1. Introduction
The BSIDE U6 is a new generation smart True RMS DC/AC 600A Fork Open-Jaw digital clamp meter. Designed for professional electricians, engineers, electronic enthusiasts, and general home use, it offers a wide range of intelligent and professional measurement functions, including an infrared thermometer. Its open-jaw design facilitates convenient current testing and maintenance. The device features an EBTN color large HD LCD display for clear readings and supports innovative dual power supply modes for extended operation.

Figure 1: BSIDE U6 Digital Clamp Meter
Key Features:
- Professional DC/AC 600A Clamp Meter Ammeter with infrared thermometer.
- Maximum display of 9999 Counts.
- EBTN Color Large HD LCD display for enhanced readability.
- True RMS and Auto/Manual Range functionality.
- Dual power supply: Built-in rechargeable battery (USB charging) and 2x 1.5V AA batteries (not included).
- Smart mode for ease of use.
- VFC/VFD (Variable Frequency Control/Drive) frequency conversion voltage test.
- Oversized body design for safer testing.
- Integrated test lead placement design for portability and storage.
- Professional voltage detector with adjustable sensitivity.
- Auto power off, low battery indication, and built-in flashlight.
- CATIII 600V high safety rating.
2. Package Contents
Please check the package carefully to ensure all items are present and undamaged:
- 1 x BSIDE U6 Electronic Tester Clamp Meter
- 1 x Upgrade Test Leads (Red and Black)
- 2 x Lithium Batteries (Rechargeable, if included in specific kit)
- 1 x USB Charging Cable
- 1 x Quality Carrying Case
- 1 x Screwdriver
- 1 x User Manual (this document)
- 1 x Color Box

Figure 2: BSIDE U6 Package Contents
3. Setup and Battery Installation
3.1 Power Supply Options
The BSIDE U6 supports two power supply modes:
- Built-in Rechargeable Battery: The device comes with a built-in rechargeable battery that can be charged via the provided USB cable.
- Replaceable AA 1.5V Dry Batteries: For extended use or as a backup, two 1.5V AA dry batteries (not included in all kits) can be installed.

Figure 3: Dual Power Supply Modes
3.2 Installing/Replacing AA Batteries
- Locate the battery compartment cover on the back of the device.
- Use the provided screwdriver to loosen the screw securing the battery cover.
- Remove the cover.
- Insert two 1.5V AA dry batteries, ensuring correct polarity (+/-).
- Replace the battery cover and tighten the screw.
Note: If using the rechargeable battery, ensure it is charged before first use. The device can be charged via a standard USB power source.
Video 1: Product Unboxing and Battery Installation Demonstration. This video shows the unboxing of the BSIDE U6, its accessories, and the process of installing AA batteries.
4. Operating Instructions
4.1 Device Overview and Controls
Familiarize yourself with the main components and buttons of the BSIDE U6:

Figure 4: BSIDE U6 Labeled Components
- Power Button: Turns the device ON/OFF.
- SEL/AUTO Button: Selects measurement modes or activates auto-ranging.
- A~ Button: Activates AC/DC current measurement.
- VFC Button: Activates VFC (Variable Frequency Control) mode for voltage/current measurements. Also functions as a flashlight switch.
- Infrared Temperature Button: Activates infrared temperature measurement.
- COM Terminal: Common input for test leads.
- INPUT Terminal: Input for test leads for voltage, resistance, capacitance, diode, and continuity measurements.
- Non-contact Voltage Sensor: For NCV (Non-Contact Voltage) detection.
- Current Sensing Zone (Open Jaw): For non-contact current measurement.
- LCD Screen: Displays measurement readings and mode indicators.
4.2 Basic Operation
- Power On/Off: Press the Power button to turn the meter on. Press and hold to turn it off.
- Mode Selection: Use the SEL/AUTO button to cycle through different measurement functions (e.g., Voltage, Resistance, Capacitance, Diode, Continuity). The display will indicate the active mode.
- Auto Ranging: The meter typically operates in auto-ranging mode, automatically selecting the appropriate range for the measurement.
- Flashlight: Press the VFC button briefly to turn the flashlight on or off.
4.3 Measurement Functions
4.3.1 DC/AC Current Measurement (Open Jaw)
The open-jaw design allows for convenient non-contact current measurement up to 600A.
- Press the A~ button to enter current measurement mode.
- Place the open jaw around a single conductor (not a bundle of wires) through which the current is flowing.
- The display will show the AC or DC current reading.

Figure 5: Automatic Current and Voltage Testing
4.3.2 Infrared Temperature Measurement
The integrated infrared thermometer allows for non-contact temperature readings.
- Press the Infrared Temperature button.
- Point the infrared temperature testing sensor area towards the object whose temperature you wish to measure.
- The temperature will be displayed on the screen.

Figure 6: Infrared Temperature Test
4.3.3 DC/AC Voltage Measurement
To measure voltage, connect the test leads to the COM and INPUT terminals.
- Connect the black test lead to the COM terminal and the red test lead to the INPUT terminal.
- Select the appropriate voltage mode (DC or AC) using the SEL/AUTO button.
- Touch the test probes to the points where you want to measure voltage.
- The display will show the voltage reading.

Figure 7: Voltage Measurement Examples
4.3.4 Resistance, Capacitance, Diode, and Continuity Measurement
These functions also use the test leads connected to COM and INPUT.
- Connect the black test lead to the COM terminal and the red test lead to the INPUT terminal.
- Use the SEL/AUTO button to select the desired mode (Resistance, Capacitance, Diode, or Continuity).
- Resistance: Touch the probes to the component.
- Capacitance: Ensure the capacitor is discharged, then touch the probes to its terminals.
- Diode: Touch the probes to the diode terminals.
- Continuity: Touch the probes to the circuit points. A beeper will sound if resistance is less than 30Ω.

