1. Product Overview
The JIKONG intelligent active balanced power management system (BMS) is designed for large-capacity series lithium battery packs. It supports 8S-24S series batteries, compatible with Li-ion, LiFePo4, and LTO battery types. This BMS features voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection, a coulomb meter, Bluetooth communication, and optional GPS remote functionality.
The protection board utilizes energy transfer active balancing technology with independent intellectual property rights, capable of achieving a maximum continuous 1A/2A balance current. This high-current active equalization technology ensures battery consistency, improves battery range, and extends battery life by delaying aging.
A mobile APP is available for Android, iOS, and HarmonyOS, allowing users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth. The compact design, ease of operation, and comprehensive functions make it suitable for various applications including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.

1.1. Functional Characteristics
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support alarm function (Optional)
- Support parallel function (Optional)
- Support heating function (Optional)
- Support GPS communication
- Support ACC detection function (Optional)
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
1.2. Structural Block Diagram

2. Specifications
2.1. Product Parameters (150A Protection Board)
| Technical Index | Parameter | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <800 | mW |
| Operating Temperature | -30-70 | °C |
| Max. Number of Collection Strings | 24 | Strings |
| Max. Balancing Current | 1A or 2A | A |
| Max. Charging Current | 150 | A |
| Max. Discharge Current | 150 | A |
| Max. Instantaneous Current | 300 | A |
| Max. Internal Loop Resistance | 0.365 | mΩ |
| Protection Board Size | 162*102*20.4 | mm |
| Finished Weight | 560 | g |
2.2. Product Parameters (200A Protection Board)
| Technical Index | Parameter | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <800 | mW |
| Operating Temperature | -30-70 | °C |
| Max. Number of Collection Strings | 24 | Strings |
| Max. Balancing Current | 2 | A |
| Max. Charging Current | 200 | A |
| Max. Discharge Current | 200 | A |
| Max. Instantaneous Current | 400 | A |
| Max. Internal Loop Resistance | 0.275 | mΩ |
| Protection Board Size | 162*102*20.4 | mm |
| Finished Weight | 560 | g |
2.3. Product Dimensions



3. Installation & Wiring
3.1. General Installation Steps
- Connect all the balance cables to the BMS.
- Insert the main power cable (B-line) into the BMS.
- Connect the B-line and the P-line to the battery pack.
The JK-BxAxxS-15P/20P series protection board is suitable for 7-24 series lithium battery packs. Different cell numbers require different wiring methods as shown in the following diagrams.
3.2. Wiring Diagrams



3.3. Packing List

3.4. Interface Definition

For detailed pin definitions of connectors P1 (XH-15AW for Balance with Acquisition interface), P2 (XH-11AW for Balance with Acquisition interface), P3 (XH-4AW for Temperature interface), P4 (A1254WF-4A for Communication interface), P5 (1.25T-4PWT for GPS interface), P6 (A1254WF-6A for Display interface), P7 (A1254WF-3A for Parallel interface), P8 (A1254WF-2A for Alarm interface), and P9 (A1254WF-5A for ACC interface), please refer to the comprehensive PDF user manual, section 5.2 Product Connector, LED Definition, pages 24-26.
4. Operation
4.1. APP Installation
The mobile APP matching the product can be obtained by scanning the QR code shown below. An Android Version 7 minimum is required for the Android APP.

4.2. Device Activation
Before powering on the protection board, ensure that the balance cables are properly connected and that the P- and B- lines are correctly wired. Verify that the protection board is securely fixed to the battery cells. Incorrect connections can lead to abnormal operation or damage.
The protection board does not have a power-on control switch. It is designed for charging activation mode, meaning the charger voltage must be 2V higher than the battery voltage to activate the BMS after battery assembly. Alternatively, the BMS can be activated via a button or a display screen. Users with an optional display screen and button can simply insert the cable into the display interface and press the button to activate.
4.3. Active Balancing
Active balancing is achieved by transferring energy from higher-voltage cells to lower-voltage cells, minimizing energy loss and achieving voltage balance. Users must set basic battery parameters in the APP, including cell count, battery capacity, and trigger equalization differential pressure (default value can be retained). The default balance current is 1A/2A, adjustable based on battery capacity (recommended not to exceed 0.2C of battery capacity). If not needed, the balancing function can be turned off in the APP's BMS control page.

