1. Introduction and Overview
The NJTY T-61 series insulation tester is a professional instrument designed for measuring insulation resistance, absorption ratio (DAR), polarization index (PI), AC voltage, and low resistance. It incorporates advanced large-scale integrated circuit technology and professional software, offering a wide measuring range, high output power, and multiple selectable output voltage levels (100V, 250V, 500V, 1000V, 2500V for T6125). The device features a large, gray-white backlit LCD display for clear readability, is easy to carry and operate, and provides accurate, reliable, and stable performance with strong anti-interference capabilities.
Its robust, shockproof, dustproof, and moisture-proof construction makes it an ideal testing instrument for various electrical equipment, including transformers, generators, motors, power capacitors, power cables, and lightning arresters.

2. Safety Information
WARNING: To avoid electric shock or personal injury, please read and understand all safety information before using this instrument. Improper use can result in severe injury or death.
- Always wear appropriate personal protective equipment (PPE) when working with electrical systems.
- Do not use the instrument if it appears damaged or if the test leads are damaged.
- Ensure the instrument is turned off and disconnected from any power source before installing or replacing batteries.
- Do not operate the instrument in wet environments or during electrical storms.
- Verify the correct test voltage setting before performing any insulation resistance measurements.
- Always discharge the circuit under test after measurement, especially high voltage tests. The instrument features an automatic discharge function.
- Do not exceed the maximum input ratings for any function.
- Keep hands and fingers behind the finger guards on the test leads during use.
3. Product Features
- Insulation Resistance Measurement: Wide range from 0.01MΩ to 200.0GΩ.
- Multiple Test Voltages: Selectable output voltages including 100V, 250V, 500V, 1000V, and 2500V (for T6125 model).
- Absorption Ratio (DAR) and Polarization Index (PI) Measurement: For assessing insulation quality over time.
- AC Voltage Measurement: Capable of measuring AC voltage.
- Low Resistance Measurement: For continuity and low resistance checks.
- Automatic Discharge Function: Safely discharges residual voltage after insulation tests.
- Data Hold Function: Freezes the displayed measurement for easy reading.
- Over-Range Alarm: Alerts the user when measurements exceed the selected range.
- Large Backlit LCD Display: Ensures clear visibility in various lighting conditions.
- Automatic Shutdown: Powers off after 30 minutes of inactivity to conserve battery life.
- Durable Construction: Shockproof, dustproof, and moisture-proof design with an all-round anti-fall plastic shell.
- Dual Power Supply Mode: Operates on 8 x 1.5V AA batteries or an external 12V power adapter.
4. Package Contents
Please check the package carefully upon receipt to ensure all items are present and undamaged:
- 1 x NJTY Insulation Resistance Tester (T6125 or T6110 model)
- 1 x Pair of Test Leads (Red and Black)
- 1 x External Power Plug (5.5mm)
- 2 x Alligator Clips (Red and Black)
- 1 x Cloth Bag for storage and transport
- 1 x User Manual (English)

