DIANQI AHC30A/AHC30B

AHC30A/AHC30B Digital Programmable Time Switch Instruction Manual

Model: AHC30A/AHC30B | Brand: DIANQI

1. Introduction

The DIANQI AHC30A/AHC30B is a new type of Din Rail mounted digital programmable time switch designed for weekly 7-day control. It features 18 programmable ON/OFF plans and is suitable for various applications such as street lamp control, neon light, advertising signboard lighting, door head light, rice cooker timing, electric fan timing, water pump timing, and electric bell timing. The AHC30A model offers 1NO1NC contacts, while the AHC30B offers 1NO contacts.

2. Safety Information

  • Ensure all wiring is performed by a qualified electrician and complies with local electrical codes.
  • Disconnect power before installation or maintenance to prevent electric shock.
  • Do not exceed the maximum load capacity of 30A for the relay. For loads exceeding 25A, an external contactor should be used.
  • Avoid operating the device in humid, corrosive environments, or areas with high metal content gas, as this may affect normal operation and device lifespan.
  • This product is an electronic device; avoid strong impacts or vibrations.

3. Product Overview

The time switch features a digital display, control buttons (P, D+, H+, M+, RESET, MANUAL), and terminal connections for input and output. It is designed for Din Rail mounting.

Dimensions

Dimensions of the AHC30A/AHC30B Digital Time Switch

Figure 1: Product Dimensions (Height: 86.5mm, Width: 35.5mm, Depth: 64.5mm)

Models

  • AHC30A: Features 1 Normally Open (NO) and 1 Normally Closed (NC) contact. Used for controlling circuits; cannot be directly loaded.
  • AHC30B: Features 1 Normally Open (NO) contact. Can be directly loaded.
AHC30A (1NO1NC) and AHC30B (1NO) Digital Time Switches

Figure 2: AHC30A (left) and AHC30B (right) models

4. Setup

Initial Checks

  1. Lid Reinstallation: If the protective lid falls off, carefully reinstall it by aligning the tabs and pressing firmly.
  2. Screen Display: If the screen is not displaying, press the "RESET" button using a pointed object (e.g., a pen tip).
  3. Battery Charge: If the screen still doesn't display after resetting, charge the device for 12 hours and then try step 2 again. The device contains a replaceable lithium battery for power reserve.
Image showing the replaceable battery compartment on the time switch

Figure 3: Replaceable battery location

Wiring Instructions

The wiring method depends on the model (AHC30A or AHC30B) and your actual needs. Refer to the diagrams below for correct connections. Ensure the load capacity does not exceed 25A; for higher loads, use an external contactor.

Wiring diagrams for AHC30A (1NO1NC) and AHC30B (1NO) digital time switches

Figure 4: Wiring Diagrams. AHC30A (1NO1NC) on left, AHC30B (1NO) on right.

Visual Setup Guide

For a visual demonstration of initial setup, resetting, and wiring, please watch the following video:

Video 1: Initial setup, reset, and wiring demonstration.

5. Operating Instructions

Initial Operation and Time Setting

  1. When using the time switch for the first time, press the RESET key.
  2. The time switch defaults to 24-hour mode. To switch to 12-hour mode, press D+ for 5 seconds. To return to 24-hour mode, the LCD will display "AM" and then press D+ for 5 seconds.
  3. To adjust the local time:
    • Press D and then D+ to adjust the week.
    • Press H+ to adjust the hour.
    • Press M+ to adjust the minute.

Programming (18 Plans)

The device supports up to 18 ON/OFF programs (plans) per week. Follow these steps to set your programs:

StepKeyProgramming
1PSet the time of the first opening.
2H+/M+Display (1NO----), enter the time of first opening, adjust hours, adjust minutes.
3D+Choose a certain day of the week. If you want to open it every day, select all of them (MO TU WE TH FR SA SU).
4PSet the time of the first close.
5D+Display (1OFF----), enter the first shutdown time, adjust hours, adjust minutes.
6D+Choose a certain day of the week. If you want to close every day, select all of them (MO TU WE TH FR SA SU).
RepeatSteps 2-6Repeat for up to 18 plans.
7PEnd programming.

Note: If you do not need all 18 settings, press the "C/R" key to exit programming.

Checking and Exiting Programming

  • Press the MANUAL button to check your programmed settings.
  • If you do not need an extra timing program group, press the MANUAL button to cancel it. The screen will display "--:--".
  • After installing the wiring, press C/R to return to clock mode, then press MANUAL. The red light indicates the output load is energized.