Figure 8: Component Measurement Examples
4.3.5 VFC/VFD Test
The VFC (Variable Frequency Control) function is designed to accurately measure voltage and current in circuits driven by variable frequency drives (VFDs) or other non-sinusoidal waveforms.
- Press the VFC button to activate VFC mode.
- Proceed with AC voltage or current measurement as described above. The meter will compensate for the non-sinusoidal waveform.

Figure 9: VFC Test in action
4.3.6 NCV (Non-Contact Voltage) and Live Wire Check
The NCV sensor allows for quick detection of AC voltage without direct contact.
- To use NCV, hold the top part of the meter (where the non-contact voltage sensor is located) near a live AC voltage source. The meter will indicate the presence of voltage through visual and/or audible alerts.
- For Live Wire Check, use the test leads in the appropriate mode (often indicated by 'LIVE' on the display).
5. Maintenance
5.1 General Care
- Keep the device clean and dry. Use a soft, damp cloth for cleaning; do not use abrasive cleaners or solvents.
- Store the meter in its carrying case when not in use to protect it from dust and physical damage.
- Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
5.2 Battery Maintenance
- If using replaceable AA batteries, remove them if the device will not be used for an extended period to prevent leakage.
- For the built-in rechargeable battery, charge it regularly to maintain its lifespan, even if not in frequent use.
- The low battery indicator will alert you when the battery needs charging or replacement.
5.3 Test Lead Storage
The BSIDE U6 features a convenient design for storing test leads directly on the device, enhancing portability and preventing loss.

Figure 10: Test Lead Storage Design
6. Troubleshooting
If you encounter issues with your BSIDE U6, refer to the following common problems and solutions:
- Device does not power on:
- Check if the rechargeable battery is charged. Connect the USB charging cable and allow it to charge.
- If using AA batteries, ensure they are correctly installed with the right polarity and are not depleted. Replace if necessary.
- Inaccurate readings:
- Ensure test leads are securely connected and not damaged.
- Verify that the correct measurement mode is selected for the task.
- For current measurements, ensure only a single conductor is within the open jaw.
- Check for environmental interference (e.g., strong magnetic fields).
- Display is dim or unreadable:
- The battery might be low. Charge the rechargeable battery or replace AA batteries.
- Ensure the screen is clean and free from smudges.
- No continuity beep:
- Ensure the continuity mode is selected.
- The resistance might be above the 30Ω threshold for the beeper to activate.
If the problem persists after trying these steps, please contact customer support for further assistance.
7. Specifications
The following table details the technical specifications of the BSIDE U6 Digital Clamp Meter:

Figure 11: BSIDE U6 Detailed Specifications
| Function | Range | Resolution | Accuracy |
|---|---|---|---|
| DC Voltage | 0-620V (DC Mode) 0.5-620V (Auto Mode) | 0.001V | ±(0.8%+3) |
| AC Voltage | 0-620V (AC Mode) 0.5-620V (Auto Mode) 0-620V (VFC Mode) | 0.001V 0.001V 0.1V | ±(1.2%+5) ±(1.2%+5) ±(4.0%+3) |
| Resistance | 0-10.00MΩ | 0.1Ω | ±(1.2%+3) |
| Capacitance | 0.5µF-1000µF 1000µF-10.00mF | 0.1µF 0.1µF | ±(3.5%+8) ±(4.5%+10) |
| Current | 1-600A (DC) 1-600A (AC, 40-200Hz) 1-600A (VFC, 40-200Hz) | 0.1A 0.1A 0.1A | ±(2.5%+5) ±(2.5%+5) ±(4.0%+5) |
| Frequency | 10-1000Hz | 1Hz | ±(2.0%+10) |
| Infrared Temperature | -20℃~0℃ (-4℉~32℉) 0℃~400℃ (32℉~752℉) | 0.1℃ (0.1℉) 0.1℃ (0.1℉) | ±(3.0%+2℃/℉) ±(2.5%+3℃/℉) |
| The temperature | 0-50℃ | 1℃ (1℉) | ±2℃ (2℉) |
| Continuity | If the resistance ≤ 30Ω the buzzer sounds | ||
| Diode | Measure diodes within 2.0V | ||
| V-Alert | Live wire check | ||
| Auto power off | 5 minutes | ||
| Flashlight | Yes | ||
| Power | 2 x AA Nickel-metal hydride battery or Alkaline battery (or built-in rechargeable) | ||
| Size | 210 x 63.7 x 33 mm | ||
| Weight | 216 g | ||

Figure 12: True RMS Test Feature Explanation
8. User Tips
- Clarity of Display: The EBTN color LCD display is designed for readability in various lighting conditions. If you find it difficult to read, ensure the backlight is on and check battery levels.
- Open Jaw Convenience: Utilize the open-jaw feature for quick and safe current measurements without needing to break the circuit. Remember to isolate a single conductor for accurate readings.
- Dual Power Advantage: Take advantage of the dual power supply. Use the rechargeable battery for regular tasks and keep AA batteries as a backup for uninterrupted work, especially in remote locations.
- Test Lead Storage: Always store the test leads in their designated slots on the device to keep them organized and prevent damage or loss.
9. Warranty and Support
The BSIDE U6 Digital Clamp Meter comes with a 12-month warranty from the date of purchase, covering manufacturing defects. For technical support, warranty claims, or any questions regarding the product, please contact the BSIDE International Store directly. Ensure you retain your proof of purchase for warranty validation.
Contact Information: Refer to your purchase receipt or the seller's platform for the most up-to-date contact details for BSIDE International Store.