1. Introduction
The Surecom SW-112HF is a highly accurate RF meter designed for measuring Forward Power, Reflected Power, and Voltage Standing Wave Ratio (V.S.W.R.) in radio frequency systems. It features an LED backlight and an analogue meter for clear and easy readings, along with convenient controls for straightforward operation. This manual provides detailed instructions for the proper setup, operation, and maintenance of your SW-112HF meter.
2. Safety Information
- Ensure the device is powered within the specified DC +5V ~12V range.
- Do not exceed the maximum power rating of 120 Watts.
- Always make sure all connections are secure before transmitting.
- This device is not water resistant. Avoid exposure to moisture or liquids.
- Do not attempt to open or modify the device, as this may void the warranty and cause damage.
3. Package Contents
Please check the package for the following items:
- 1 x Surecom SW-112HF V.S.W.R. & Power Meter
- 1 x USB to 5.5/2.1mm power cable
- 1 x User Manual (this document)
4. Product Overview
The Surecom SW-112HF meter features an intuitive layout for ease of use. Familiarize yourself with the components shown below:
Figure 1: Front Panel Controls
- Meter Display: Analog meter for V.S.W.R., Forward Power (FW), and Reflected Power (RW) readings.
- M. LOCK / ON Switch: Power switch for the unit.
- CAL Knob: Used for calibration during V.S.W.R. measurement.
- FW CAL Switch: Selects Forward Power for calibration.
- SWR Switch: Selects V.S.W.R. measurement mode.
- WATT Switch: Selects Power (Watt) measurement mode.
- 12W / 120W Switch: Selects the power range (12 Watts or 120 Watts).
Figure 2: Rear Panel Connections
- DC5V-12V Input: Power input port for the meter.
- ANT Connector (SO-239): Connects to your antenna.
- TX Connector (SO-239): Connects to your radio (transceiver).
5. Setup
To set up your Surecom SW-112HF meter, follow these steps:
Figure 3: Typical Setup Diagram
- Connect the SWR Meter: The S.W.R. meter must be placed in-line between your radio (TX) and the antenna (ANT). Use a coaxial feedline to connect the radio's output to the TX connector on the meter. Use another coaxial feedline (or a short test jumper, not included, max. 40 cm) to connect the ANT connector on the meter to your antenna system.
- Power Connection: Connect the provided USB to 5.5/2.1mm cable to the DC5V-12V input on the rear of the meter. Connect the USB end to a suitable USB power source (e.g., a USB wall adapter, power bank, or computer USB port). The meter's LED backlight will illuminate when powered.
- Check Connections: Ensure all coaxial connections are tight and secure to prevent signal loss or interference.
6. Operating Instructions
6.1. V.S.W.R. Measurement
Follow these steps to measure the V.S.W.R. of your antenna system:
Figure 4: VSWR Measurement Steps
- Step 1: Calibration
- Set the M. LOCK / ON switch (2) to the "ON" position.
- Set the WATT switch (6) to the "SWR" position.
- Set the FW CAL switch (5) to the "CAL" position.
- Set your radio transceiver to transmit mode (e.g., by pressing the PTT key on the microphone).
- Slowly turn the CAL control knob (3) clockwise until the meter pointer is at the "CAL" position (full scale deflection) on the meter display.
- Step 2: Read SWR
- While still transmitting, set the FW CAL switch (5) to the "SWR" position.
- The meter will now indicate the SWR ratio on the meter display.
6.2. Power Measurement (Forward and Reflected)
To measure Forward (FW) and Reflected (RW) power:
- Set the M. LOCK / ON switch (2) to the "ON" position.
- Set the WATT switch (6) to the "WATT" position.
- Select the appropriate power range using the 12W / 120W switch (7). Choose 12W for lower power transmissions and 120W for higher power transmissions.
- Set the FW CAL switch (5) to the "FW" position to read Forward Power.
- Set the FW CAL switch (5) to the "RW" position to read Reflected Power.
- Press the PTT key on your radio to transmit and read the corresponding power value on the meter display.
6.3. Interpreting SWR Readings
Understanding your SWR reading is crucial for antenna performance and equipment protection:
Figure 5: SWR Reading Caution
- 1.5 -> 2.0: Your antenna is acceptably tuned and should work fine.
- 2.0 -> 3.0: Your SWR reading is slightly high. It shouldn't immediately damage your radio, but you should try to tune your antenna to bring down your SWR reading for optimal performance.
- Above 3.0 or more: Your antenna isn't tuned acceptably and could damage your equipment. Cease transmission and adjust your antenna immediately.
7. Specifications
| Feature | Specification |
|---|---|
| Power Range | 0 - 120 Watts (Maximum) |
| Frequency Range | 1.5 - 60 MHz |
| S.W.R. Range | 1:1 ~ ∞ |
| V.S.W.R. Measurement Power Requirement | > 4 Watts |
| LED Backlight DC Power Input | DC +5V ~ 12V |
| Input/Output Impedance | 50 Ohm |
| Input/Output Connectors | SO-239 |
| Dimensions (W x H x D, including connector) | 88mm x 59mm x 80mm |
| Weight | 270g |
| USB Cable Length | 100cm |
8. Maintenance
- Cleaning: Use a soft, dry cloth to clean the exterior of the meter. Do not use abrasive cleaners or solvents.
- Storage: Store the meter in a cool, dry place away from direct sunlight and extreme temperatures when not in use.
- Connector Care: Keep the SO-239 connectors clean and free from dust or corrosion to ensure optimal performance.
9. Troubleshooting
- Meter Not Powering On: Ensure the USB power cable is securely connected to both the meter and a functional DC +5V ~12V power source. Check the M. LOCK / ON switch is in the 'ON' position.
- No Readings or Inaccurate Readings:
- Verify all coaxial connections between the radio, meter, and antenna are secure.
- Ensure the radio is transmitting sufficient power (greater than 4 Watts for SWR measurement).
- Confirm the correct switches (WATT, FW CAL, 12W/120W) are selected for the desired measurement.
- Recalibrate the SWR meter as per the operating instructions.
- Stuck Meter Pointer: If the analog meter pointer appears stuck upon initial use, apply power to the unit and operate it by transmitting briefly. In some cases, the pointer may free itself after a short period of use.
10. User Tips
- This meter is well-suited for basic SWR and power measurements, making it a good value for amateur radio enthusiasts looking for essential HF band diagnostics.
- If the meter pointer seems stuck initially, try powering on the device and transmitting briefly. Some users have reported that the pointer frees up after a few hours of operation.
11. Frequently Asked Questions (FAQ)
- Q: Does this meter work for VHF and UHF frequencies?
- A: No, the Surecom SW-112HF is designed for a frequency range of 1.5-60 MHz, which covers the High Frequency (HF) bands. It is not suitable for VHF (Very High Frequency) or UHF (Ultra High Frequency) operation.
- Q: Can I use this meter for 7.050 MHz or 3.500 MHz?
- A: Yes, both 7.050 MHz and 3.500 MHz fall within the specified frequency range of 1.5-60 MHz, so the meter will function correctly for these frequencies.
12. Warranty and Support
For warranty information and technical support, please refer to the seller's policies or contact the point of purchase. Keep your proof of purchase for any warranty claims.