wiring connections (battery, AC input/output, PV) for correct polarity and secure fastening to prevent faults and ensure safe operation.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your authorized PowMr dealer or the service center where you purchased the product. Refer to the original purchase documentation for specific warranty terms and conditions.

A detailed user manual in PDF format is available for download: PowMr Hybrid Inverter User Manual (PDF).


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.