eletechsup IO33H01

IO33H01 AC110V 220V Power-ON Delay Relay Switch Module User Manual

Adjustable Disconnect Delay Controller

1. Introduction

This manual provides detailed instructions for the safe and effective use of the eletechsup IO33H01 AC110V 220V Power-ON Delay Relay Switch Module. This module is designed to provide a delayed power-off function for various electrical appliances, ensuring controlled operation and enhanced safety. Please read this manual thoroughly before installation and operation.

2. Product Overview and Features

The IO33H01 is a versatile power-on delay relay switch module that allows you to set a specific delay time after which the power supply to a connected appliance will be disconnected. It features a compact design and is suitable for a wide range of applications.

Key Features:

  • Adjustable delay time with 16 selectable modes (from 1 minute to 480 minutes).
  • Supports AC 110V-220V power supply.
  • Maximum output current of 7A (up to 10A peak).
  • Equipped with an LED indicator (PWR) to display working status (constant light for active, flashing for delay over).
  • High-quality, dust-proof, and flame-retardant shell (for models with shell).
  • Suitable for controlling incandescent lamps (up to 1400W), energy-saving lamps (up to 300W), exhaust fans, motors, air coolers, cooling fans, germicidal lamps, humidifiers, heaters, etc.

3. Safety Information

WARNING: Improper installation or operation can lead to electric shock, fire, or damage to the device. Always follow these safety guidelines:

  • Live Wiring Prohibited: Never perform wiring or adjust DIP switches while the module is powered on. Always disconnect the main power supply before making any connections or changes.
  • Correct Neutral Wire Connection: The neutral wire connection is critical. Reversing it will result in no output from the yellow wire. Live wiring is strictly prohibited.
  • Ensure all connections are secure and insulated to prevent short circuits.
  • Do not exceed the specified maximum load for connected appliances.
  • Install the module in a dry environment, away from moisture and extreme temperatures.
  • If you are unsure about any wiring or installation steps, consult a qualified electrician.

4. Specifications

ParameterValue
Brandeletechsup
ModelIO33H01
Power SourceAC 110-220V
Output VoltageAC 110-220V
Output Current7A (MAX 10A)
Working Power Consumption43mA
Maximum Standby Power Consumption12mA
Control Channels1 output
Control Power (Incandescent Lamps)1400W (maximum)
Control Power (Energy-saving Lamps)300W (maximum)
Control Power (Motor Class)1000W (maximum)
Control Power (Electric Heating Type)2000W (maximum)
TheoryTime Relay
Contact LoadHigh Power
Working Temperature-25℃ to 85℃
Working Humidity5% to 95%RH
CertificationCE
Protect FeatureEpoxy
Dimensions (without shell)44 × 28 × 1.6mm
Weight (without shell)19.1 grams
Dimensions (with shell)57 × 35 × 20mm
Weight (with shell)29 grams
Wire Length50mm

Product Views:

IO33H01 Delay Relay Module (Only Board)
IO33H01 Delay Relay Module (Only Board)
IO33H01 Delay Relay Module with Protective Shell
IO33H01 Delay Relay Module with Protective Shell
Dimensions and weight of the IO33H01 module
Dimensions and weight of the IO33H01 module

5. Installation and Wiring

Before proceeding with installation, ensure the main power supply is completely disconnected to prevent electric shock.

Wiring Instructions:

  • Red Wire: Connect to the input 220V fire wire (Live).
  • Green Wire: Connect to the input 220V neutral line.
  • Yellow Wire: Connect to the output 220V fire wire (Live) of the appliance.
  • Important: The neutral wire cannot be reversed. Reversing it will result in no output from the yellow wire. Live wiring is strictly prohibited.

Wiring Diagrams:

Basic wiring diagram for IO33H01 module
Basic wiring diagram showing input (red, green) and output (yellow) connections. Note: Neutral wire cannot be reversed.
Common wiring diagram for IO33H01 with power plug and electrical appliance
Common wiring diagram illustrating connection to a power plug and an electrical appliance. Applicable for Electric Lamps ≤100W, Motor Class ≤1000W, Electric Heating Type ≤2000W.
Detailed wiring diagram for IO33H01 showing AC power supply and load
Detailed wiring diagram showing the AC 85-265V power supply, a regular switch, and the load (lights/fans etc.) connected to the IO33H01 module. Delay time is adjustable from 1-480 minutes.
Common wiring diagram for double switch control with IO33H01
Common wiring diagram for double switch control. The electrical appliance will be turned off after a delay following power failure. The zero line connects directly to the delayer and light fixture without going through any switch. For single open double control switches (e.g., 86 Switch/Rocker Switch), the live wire goes straight to the light wire for continuous operation when the mechanical switch is ON. When the mechanical switch is OFF, the live wire connects to the red wire, powering the delay device, which then disconnects the equipment after the delay.

