1. Introduction
The DIANQI AHC30A and AHC30B are advanced digital programmable timer switches designed for precise control of electrical devices. These devices can be used for timing control or countdown functions for various applications such as street lamps, neon lights, advertising signboards, door head lights, rice cooker timing, electric fans, TV, computers, water pumps, and air conditioning units. They can also be integrated into school or factory bell ringing systems. The AHC30A model features 1 Normally Open (NO) and 1 Normally Closed (NC) contact, while the AHC30B features 1 Normally Open (NO) contact.
2. Safety Information
- Always disconnect power before installation or maintenance to prevent electric shock.
- Ensure wiring is performed by a qualified electrician and complies with all local electrical codes.
- Do not exceed the maximum rated current of 30A for the relay.
- This device is designed for indoor use. Avoid installation in humid, corrosive, or high metal content gas environments, or where it may be exposed to water or oil, as this can affect performance and safety.
- Verify the correct voltage model (12V, 24V, 110V, 220V, 240V AC/DC) before connecting to a power source.
3. Package Contents
- 1 x AHC30A or AHC30B Digital Programmable Timer Switch
- 1 x Instruction Manual (this document)
4. Specifications
| Feature | Specification |
|---|---|
| Brand Name | DIANQI |
| Model Numbers | AHC30A, AHC30B |
| Theory | Electronic |
| Use | Timer Switch |
| Working Voltage | AC 12V, 24V, 110V, 220V, 240V; DC 12V, 24V, 48V |
| Max Current of Relay | 30A (Resistive Load) |
| Hysteresis | <= 1 sec/day (at 25°C) |
| Minimum Interval | 1 minute |
| ON/OFF Operations | 18 ON & 18 OFF (18 plans) |
| Power Consumption | 7.5VA (max) |
| Service Life | Mechanical: 10^7, Electrical: 10^5 |
| Output Mode | AHC30A: 1 NO & 1 NC; AHC30B: Active Output (1 NO) |
| Countdown Range | 59 seconds - 99 minutes 59 seconds |
| Switching Contact | 1 changeover switch |
| Power Reserve | 3 years (lithium battery for memory backup) |
| Ambient Temperature | -10°C to +40°C |
| Ambient Humidity | 35-85% RH |
| Weight | Approx. 150g |
| Dimensions (L x W x H) | 64.5mm x 35.5mm x 86.5mm |
| Certification | CE |
Dimensions

Figure 1: Dimensions of the AHC30A/AHC30B Digital Timer Switch.
Internal Battery

Figure 2: Location of the replaceable battery for power reserve. The battery provides power backup for the timer's memory and clock function during power outages.
5. Installation and Initial Setup
5.1 Mounting
The AHC30A/AHC30B timer switch is designed for DIN rail mounting. Securely attach the device to a standard DIN rail in your electrical panel. Note that DIN rails are typically not included with the timer switch.

Figure 3: AHC30A/AHC30B timer switch mounted on a DIN rail (DIN rail not included).
5.2 Wiring
Refer to the wiring diagrams below for proper connection. Ensure the load capacity does not exceed the rated 30A. For loads exceeding 4.5kW, use AC contactors (e.g., CJX1, CJT1) as shown in the advanced wiring diagrams.
Important Note on Models:
- AHC30A (1NO1NC): This model acts as a switch and is used for controlling circuits. It cannot be directly loaded.
- AHC30B (1NO): This model can be directly loaded.

Figure 4: Detailed wiring diagrams for AHC30A and AHC30B models, including direct load and contactor-assisted connections for various voltages.
5.3 Initial Power-Up and Reset
- When first using the timer switch, press the RESET button (usually a small recessed button requiring a pointed object).
- If the screen is not displaying after reset, ensure the internal battery is charged. Connect the timer to power for at least 12 hours, then try pressing the RESET button again.
6. Operation and Programming
6.1 Setting Local Time
- To adjust the week, press the D+ button.
- To adjust the hour, press the H+ button.
- To adjust the minute, press the M+ button.
- To switch between 12-hour and 24-hour modes: The first time, the switch is in 24h mode. To switch to 12h mode, press D+ for 5 seconds. To return to 24-hour mode, the LCD will display AM, then press D+ for 5 seconds.
6.2 Programming ON/OFF Schedules (18 Plans)
The timer supports up to 18 ON/OFF programs per week.
- Press the P button to enter programming mode. The display will show '1 ON'.
- Press H+ and M+ to set the desired hour and minute for the first ON event.
- Press D+ to select the day(s) of the week for this ON event. You can select individual days or a combination (e.g., MO TU WE TH FR SA SU for every day).
- Press P again. The display will show '1 OFF'.
- Press H+ and M+ to set the desired hour and minute for the first OFF event.
- Press D+ to select the day(s) of the week for this OFF event.
- Repeat steps 2-6 for additional ON/OFF programs (up to 18).
- After setting all desired programs, press P to exit programming mode. If you don't need all 18 programs, press the G button to skip to the end.
6.3 Manual Override
- Press the MANUAL button to temporarily turn the output power ON or OFF.
- When 'ON AUTO' or 'AUTO OFF' is displayed, the timer is in automatic timing state. The timing program will not execute immediately but will activate at the next scheduled ON/OFF time.
- To check current settings, press the MANUAL button. To cancel an extra timing program group, press MANUAL until '---' is displayed.
6.4 Countdown Setting
- To enter countdown mode, press and hold the G button, then press and hold G again for 3 seconds. The display will show '00:00'.
- Press and hold G, then use H+ to adjust hours and M+ to adjust minutes for the countdown time.
- Press MANUAL to start the countdown function.
- To reset the countdown to zero, press the G button.
- To end the countdown function, press and hold the G button, then press G again for 3 seconds.
6.5 Three-Ring Setting (for Bell/Alarm)
This function allows for a brief ON/OFF cycle at a specific time, useful for applications like an electric bell. In the timing setting, set the opening and closing time to be the same (e.g., 8:00 ON and 8:00 OFF). The timer will then activate for approximately 10 seconds at that time.
7. Troubleshooting
- Lid falls off: Reinstall the lid by carefully aligning and snapping it back into place.
- Screen not displaying: Press the RESET button. If it still doesn't display, charge the internal battery by connecting the timer to power for 12 hours, then try pressing RESET again.
- Timer not responding or erratic behavior: Ensure the operating environment is within specified temperature and humidity ranges. Avoid humid, corrosive, or high metal content gas environments, and exposure to oil or water.
- Programs not executing: Verify that the timer is in 'AUTO' mode (displaying 'ON AUTO' or 'AUTO OFF'). If '---' is displayed, it means a program group was canceled. Re-enter the desired programs.
- Three and four functions cannot be used at the same time.
8. User Tips
- The internal lithium battery provides power reserve for the clock and programmed settings during power outages, ensuring your schedules are maintained.
- Always double-check your wiring connections before applying power to prevent damage to the timer or connected devices.
- When setting weekly programs, ensure you select all desired days (MO TU WE TH FR SA SU) if you intend for the program to run daily.
- For optimal performance and longevity, install the timer in a dry, clean environment away from direct heat sources or corrosive substances.
9. Maintenance
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Do not use abrasive cleaners or solvents.
- The internal battery is replaceable. If the power reserve function degrades significantly, the battery may need to be replaced by a qualified technician.
10. Warranty and Support
For any technical assistance or support inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty claims.