1. Introduction
The JDY-16 Bluetooth-compatible 4.2 Transparent Transmission Module is a versatile wireless communication solution designed for various applications. It supports Bluetooth Low Energy (BLE) 4.2 for high-speed transparent data transmission, offering robust features such as IO control, Real-Time Clock (RTC), and Pulse Width Modulation (PWM) functions. This module facilitates seamless communication with WeChat, APP, and other devices, making it suitable for embedded systems and IoT projects.
Key features include:
- BLE high-speed transparent transmission supporting 8K Bytes/second communication rate.
- Unlimited byte transmission and reception, supporting 115200 baud rate for continuous data flow.
- Three distinct modes of operation.
- Support for serial port, IO, and APP-controlled sleep wake-up.
- Compatibility with WeChat Airsync, WeChat applets, and general APP communication.
- 4-channel IO port control.
- High-precision RTC clock.
- PWM function controllable via UART, IIC, or APP.
- Dual communication modes: UART and IIC, with UART as the default.
2. Setup
2.1 Pin Definition
The JDY-16 module features several pins for power, communication, and control. Understanding their functions is crucial for proper integration.

| Pin No. | Pin Name | Description |
|---|---|---|
| 1 | VCC | Power Supply (1.8V - 3.3V) |
| 2 | PWM1 | Pulse Width Modulation Output 1 |
| 3 | PWM2 | Pulse Width Modulation Output 2 |
| 4 | GPIO4 | General Purpose Input/Output 4 |
| 5 | NULL | No Connection |
| 6 | STAT | Status Indicator |
| 7 | NULL | No Connection |
| 8 | NULL | No Connection |
| 9 | GPIO1 | General Purpose Input/Output 1 |
| 10 | GPIO2 | General Purpose Input/Output 2 |
| 11 | NULL | No Connection |
| 12 | NULL | No Connection |
| 13 | GPIO3 | General Purpose Input/Output 3 |
| 14 | PWM3 | Pulse Width Modulation Output 3 |
| 15 | PWM4 | Pulse Width Modulation Output 4 |
| 16 | NULL | No Connection |
| 17 | ALED | Broadcast LED Indicator |
| 18 | RTCA | Real-Time Clock Alarm |
| 19 | TXD_DD | UART Transmit Data |
| 20 | RXD_DC | UART Receive Data |
| 21 | SELECT | Communication Mode Select (UART/IIC) |
| 22 | PWRC | Power Control / Wake-up Pin |
| 23 | RESET | Reset Pin |
| 24 | GND | Ground |
2.2 Factory Default Parameter Configuration
The module comes pre-configured with the following settings:
- Communication method: UART (SELECT pin is left floating)
- Serial port baud rate: 9600 (AT+BAUD4)
- Sleep mode: Power on sleep, connection wake up (AT+STARTEN1)
- Broadcast name: JDY-16 (AT+NAMEJDY-16)
- Broadcast interval: 200MS (AT+ADVIN2)
- Master-slave mode: Pass-through transmission (AT+HOSTEN0)
- Output status: Connected or disconnected status is output from the serial port (AT+ENLOG1)
- Broadcast LED indicator: Pin on (AT+ALED1)
3. Operating Instructions
3.1 Communication Modes
The JDY-16 module supports both UART and IIC communication interfaces. By default, it operates in UART mode. Ensure the SELECT pin is configured correctly for your desired communication method.
3.2 Sleep Modes
The module offers three sleep modes to manage power consumption and wake-up behavior:

