1. Introduction

The NJTY Digital Infrared Thermometer is a non-contact device designed for accurate temperature measurement in various industrial and household applications. It provides quick and reliable readings without physical contact, making it safe and convenient for measuring surfaces in metal processing, heating, ventilation, refrigeration, and food preparation. This manual provides essential information for the safe and effective operation and maintenance of your thermometer.

NJTY Infrared Thermometer with fast response

Figure 1: NJTY Infrared Thermometer in use, highlighting its fast response.

2. Safety Information

  • Non-Human Use: This device is designed for measuring the temperature of inanimate objects only. It is NOT suitable for measuring body surface temperature, forehead temperature, or for use on babies or animals. Measuring human or animal temperature will yield incorrect results.
  • Laser Safety: The thermometer uses a laser for targeting. Avoid direct eye exposure to the laser beam. Do not stare into the beam.
  • Operating Environment: Use the thermometer within the specified ambient working temperature range (0-50°C) and relative humidity (10-90% RH non-condensing).
  • Battery Safety: Ensure correct battery polarity when installing. Do not mix old and new batteries or different types of batteries. Remove batteries if the device is not used for an extended period.
Side view of NJTY thermometer showing laser warning label

Figure 2: Laser warning label on the side of the thermometer.

3. Product Features

  • Non-contact measurement for safety and hygiene.
  • Digital display for clear and easy-to-read temperature readings.
  • High precision sensor with 0.5-second fast response time.
  • Durable construction using high-quality ABS material.
  • Laser pointer for accurate targeting of measurement area.
  • Backlight for visibility in low-light conditions.
  • Temperature unit selection (°C/°F).
  • Data Hold function.
  • Adjustable emissivity (models T400A, T600A) for improved accuracy on various surfaces.
Close-up of thermometer features: high quality sensor, ABS material, and battery bay

Figure 3: Key components: sensor, ABS material, and battery bay.

4. Specifications

FeatureSpecification
Measuring Range (T400/T400A)-50°C to 400°C (-58°F to 752°F)
Measuring Range (T600/T600A)-50°C to 600°C (-58°F to 1112°F)
Measurement Accuracy (≥ 0°C)± 1.5°C
Measurement Accuracy (< 0°C)± 3°C
Emissivity (T400/T600)0.95 (Not adjustable)
Emissivity (T400A/T600A)0.95 preset, adjustable range 0.10-1.00
Response Time0.5 seconds (95% response)
Response Wavelength8-14µm
Object Distance Ratio12:1
Ambient Working Temperature0-50°C
Relative Humidity10-90% RH non-condensing
Power Supply2 x 1.5V AAA Batteries
Display TypeDigital
StyleHandheld
Specifications for NJTY T600A model

Figure 4: Detailed specifications for the T600A model.

Specifications for NJTY T400A model

Figure 5: Detailed specifications for the T400A model.

5. Setup

5.1 Battery Installation

  1. Locate the battery bay cover, typically at the bottom of the handle.
  2. Open the battery bay cover.
  3. Insert two (2) 1.5V AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
  4. Close the battery bay cover securely.

The device requires 2x AAA batteries for operation. Batteries are typically not included with the product.

Battery bay location on the thermometer

Figure 6: Location of the battery bay.

6. Operating Instructions

6.1 Taking a Measurement

  1. Point the thermometer at the target surface. Ensure the target is within the device's object distance ratio (12:1).
  2. Press and hold the trigger to activate the laser pointer and begin measurement. The temperature reading will appear on the digital display.
  3. Release the trigger to hold the current temperature reading on the display (HOLD function).

6.2 Switching Temperature Units (°C/°F)

Press the dedicated °C/°F button on the device to toggle between Celsius and Fahrenheit temperature units.

6.3 Backlight Control

Press the backlight button (often indicated by a light bulb icon) to turn the display backlight on or off for better visibility in different lighting conditions.