Manual ON/OFF

  • Press MANUAL to display "ON" or "OFF" to temporarily turn the output power ON or OFF.
  • When "ON AUTO" or "AUTO OFF" is displayed, and "AUTO" is in the middle, the device is in automatic timing state. The timing will not execute immediately but will activate at the next programmed time node.

Countdown Setting

  1. To enter countdown mode, press D+, H+, and M+ simultaneously for 3 seconds. The display will show "0:00".
  2. Set the countdown time using D+ (days), H+ (hours), and M+ (minutes).
  3. To start the countdown function, press MANUAL.
  4. To reset to halfway, press the RESET button. To return to "0", press the P button.
  5. To end the countdown, press the P button, and then press the P button again for 3 seconds.

Ring Setting (for electric bell applications)

In the time setting mode, if the opening and closing times are the same (e.g., ON at 8:00 and OFF at 8:00), the time control switch will activate for 10 seconds. This is useful for electric bells, which will ring for 10 seconds and then stop.

6. Maintenance

  • The time switch contains a replaceable lithium battery for power reserve. If the battery needs replacement, ensure the device is disconnected from power.
  • Clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Regularly check wiring connections to ensure they are secure.

7. Troubleshooting

  • Screen not displaying: First, ensure the protective lid is correctly installed. Then, press the "RESET" button. If it still doesn't display, charge the device for 12 hours and try resetting again.
  • Timing not executing: Ensure the device is in "ON AUTO" or "AUTO OFF" mode with "AUTO" displayed in the middle. Verify that the programmed times are correctly set and do not cross over (e.g., an ON time should precede an OFF time within a logical sequence).
  • Inaccurate timing: The device has a hysteresis of less than or equal to 1 second per day at 25°C. Significant temperature fluctuations may affect accuracy slightly.
  • Output load issues: Ensure the connected load does not exceed the rated capacity of 30A. For inductive loads or loads exceeding 25A, an external contactor is recommended.

8. Specifications

FeatureSpecification
Working VoltageAC220V, AC110V, DC12V, DC24V, DC48V
Hysteresis≤ 1 sec/day (at 25°C)
Minimum Interval1 minute
ON/OFF Operation18 ON & 18 OFF
Power Consumption≤ 7.5 VA (max)
Service Life (Mechanical)107 operations
Service Life (Electrical)105 operations
Load Capacity (Resistive)30A
Switching Contact1 Changeover Switch
Power Reserve3 years (lithium battery)
Ambient Temperature-10°C to +40°C
Ambient Humidity35-85% RH
WeightApprox. 150g
CertificationCE

9. User Tips

  • Always double-check your wiring against the provided diagrams before applying power to avoid damage to the device or connected appliances.
  • When setting multiple programs, ensure there are no overlapping or conflicting ON/OFF times to prevent unexpected behavior.
  • If the device is not responding as expected, a quick reset using the "RESET" button can often resolve minor glitches.
  • For long-term reliability, consider using an external contactor for high-current or inductive loads, even if within the 30A limit, to protect the internal relay.

10. Warranty and Support

For any technical assistance, warranty claims, or further inquiries, please contact the seller or manufacturer directly. Ensure you have your purchase details and model number readily available.


Related Documents - THC15A

Preview THC15A Electronic Time Switch User Manual - Oktimer
User manual for the Oktimer THC15A weekly programmable electronic time switch. Provides details on installation, technical specifications, operating instructions, and troubleshooting for this DIN rail mountable timer.
Preview THC15A Weekly Programmable Digital Time Switch - Technical Specifications and Operation
Detailed information on the THC15A weekly programmable digital time switch, including technical specifications, connection diagrams, operating instructions, and dimensions. Features 16 on/off settings, lithium battery backup, and auto time correction.
Preview THC15A Weekly Programmable Timer: Installation and Operation Guide
Comprehensive guide for the THC15A Weekly Programmable Timer, covering DIN rail installation, technical specifications, connection diagrams, dimensions, and operating instructions for setting daily and weekly programs.
Preview THC15A Weekly Programmable Timer - User Manual and Technical Data
Detailed technical specifications, connection diagrams, dimensions, and operating instructions for the THC15A Weekly Programmable Timer. Includes programming steps in English, Malay, and Chinese.
Preview TM-615 Weekly Programmable Timer - User Manual and Technical Specifications
Detailed user manual and technical specifications for the TM-615 Weekly Programmable Timer, including installation, operation, and technical data for this digital electronic time switch.
Preview CN101 Weekly Programmable Timer User Manual
Detailed user manual for the CN101 weekly programmable electronic time switch, covering installation, technical specifications, operating instructions, and troubleshooting for AC 220V, 16A applications.

Ask a question about this manual