| Sleep mode | Instructions | Function description |
|---|---|---|
| Sleep mode 0 | AT+STARTEN0 | Wake up, users need sleep can be controlled by AT+SLEEP command, wake up can be controlled by PWRC pin wake-up. |
| Sleep mode 1 | AT+STARTEN1 | Boot sleep, wake up after the connection, disconnect automatically into sleep. Note: AT+SLEEP invalid mode 1, sleep controls sleep by Bluetooth module itself. |
| Sleep mode 2 | AT+STARTEN2 | Boot sleep, connect and disconnect all sleep, APP to send data to the serial port module or module to send data automatic wake-up, after data transmission is completed, it will be automatic sleep. Note: AT+SLEEP invalid mode 1, sleep controls sleep by Bluetooth module itself. |
3.3 AT Commands
The module is configured and controlled using AT commands sent via the serial port. Refer to the factory default configuration for examples of AT commands. For detailed command sets, consult the comprehensive JDY-16 AT command documentation (not provided in this manual).
4. Maintenance
The JDY-16 module is designed for reliable operation within its specified parameters. To ensure longevity and optimal performance:
- Operating Environment: Maintain the working temperature between -40°C and +80°C.
- Physical Protection: Protect the module from physical damage, excessive moisture, and corrosive environments.
- Power Supply: Ensure a stable power supply within the 1.8V-3.3V range.
- Cleaning: If necessary, gently clean the module with a dry, soft cloth. Avoid using liquids or harsh chemicals.
5. Troubleshooting
This section addresses common questions and issues encountered during the use of the JDY-16 module.

| Questions | Question answer |
|---|---|
| 1: How does MCU disconnect Bluetooth connection under connection state? | In the connection state, the PWRC pin is pulled down, and the serial port sends AT+DISC to disconnect the connection. IIC can disconnect the memory address: 0X15 writes 0X01 values to indicate disconnection. |
| 2: Can it write data to the module if the connection password is incorrect? | No, it can't. Only the correct password can write data to the module. |
| 3: How much data can the serial port write at one time? | No byte limit, 100K can be sent once (master-slave communication). |
| 4: How fast can the fastest communication rate be reached? | With mobile phone measured 8K Bytes per second, module master slave communication can achieve 115200 baud rate continuous transceiver, and the rate of 115200bps. |
| 5: After configuring parameters by serial port or IIC, does it need to be restarted to take effect? | It is recommended to restart when the module parameters are set. |
| 6: Parameters of serial port or IIC configuration, is the power up stored next time? | After saving, configuring, the next power up is the last configuration parameter. |
| 7: How to test the deep sleep current of test module? | It is recommended to connect the VCC and GND pins to test current. |
6. Specifications
6.1 Technical Parameters
- Serial port transmission: No byte limit during transparent transmission.
- Effective communication distance: Within 80 meters.
- Working temperature: -40°C to +80°C.
- Communication rate: 8K Bytes per second.
- Communication modes: Supports UART and IIC.
- Working voltage: 1.8V - 3.3V.
6.2 Physical Dimensions


6.3 Working Current
The current consumption varies based on the module's working and sleep states.

| Working mode | Broadcast state | Current | Remarks |
|---|---|---|---|
| Wake up | Broadcast | 4mA | Generally communicate with APP connection, which is suggested that broadcast should not set too long, for which will affect the connection time. The broadcast interval is generally recommended to be set between 100 to 500mS. If you need to connect fast and with no power requirement, the broadcast intervals can be set to the shortest. |
| Deep no broadcast sleep | No broadcast | 1.38uA | |
| Light sleep broadcast | 100mS broadcast interval | 280uA | The following currents are much lower. |
| 200mS broadcast interval | 140uA | ||
| 300mS broadcast interval | 80uA | ||
| 400mS broadcast interval | |||
| 500mS broadcast interval | |||
| 700mS broadcast interval | |||
| 800mS broadcast interval | |||
| 900mS broadcast interval | |||
| 1000mS broadcast interval | |||
| Wake up state | Connected | 4mA | In connection state, the PWRC pin can be pulled down to send the AT command or directly set the operation mode, you can check the AT+STARTEN instruction. |
| Sleep state | Connected | 50uA |
7. User Tips
- Parameter Configuration: Always restart the module after configuring parameters via serial port or IIC to ensure the new settings take effect. Saved configurations will persist after power cycling.
- Broadcast Interval: When using broadcast mode, consider the trade-off between connection speed and power consumption. Shorter intervals allow faster connections but consume more power. For general APP communication, 100-500ms is recommended.
- Data Security: Be aware that data cannot be written to the module if an incorrect connection password is used. Ensure the correct password is provided for secure data transfer.
- Current Measurement: For accurate deep sleep current testing, connect the VCC and GND pins directly to your measurement device.
8. Warranty and Support
This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For technical support, detailed AT command documentation, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase records for reference.