1. Product Overview
The ZEEWEII DSO1C81 is a compact, handheld digital oscilloscope featuring an 80MHz bandwidth and a 250MSa/s real-time sampling rate. It integrates multiple functions including a frequency meter, pulse counter, FFT analysis, ZOOM mode, cursor measurement, and a built-in signal generator. Designed for ease of use, it's suitable for various electrical measurement tasks, from probe calibration to DIY circuit debugging.

2. Package Contents
Please check the package contents upon receipt to ensure all items are present and undamaged:
- DSO1C81 Digital Oscilloscope Unit
- P6100 Probe
- USB Cable (Type-C)
- Instruction Manual
- Product Box

3. Setup and Charging
3.1 Initial Charging
The DSO1C81 features a built-in lithium battery. Before first use, it is recommended to fully charge the device. Connect the oscilloscope to a 5V power source using the provided Type-C USB cable. The device supports fast charging up to 1.2A, and a full charge typically provides 5-6 hours of continuous use.

3.2 Connecting the Probe
Connect the P6100 probe to the BNC probe connection socket on the top of the oscilloscope. Ensure a secure connection. The two small tabs next to the BNC connector are the output of the signal generator.

4. Operating Instructions
The DSO1C81 features a 2.8-inch LCD display with 320*240 resolution and intuitive button controls for various functions.
4.1 Basic Controls
The front panel includes several buttons for operation:
- OK Auto: Automatic waveform adjustment.
- Run/Stop: Start or pause waveform acquisition.
- Menu: Access the main menu for settings and advanced features.
- Func: Function button, often used in conjunction with other buttons.
- s / ns: Adjust time base (seconds / nanoseconds).
- mV↑ / V↓: Adjust vertical sensitivity (millivolts / volts).
- Arrow Buttons: Navigate menus, adjust parameters, and move cursors.

4.2 Advanced Features
The DSO1C81 offers a range of advanced measurement and analysis capabilities:
- Frequency Meter: Accurately measures frequencies from 10Hz to 30MHz. Utilizes FPGA for high-precision 6-bit hardware frequency measurement, useful for crystal oscillators (e.g., 32.768kHz).
- Pulse Counter: Counts the number of pulses in a signal.
- FFT (Fast Fourier Transform): Performs spectrum analysis using a base-4 butterfly algorithm for faster calculation and higher resolution. Supports measuring FFT frequency with a cursor.
- ZOOM Mode: Allows displaying two waveforms at different time bases simultaneously. The screen is divided into two sections: a large time base waveform (upper) and a small time base waveform (lower). This is useful for bus timing and amplitude modulation signal analysis.
- Persistence: Displays previous waveforms to observe signal changes over time (options: none, 1s, ∞).
- Roll Mode: Continuous display of slow-moving signals.
- Single Trigger: Captures a single event waveform.
- Save Picture: Saves the current screen display.
- Cursor Measurement: Supports X/Y cursors. Manually move cursors to measure time differences (between left and right cursors) and voltage differences (between upper and lower cursors).
- Signal Generator: Built-in generator capable of outputting sine, square, and triangular waves. The amplitude is fixed at 3V, and the frequency is adjustable from 1Hz to 2MHz. Ideal for probe calibration and circuit debugging.





5. Maintenance and Care
To ensure the longevity and optimal performance of your DSO1C81 oscilloscope, follow these maintenance guidelines:
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the oscilloscope in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Care: Avoid fully discharging the lithium battery frequently. If storing for extended periods, charge the battery to about 50% and recharge every few months.
- Physical Protection: The device features an ABS shell for durability and comfortable silicone keys. Avoid dropping the device or exposing it to excessive force.
6. Troubleshooting
If you encounter issues with your DSO1C81, refer to the following common problems and solutions:
- Device does not power on: Ensure the battery is charged. Connect the USB cable to a power source and try again.
- No waveform displayed: Check probe connection. Ensure the input signal is within the oscilloscope's voltage range. Adjust vertical sensitivity (mV↑/V↓) and time base (s/ns) settings. Use the 'OK Auto' function.
- Distorted waveform: Verify probe compensation. Ensure proper grounding. Check for external interference.
- Signal generator not working: Ensure the function is enabled in the menu and parameters are set correctly. Check the connection to the output tabs.
- Buttons unresponsive: Try restarting the device. If the issue persists, contact customer support.
7. Specifications
| Feature | Specification | Feature | Specification |
|---|---|---|---|
| Model | DSO1C81 | Coupling | AC/DC |
| Channel | 1 | Auto mode | Yes |
| Screen | 2.8 inch | Measure item | 14 types |
| Sampling rate | 250MSa/s | DC error | ±3% |
| Bandwidth | 80MHz | Freq-meter | 10Hz~30MHz |
| Equivalent sample | 500M | Save picture | Yes |
| Rise time | <4ns | Pulse counter | Yes |
| Storage depth | 480Kbit (60Kpts) | FFT | Yes |
| Impedance | 1MΩ | Generator waveforms | Sin/Square/Triangular... |
| Time base | 5ns - 10s | Generator voltage | 3V |
| Vertical sensitivity (X1) | 10mV/div~10V/div | Generator frequency | 1Hz~1MHz |
| Vertical sensitivity (X10) | 100mV/div~100V/div | Dimensions | 12*8*3.2cm |
| Max voltage (X1) | 40V | Resolution | 320*240 |
| Max voltage (X10) | 220V | Language | Chinese/English |
| Trigger mode | Auto/Normal/Single | Charging | Type-C 5V |
| Trigger type | Rise/Fall | Material | ABS |
| Scan mode | YT/XY/Roll | Battery Included | Yes |
| Persistence | None/1s/∞ | Hign-concerned Chemical | None |

8. User Tips
Here are some tips to enhance your experience with the DSO1C81 oscilloscope:
- Probe Compensation: Always perform probe compensation before making critical measurements to ensure accurate readings. This typically involves connecting the probe to a calibration signal (often a square wave output on the oscilloscope itself) and adjusting the probe's compensation trimmer until a perfect square wave is displayed.
- Understanding Triggering: Mastering the trigger settings (Auto, Normal, Single, Rise/Fall) is crucial for stable waveform display. 'Auto' is good for general signals, 'Normal' for stable display of repetitive signals, and 'Single' for capturing non-repetitive events.
- Utilizing Zoom Mode: When analyzing complex signals or specific parts of a waveform, use the ZOOM mode to get a detailed view without losing the overall context.
- Signal Generator for Testing: The built-in signal generator is excellent for testing circuits or calibrating other equipment. Experiment with different waveforms and frequencies.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official ZEEWEII website. Keep your proof of purchase for warranty claims.