6.4 Emissivity Adjustment (T400A, T600A models only)

For models T400A and T600A, the emissivity can be adjusted to improve measurement accuracy for different materials.

  • Access the emissivity adjustment mode (refer to device buttons, usually an "EMIS" or similar button).
  • Use the up/down arrows or dedicated buttons to set the emissivity value between 0.10 and 1.00.
  • Consult a reference table for common material emissivity values to ensure accurate readings.
Diagram showing adjustable emissivity range from 0.10 to 1.00

Figure 7: Adjustable emissivity range.

7. Maintenance

  • Cleaning: Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the lens is clean and free of dust or debris for accurate readings.
  • Storage: Store the thermometer in a cool, dry place away from direct sunlight and extreme temperatures. If storing for an extended period, remove the batteries to prevent leakage.
  • Battery Replacement: Replace batteries when the low battery indicator appears on the display. Follow the battery installation steps in Section 5.1.

8. Troubleshooting

ProblemPossible CauseSolution
Device does not turn onDead or incorrectly installed batteriesReplace batteries, ensuring correct polarity.
Inaccurate readings
  • Dirty lens
  • Incorrect emissivity setting (A models)
  • Target too far or too small
  • Measurement of human/animal
  • Clean the lens.
  • Adjust emissivity for the target material.
  • Move closer to the target; ensure target fills the measurement spot.
  • Confirm the device is not used for biological temperature.
Laser not visibleLaser function disabled or malfunctionCheck if there's a dedicated laser button to activate it. If not, contact support.

9. User Tips

  • Emissivity Matters: For models with adjustable emissivity (T400A, T600A), setting the correct emissivity for the material you are measuring is crucial for accuracy. Different surfaces (e.g., shiny metal vs. painted wood) have different emissivities.
  • Distance to Spot Ratio: Remember the 12:1 object distance ratio. This means that at 12 inches from the target, the measurement spot diameter is 1 inch. For accurate readings, ensure the target area is larger than the measurement spot.
  • Surface Condition: Be aware that shiny or polished surfaces can reflect ambient temperatures, potentially leading to inaccurate readings. For such surfaces, consider applying a matte black paint or tape to the measurement area if feasible.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Related Documents - T400 T400A T600 T600A

Preview NJTY T-600A Infrared Thermometer Instruction Manual
Instruction manual for the NJTY T-600A Infrared Thermometer. Learn about its features, safe operation, distance-to-spot ratio, emissivity settings, maintenance, and technical specifications for accurate non-contact temperature measurement.
Preview NJTY S18D Digital Multimeter User Manual
User manual for the NJTY S18D Digital Multimeter, detailing safety instructions, panel indications, operational guidelines, and technical specifications for accurate electrical measurements. Features include IEC-61010 compliance, backlit LCD, True RMS, and auto-ranging.
Preview NJTY Pointer Multimeter User's Guide: Features, Specifications, and Instructions
Comprehensive user guide for the NJTY Pointer Multimeter, detailing its appearance, specifications, measurement functions (DC/AC voltage, current, resistance, capacitance, etc.), and important safety reminders.
Preview NJTY 88 Series Analog Multimeter: User Manual & Technical Guide
Comprehensive user manual for the NJTY 88 series analog multimeters, covering features, specifications, safety precautions, and measurement instructions for DC/AC voltage and current, resistance, capacitance, frequency, and more.
Preview NJTY T21L LCR Meter: Auto-ranging Digital Multimeter with TRUE RMS - User Manual
User manual for the NJTY T21L LCR Meter, an auto-ranging digital multimeter with TRUE RMS. Covers features, safety, technical specifications, and operation for accurate electrical measurements.
Preview NJTY T21L LCR Meter: Auto-ranging Digital Multimeter with TRUE RMS - User Manual
Comprehensive user manual for the NJTY T21L LCR Meter, an auto-ranging digital multimeter with TRUE RMS. Covers specifications, safety, operation, and measurement functions for voltage, current, resistance, capacitance, inductance, frequency, and temperature.