6. Operating Instructions

The IO33H01 module functions as a delayed power-off device. Once the set delay time elapses, the power supply to the connected appliance is stopped.

Operating Steps:

  1. Set Delay Time: Before powering on, set the desired delay time using the DIP switches (refer to Section 7). No live settings are allowed.
  2. Power On: After verifying all wiring is correct and secure, apply power to the module. The LED indicator (PWR) will illuminate constantly, indicating the module has started its operation.
  3. Delay Completion: Once the set delay time has elapsed, the module will stop providing power to the connected appliance. The LED indicator (PWR) will then begin to flash, signaling that the delay is over and the power is off.

Additional Notes:

  • Early Shutdown: If you need to turn off the appliance before the delay time expires, simply disconnect the main power supply to the module.
  • Restarting Delay: To initiate a new delay cycle, you must re-power the module after it has been turned off.

7. Delay Time Setting

The IO33H01 module offers 16 different delay modes, adjustable via a DIP switch. Always ensure the module is powered off before adjusting the DIP switches.

Setting Procedure:

  1. Disconnect Power: Ensure the module's main power supply is completely disconnected.
  2. Refer to Table: Consult the "Io33h01 Setting Delay Time 16 Modes Reference Table" below to identify the DIP switch configuration for your desired delay time.
  3. Adjust DIP Switches: Toggle the red DIP switches (labeled 1, 2, 3, 4) on the module according to the pattern shown in the reference table for your chosen delay.
  4. Verify and Power On: After setting, double-check your wiring and then re-apply power to the module.

Delay Mode Reference Table:

Io33h01 Setting Delay Time 16 Modes Reference Table
This table illustrates the 16 available delay settings (1 minute to 480 minutes) and their corresponding DIP switch configurations. Black squares indicate the switch is in the 'ON' position.

8. Maintenance

The IO33H01 module is designed for reliable operation with minimal maintenance. To ensure its longevity and proper function:

  • Keep the module clean and free from dust and debris.
  • Avoid exposing the module to excessive moisture, direct sunlight, or extreme temperatures.
  • Periodically check wiring connections to ensure they remain secure.
  • Do not attempt to open or repair the module yourself, as this may void any potential warranty and poses a safety risk.

9. Troubleshooting

If you encounter issues with your IO33H01 module, consider the following common troubleshooting steps:

  • Module not powering on / LED not lighting up:
    • Check the main power supply connection.
    • Verify input voltage is within the AC 110-220V range.
    • Ensure wiring is correct and secure.
  • Appliance not turning off after delay:
    • Confirm the delay time is correctly set using the DIP switches (refer to Section 7).
    • Check the output wiring to the appliance.
    • Ensure the appliance's power consumption does not exceed the module's maximum control power.
  • Yellow output wire has no output:
    • This often indicates the neutral wire has been reversed. Disconnect power immediately and re-check your wiring according to the diagrams in Section 5.
  • Module behaves erratically:
    • Disconnect power, wait a few seconds, and then re-apply power to reset the module.
    • Ensure the operating environment is within specified temperature and humidity ranges.

If problems persist after attempting these steps, please contact the seller or a qualified technician for assistance.

10. User Tips

Based on common usage scenarios, here are some tips for optimizing your experience with the IO33H01 module:

  • Pre-test Setup: Before final installation, it's advisable to temporarily wire the module with a low-power test load (e.g., a small lamp) to confirm the delay settings and basic functionality.
  • Labeling: For complex setups, consider labeling the wires and the module itself to easily identify connections and settings.
  • Ventilation: While the module has a protective feature, ensuring good ventilation around it can help dissipate heat, especially when controlling higher-wattage appliances.
  • Consider the "With Shell" Option: If the module is to be installed in an exposed area or where it might be subject to dust or accidental contact, the version with the protective shell offers enhanced durability and safety.

11. Support

For technical support, questions, or concerns regarding your eletechsup IO33H01 module, please contact the seller directly through the platform where you purchased the product. Provide your order details and a clear description of the issue for prompt assistance.

Documents - eletechsup – IO33H01