5. Product Layout and Components

- High Voltage Output Black Negative Jack: Connects to the negative test lead for high voltage insulation tests.
- High Voltage Output Red Positive Jack: Connects to the positive test lead for high voltage insulation tests.
- Resistor Red Positive Jack: Connects to the positive test lead for low resistance and AC voltage measurements.
- Resistive Black Negative Jack: Connects to the negative test lead for low resistance and AC voltage measurements.
- Soft Silicone Material Shell: Provides protection against drops and impacts.
- 12V Power Input Jack: For connecting an external 12V DC power adapter (5.5mm plug).
- LCD Display: Large backlit screen for displaying measurement results and settings.
- Test Button: Initiates the selected measurement (e.g., insulation resistance test).
- Data Hold Button (HOLD): Freezes the current reading on the display.
- Backlit Button: Toggles the LCD backlight on/off.
- DAR (Absorption Ratio) / PI (Polarization Index) Button: Initiates DAR/PI measurements.
- Gear Rotary Switch (OFF/Voltage Selection/Function Selection): Used to power the device on/off and select measurement functions (e.g., 250V, 500V, 1000V, 2500V, ACV, Ω).
6. Specifications
| Parameter | Specification |
|---|---|
| Model | T6110 / T6125 (Optional) |
| Material | ABS |
| Insulation Test Measurement Range | 0.01MΩ ~ 200.0GΩ |
| Insulation Test Test Voltage (T6125) | 100V, 250V, 500V, 1000V, 2500V |
| Insulation Test Output Voltage Accuracy | ±10% |
| Insulation Test Short Circuit Test Current | Approximately 2 mA |
| Automatic Discharge Function | Yes |
| Storage Temperature | -20℃ ~ 60℃ |
| Working Conditions Temperature | 0℃ ~ 40℃ |
| Altitude | Up to 2000m |
| Relative Humidity | 40% ~ 75% |
| Power Supply | 8 x 1.5V AA batteries (Not included) or External 12V DC adapter |
| Item Size | 179 x 133 x 70mm / 7.04 x 5.23 x 2.75in |
| Item Weight | 570g / 1.25lb (without batteries) |
7. Setup
7.1 Battery Installation
- Ensure the device is powered OFF by turning the Gear Rotary Switch to the 'OFF' position.
- Locate the battery compartment cover on the back of the instrument.
- Open the battery compartment cover.
- Insert 8 x 1.5V AA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Close the battery compartment cover securely.
7.2 External Power Connection
For extended use or when batteries are low, an external 12V DC power adapter (with a 5.5mm plug) can be used.
- Ensure the device is powered OFF.
- Connect the external power adapter plug to the 12V Power Input Jack (6) on the side of the instrument.
- Plug the adapter into a suitable power outlet.
7.3 Connecting Test Leads and Alligator Clips
- For Insulation Resistance, DAR, or PI measurements: Connect the red test lead to the High Voltage Output Red Positive Jack (2) and the black test lead to the High Voltage Output Black Negative Jack (1). Attach the red alligator clip to the red test lead and the black alligator clip to the black test lead.
- For AC Voltage or Low Resistance measurements: Connect the red test lead to the Resistor Red Positive Jack (3) and the black test lead to the Resistive Black Negative Jack (4). Attach the red alligator clip to the red test lead and the black alligator clip to the black test lead.
- Ensure all connections are firm and secure before proceeding with any measurements.
8. Operating Instructions
8.1 Power On/Off
Turn the Gear Rotary Switch (12) from 'OFF' to the desired measurement function (e.g., a voltage setting for insulation test, ACV, or Ω) to power on the device. To power off, turn the switch back to 'OFF'.
8.2 Insulation Resistance Measurement
- Connect the test leads as described in Section 7.3 (for Insulation Resistance).
- Turn the Gear Rotary Switch (12) to the desired test voltage (e.g., 250V, 500V, 1000V, 2500V).
- Ensure the circuit under test is de-energized and isolated.
- Connect the alligator clips to the circuit points where insulation resistance is to be measured.
- Press and hold the Test Button (9). The display (7) will show the insulation resistance value.
- Release the Test Button (9) to stop the test. The instrument will automatically discharge the circuit.
8.3 Absorption Ratio (DAR) and Polarization Index (PI) Measurement
- Perform an Insulation Resistance Measurement as described in Section 8.2.
- While the insulation test is active (Test Button pressed), press the DAR/PI Button (11).
- The instrument will automatically perform the DAR and PI calculations based on timed insulation resistance readings.
- The results will be displayed on the LCD. Refer to the full user manual for detailed interpretation of DAR and PI values.
8.4 AC Voltage Measurement
- Connect the test leads as described in Section 7.3 (for AC Voltage).
- Turn the Gear Rotary Switch (12) to the 'ACV' position.
- Connect the alligator clips across the points where AC voltage is to be measured.
- The AC voltage reading will be displayed on the LCD (7).
8.5 Low Resistance Measurement
- Connect the test leads as described in Section 7.3 (for Low Resistance).
- Turn the Gear Rotary Switch (12) to the 'Ω' position.
- Connect the alligator clips across the component or circuit path where low resistance is to be measured.
- The resistance reading will be displayed on the LCD (7).
8.6 Data Hold Function
During any measurement, press the Data Hold Button (HOLD) (10) to freeze the current reading on the LCD. Press it again to release the hold function and resume live readings.
8.7 Backlight Control
Press the Backlit Button (10) to turn the LCD backlight on or off, improving visibility in low-light conditions.
8.8 Automatic Shutdown
The instrument will automatically power off after approximately 30 minutes of inactivity to conserve battery life. To restart, turn the Gear Rotary Switch (12) to 'OFF' and then back to the desired function.
9. Maintenance
9.1 Cleaning
Wipe the instrument casing with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is off and disconnected from all power sources before cleaning.
9.2 Battery Replacement
When the low battery indicator appears on the LCD, replace all 8 x 1.5V AA batteries as described in Section 7.1. Do not mix old and new batteries or different types of batteries.
9.3 Storage
When not in use for extended periods, remove the batteries to prevent leakage. Store the instrument in its cloth bag in a cool, dry place, away from direct sunlight and extreme temperatures.
10. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Instrument does not power on. | Dead or incorrectly installed batteries; external power not connected/faulty. | Check battery polarity and replace if necessary. Verify external power adapter connection and functionality. |
| No reading or 'OL' (Overload) displayed during test. | Test leads not properly connected; circuit open; measurement range exceeded. | Ensure test leads are securely connected. Check for open circuits. Select a higher test voltage or range if applicable. |
| Inaccurate readings. | Poor test lead contact; external interference; instrument fault. | Ensure good contact with the circuit. Move away from strong electromagnetic fields. If problem persists, contact support. |
| Backlight not working. | Backlight function off; low battery. | Press the Backlit Button. Replace batteries if low. |
11. User Tips
- For critical insulation measurements, perform both DAR and PI tests to get a more comprehensive assessment of insulation health.
- Always ensure the test leads are clean and free from damage to maintain accurate readings and ensure safety.
- When measuring insulation resistance, allow sufficient time for the reading to stabilize, especially for large capacitive loads.
- Utilize the Data Hold function when working in awkward positions where viewing the display directly is difficult.
12. Warranty and Support
This product is manufactured to high-quality standards. For any technical assistance, warranty claims, or support inquiries, please contact the seller or the manufacturer directly. Please retain your purchase receipt as proof of purchase.