1. Introduction
The ELECTESLA ES-PC300 LCD Pressure Transmitter is designed for precise measurement of pressure in various media including water, gas, oil, and other liquids. It utilizes an imported diffused silicon sensor, high-performance circuit processor, and temperature compensation technology to convert pressure into standard electrical signals (4-20mA, 0-5V, 0-10V, RS485). These signals can then be used by secondary instruments for measurement, indication, and process regulation. The device features an LCD display for clear readings and unit adjustment.
2. Safety Precautions
- This product uses a diffused silicon oil-filled core. Improper use may cause explosion accidents. Measuring oxygen is strictly prohibited.
- Do not measure media that are incompatible with the material in contact with the transmitter.
- No modifications or changes are allowed on the device.
- When measuring steam or other high-temperature media, ensure the medium temperature does not exceed the transmitter's operating temperature. Install a cooling device if necessary.
- This product is weak current equipment; wire it separately from strong current cables.
- Ensure the power supply voltage meets the transmitter's requirements and the pressure source's high pressure is within the transmitter's range.
- During pressure measurement, increase and release pressure slowly to avoid sudden high pressure or product damage.
- This product is not explosion-proof. Do not use it in explosion-proof areas.
3. Specifications
The ES-PC300 pressure transmitter is designed with robust features for reliable performance.
3.1. Product Features
- Sensor: German imported diffused silicon sensor for fast response, accurate, and stable measurement.
- Design: Adopts diaphragm isolation technology, integrated core, and wide voltage power supply.
- Accuracy: 0.5% F.S. (default), 0.2% F.S.
- Output: 4-20mA, 0-5V, 0-10V, RS485.
- Power Supply: 12V/24VDC, 12V-24VDC, 5VDC (customizable).
- Thread Size: M20*1.5, G1/4, G1/2, G3/8, NPT1/2, NPT1/4 (customizable).
- Overload Capacity: 150% F.S.
- Response Time: ≤10ms.
- Protection Grade: IP65 (Waterproof and dustproof).
- Stability: ±0.2% F.S./year.
- Temperature Drift: 0.05% F.S./°C (-10°C to 65°C).
- Housing: 304 stainless steel (customizable SS316).
- Connector: Hirschmann Connectors.
- Display: LCD display with units in Kpa, Mpa, bar, mbar, psi, $KG/Fcm^2$, mm, m.
- Anti-interference: Digital circuit board with strong anti-interference capability.
- Pressure Shock Resistance: 3mm pilot hole for 1.5 times instant pressure shock resistance.
3.2. Technical Parameters Table
3.3. Pressure Range and Thread Size Selection
4. Installation
4.1. General Installation Guidelines
- Installation requires no pressure and no power supply.
- Install in locations where temperature gradient changes are minimal.
- For gases, if the measuring range is less than 0.03Mpa, mount vertically to ensure accuracy. Other media can be mounted at any angle.
- In hydraulic systems, mount the pressure connections upwards for easy gas venting.
- If the transmitter is installed with the pressure connection facing upwards or sideways, ensure no liquids flow outside the transmitter housing to prevent moisture and dirt from blocking atmospheric outlets near the electrical connection.
- Keep threaded connection edges free of dust and dirt.
- It is recommended to install a pressure shut-off valve in front of the measurement point for easy access and removal. This also helps reduce pressure shock during initial installation.
- For harsh environments (e.g., lightning strikes, over-voltage), protect the transmitter with lightning and over-voltage protection at the distribution box or between the power supply and the transmitter.
- Select appropriate sealing fittings and sealing positions based on the measuring medium and input pressure. Ensure thread length is greater than the bottom thread depth for an effective end gasket seal, and less than the base thread depth for an effective root gasket seal.
4.2. Product Dimensions
5. Wiring Diagrams
Proper wiring is crucial for the correct operation of the pressure transmitter. Refer to the diagrams below for electrical connections.
5.1. No Display Version Wiring (Current Output)
6. Operating Instructions
The ES-PC300 features an LCD display for easy monitoring and configuration. The display supports multiple units and can be freely adjusted.
6.1. LCD Display Features
- Two-wire passive working mode, 4-bit LCD display.
- Supports zero clearing, small signal removal, filter settings, and other functions for ease of use.
- Pressure, temperature, liquid level, and 12 other types of units can be selected.
- Equipped with over-current, over-voltage, short-circuit, and reverse connection protection. The 24VDC power supply will not be damaged even if the load is short-circuited.
- Strengthened anti-interference design for harsh industrial environments with electromagnetic interference.
6.2. Working Principle
The pressure sensor operates on the principle of a Wheatstone bridge diffused on a single crystal silicon wafer. The measured medium (gas or liquid) applies pressure, causing a change in the resistance of the bridge wall (piezoresistive effect). This generates a differential voltage signal, which is then converted into a standard analog or digital signal corresponding to the pressure range via a dedicated amplifier.
7. Maintenance
- Before cleaning, ensure the pressure transmitter is relieved of pressure and disconnected from power.
- Do not touch the diaphragm with objects to avoid damage.
- Wipe the surface of the transmitter with a soft, damp cloth.
- The product is enclosed with a silicone gel process inside, making it waterproof and moisture-proof to ensure a long service life of components.
8. Troubleshooting
- Sudden Pressure Shock: Cavitation, liquid hammer, and peak pressure can occur in filling systems, especially when quickly closing valves or starting/closing pumps. The sensor is equipped with a pulse buffer to mitigate these issues. Note that after installing a pulse buffer, the frequency of the dielectric pulse may decrease below 30Hz.
- Inaccurate Readings: Ensure proper vertical mounting for gas measurements below 0.03Mpa. Verify that the measuring medium is compatible with the transmitter's contact material.
- No WiFi Connectivity: This pressure transmitter does not support WiFi connectivity. It provides reliable signal output via 4-20mA, 0-5V, 0-10V, or RS485.
- Power/Signal Issues: Check all wiring connections against the provided diagrams. Ensure the power supply voltage is correct and stable.
9. User Tips
- Users have reported this product to be very effective and reliable for its intended purpose.
- The ES-PC300 with LCD display is confirmed to support specific configurations like 0-250 mbar range with 4-20mA output, making it versatile for various applications.
10. Warranty and Support
For any questions, technical guidance, or support, please contact the manufacturer directly. Technical support is provided for the life of the product.
Contact Information:
- WhatsApp: +8619356149608
- Email: whitney@jinqu-electric.com
A PDF version of the user manual is available for download: User Manual (PDF)
11. Product Video Demonstration
Watch this video for a visual overview and demonstration of the pressure transmitter.