4.4. Heating Function (Optional)
The BMS supports an optional heating function for low-temperature conditions, using a resistance heater or heating film to prevent charging/discharging failures due to reduced battery activity. The designed heating current is 10A. Users can switch this function on/off via the APP. It is recommended to install a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary protection to prevent thermal runaway.
4.5. Alarm Function (Optional)
The BMS supports an optional alarm function to alert users to security risks such as over-temperature, overcharge, or over-discharge conditions.
4.6. Battery Parallel Function (Optional)
For energy storage battery packs, the BMS supports an optional parallel function. This feature requires synchronous use with parallel modules and disabling the "disable charging current limiting" function in the APP.
4.7. ACC Detection Function (Optional)
The BMS supports an optional ACC detection function to enable discharge. This can be achieved by applying a voltage between ACC+ and ACC- (20V-100V range) or by directly short-circuiting ACC+ and ACC-. A charger detection function (C_detect+ and C_detect- interfaces) is also available for enabling charging.
4.8. Communication Functions (Optional)
The BMS supports optional CAN and RS485 communication. Users can select CAN or RS485 for multiplexed ports on the APP's BMS control page. For specific communication protocols and address settings, refer to the JIKONG Protection Board communication protocol document.
4.9. Display Options








5. Protection Functions
The JIKONG Smart BMS provides comprehensive protection features to ensure the safety and longevity of your battery pack.
5.1. Charge Overvoltage Protection and Recovery
The BMS is equipped with standard charge overvoltage protection. Users can set the single overcharge protection voltage and recovery voltage in the APP. If any cell exceeds the set overvoltage, the BMS will stop charging. Charging resumes when all cell voltages drop below the recovery voltage, preventing overcharging and cell damage.
5.2. Discharge Undervoltage Protection and Recovery
Standard discharge undervoltage protection is included. Users can set the battery undervoltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell drops below the protection voltage during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell drops below the automatic shutdown voltage, the BMS will shut down to protect the battery.
5.3. Charge Overcurrent Protection and Recovery
Standard charge overcurrent protection is provided. Users can set the continuous charging current, overcurrent delay, and recovery time in the APP. If the charging current exceeds the set limit for the specified delay, the BMS will stop charging. Charging resumes after the recovery time has elapsed.
5.4. Discharge Overcurrent Protection and Recovery
Standard discharge overcurrent protection is included. Users can set the continuous discharge current, overcurrent delay, and recovery time in the APP. If the discharge current exceeds the set limit for the specified delay, the BMS will stop discharging. Discharge resumes after the recovery time has elapsed. (Note: The maximum continuous discharge current should not exceed the nominal current of 150A/200A).
5.5. Overtemperature Protection and Recovery
The BMS features standard charge and discharge overtemperature protection. Users can set the overtemperature protection and recovery values for both charging and discharging in the APP. If the temperature exceeds the set limit, the BMS will stop the respective operation (charging or discharging). The operation resumes when the temperature falls below the recovery value.
5.6. Low Temperature Protection and Recovery
Standard charge low-temperature protection is included. Users can set the low-temperature protection and recovery values for charging in the APP. If the temperature drops below the set limit, the BMS will stop charging. Charging resumes when the temperature rises above the recovery value. For extremely cold environments, the optional heating function is recommended.
5.7. Short Circuit Protection and Recovery
The BMS is equipped with standard short circuit protection. Users can set the short circuit protection delay (in microseconds) and recovery time (in seconds) in the APP. If a short circuit is detected, the BMS will activate protection and then recover after the set time. This feature helps prevent damage from sudden high currents during charger connection or load connection.
5.8. Emergency Switch
The BMS includes a standard emergency switch function. If issues like over-temperature, over-discharge, overcharge, or cell string drops occur, activating the emergency switch in the APP's BMS control page will enable charge and discharge for 30 minutes, providing an emergency use period. The BMS will continue to operate until the 30-minute cycle ends, even if a single cell reaches the automatic shutdown voltage.
5.9. Intelligent Sleep
The BMS features a standard intelligent sleep function, which can be enabled or disabled in the APP. This function puts the BMS into a low-power sleep state (when charge/discharge current is less than 1A for 26 consecutive hours) to reduce self-consumption. The BMS can be reactivated by pressing a button or connecting a charger.
6. Parameter Settings
The JIKONG Smart BMS allows for extensive parameter customization via the mobile APP. Users can adjust various protection values such as overcharge, over-discharge, overcurrent, temperature, and balance settings.
6.1. Default Parameters
The following table outlines the default parameters for different battery types (Li-ion, LiFePo4, LTO). These values can be adjusted as needed through the APP.
| Parameter | Li-ion Default | LiFePo4 Default | LTO Default | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Max. Balancing Current | 1A or 2A | 1A or 2A | 1A or 2A | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 5 | 5 | 5 | µS |
| Short Circuit Protection Release Time | 30 | 30 | 30 | S |
| Charging Overtemperature Protection | 70 | 70 | 70 | °C |
| Charge Overtemperature Recovery | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection | -20 | -20 | -20 | °C |
| Charge Low Temperature Recovery | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
For a complete list of configurable parameters and their detailed descriptions, please refer to the "Instructions for Setting Protection Board Parameters" section (6.3) in the full PDF user manual.
7. User Tips
- **Language Support:** While the product is generally easy to install and use, the provided instructions might not be available in all languages. If you encounter language barriers, consider using translation tools for the PDF manual or contacting customer support for assistance.
- **Battery Configuration:** When selecting a BMS, ensure it matches your battery's specific configuration (e.g., 16 elements, 280Ah LiFePo4, 3.2V for 48V system). Refer to the "Product Selection Guide" (Section 2) and "Product Adaptation Guide" (PDF pages 8-9) to choose the correct model for your application, especially for solar panels and inverters.
- **Wiring Verification:** Always double-check all wiring connections, especially balance cables and main power lines (B- and P-), before activating the BMS to prevent damage or abnormal operation.
- **APP Features:** Utilize the mobile APP to its full potential for monitoring battery status, adjusting parameters, and controlling various functions.
8. Troubleshooting
If you experience any issues with your JIKONG Smart BMS, consider the following general troubleshooting steps:
- **Check Connections:** Ensure all wiring, including balance cables, main power cables, and communication interfaces (if used), are securely connected and correctly oriented.
- **Verify Parameters:** Review the parameter settings in the mobile APP. Incorrect voltage limits, current limits, or temperature thresholds can lead to unexpected behavior or protection activation. Refer to the "Parameter Settings" section (Section 6) and the full PDF manual for default and recommended values.
- **BMS Activation:** If the BMS does not power on, ensure it has been properly activated, either by connecting a charger (if in charging activation mode) or by pressing the physical switch/display button (if applicable).
- **Consult PDF Manual:** The comprehensive PDF user manual contains detailed information on functional characteristics, error codes (if any are displayed), and specific troubleshooting scenarios.
- **Contact Support:** If the problem persists after performing basic checks, contact JIKONG customer support for further assistance.
9. Warranty & Support
For detailed information regarding product warranty, service, and technical support, please refer to the official JIKONG documentation or contact the seller directly. The full user manual in PDF format is available for download by scanning the QR code in the APP installation section or can be referenced contextually via the provided PDF link: JIKONG Lithium Battery Active Balance Protection Board Manual (PDF).
JIKONG is committed to providing high-quality products and support. For any inquiries or assistance, please reach out to the JIKONG BMS Flagship Store or authorized distributors.