VEVOR EF-14-ECG

Rate this product if you’ve used it
Contents

VEVOR 14'' Exhaust Fan with Temperature Humidity Controller User Manual

Model: EF-14-ECG

Brand: VEVOR

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your VEVOR 14'' Exhaust Fan with Temperature Humidity Controller. This high-airflow exhaust fan is designed to effectively manage environmental conditions by eliminating excess heat, humidity, unpleasant odors, and dust from various enclosed spaces. Its intelligent control system allows for precise regulation of airflow based on temperature and humidity levels, ensuring optimal ventilation and air quality.

2. Important Safety Instructions

Please read and understand all safety instructions before installing or operating the fan. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always disconnect power before servicing or cleaning the unit.
  • Ensure the fan is installed in a location with adequate structural support.
  • Do not operate the fan with a damaged cord or plug.
  • Keep hands and foreign objects away from the fan blades during operation.
  • This fan is designed for ventilation purposes only. Do not use it for exhausting hazardous or explosive materials.
  • Ensure proper grounding to prevent electrical shock.
  • Keep children and pets away from the operating fan.

3. Package Contents

Verify that all items are present and in good condition upon unpacking:

  • 1 x VEVOR 14'' Exhaust Fan Unit
  • 1 x Temperature Humidity Controller
  • 1 x Power Cord (5.6 ft)
  • 4 x Mounting Bolts
  • 1 x User Manual (this document)

4. Specifications

Diagram showing dimensions and specifications of the VEVOR 14 inch exhaust fan, including overall size, shutter opening, depth, weight, RPM, CFM, color, and material.

Figure 1: Fan Dimensions and Key Specifications

FeatureSpecification
Model NumberEF-14-ECG
Fan Dimensions (Overall)17.1" x 17.1" (43.4 cm x 43.4 cm)
Shutter Opening Dimensions14.1" x 14.1" (35.8 cm x 35.8 cm)
Depth3.9" (9.9 cm)
Power Supply120V/60Hz
Power Consumption30W
Air Volume1024 CFM
Rotating Speed1600 rpm
Motor TypeSealed EC Motor (with Thermal Overload Protection, Permanently Lubricated, ETL Listed)
MaterialPowder-coated Steel (frame), Aluminum Alloy (fan blades & shutter)
Weight8.95 lbs (4.06 kg)
ColorBlack
Power Cord Length5.6 ft

5. Setup and Installation

The VEVOR exhaust fan is designed for "Plug and Play" installation with minimal assembly required. It comes fully assembled, ready for mounting.

5.1 Mounting the Fan

  1. Choose Location: Select a suitable wall or opening in your greenhouse, garage, workshop, shed, or attic. Ensure the location has adequate structural support for the fan's weight and operation.
  2. Prepare Opening: If installing in a new opening, ensure it is appropriately sized for the fan (refer to specifications for shutter opening dimensions).
  3. Secure the Fan: Position the fan unit in the desired opening. Use the provided 4 mounting bolts to securely fasten the fan to the wall or frame. Tighten the bolts with a wrench.
VEVOR 14 inch exhaust fan with controller, showing the fan unit and separate controller.

Figure 2: Exhaust Fan Unit and Controller

Image showing the fan installed on a wall, with the power cord and controller sensor. Also shows application examples in a greenhouse and a garage.

Figure 3: Plug and Play Installation Overview

5.2 Installing the Controller

  1. Mount the Controller: Choose a convenient location for the temperature and humidity controller. Secure it to a wall using appropriate fasteners (not explicitly mentioned if included, but implied by installation steps).
  2. Connect Cables:
    • Connect the fan's cable to the appropriate output port (e.g., OUT1 or OUT2) on the controller.
    • Connect the sensor cable to the "SENSOR" port on the controller.
  3. Power Connection: Plug the 5.6 ft power cord from the fan unit into a standard 120V/60Hz electrical outlet.
Close-up of the smart programming controller showing buttons for Mode Setting, Up, Down, and ECO Mode, along with display for temperature, humidity, and fan speed.

Figure 4: Intelligent Controller Interface

For a visual guide on installation, please refer to the video below:

Play video
Watch video online

Video 1: VEVOR Exhaust Fan Installation and Operation Demo

6. Operation

The intelligent controller allows for precise control over your fan's operation based on environmental conditions.

6.1 Controller Overview

The controller features a digital display showing current temperature and humidity, along with settings. Buttons are provided for Mode Setting, Up, Down, and ECO Mode.

  • Mode Setting: Cycle through various operational modes (e.g., Auto Mode, Timer Mode, Alarm Mode, ON/OFF).
  • Up/Down Buttons: Adjust set points for temperature, humidity, or fan speed within selected modes.
  • ECO Mode: Activates an energy-saving mode.

6.2 Operating Modes

  • Auto Mode: The fan automatically adjusts its 10-speed settings in response to pre-set temperature and humidity triggers. This mode is ideal for maintaining consistent environmental conditions without constant manual intervention.
  • Timer Mode: Set the fan to operate for specific durations.
  • Alarm Mode: Configure alarms to alert you when temperature or humidity levels exceed or fall below desired thresholds.
  • ON/OFF: Manually turn the fan on or off.

Refer to the controller's display and buttons (Figure 4) to navigate and adjust settings according to your specific ventilation needs.

Image showing the automatic gravity shutter in both closed and open positions, highlighting its rust-proof, corrosion-proof, and non-deformed features.

Figure 5: Automatic Gravity Shutter

7. Maintenance

Regular maintenance ensures the longevity and efficient operation of your VEVOR exhaust fan.

  • Cleaning: Periodically clean the fan blades and shutter to prevent dust and debris buildup, which can reduce airflow and efficiency. Ensure power is disconnected before cleaning. Use a soft cloth and mild detergent if necessary.
  • Motor: The sealed EC motor is permanently lubricated and requires no additional lubrication.
  • Inspection: Regularly inspect the power cord, controller connections, and mounting bolts for any signs of wear, damage, or looseness. Tighten bolts as needed.
Image detailing the Sealed EC Motor features: Thermal Overload Protection, Permanently Lubricated, ETL Listed, and 1024 CFM airflow.

Figure 6: Sealed EC Motor Features

8. Troubleshooting

If you encounter issues with your fan, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Fan does not turn onNo power, loose connection, controller settingCheck power outlet, ensure all cables are securely connected, verify controller is not in OFF mode or set to a trigger not yet met.
Low airflowBlocked fan blades/shutter, incorrect speed settingClean fan blades and shutter, increase fan speed via controller.
Unusual noise during operationLoose mounting, debris in fan, damaged motor/bladesCheck mounting bolts for tightness, inspect for and remove any debris, contact support if motor/blades appear damaged.
Controller display is blankNo power to controller, faulty controllerEnsure fan unit is powered, check controller cable connection. If problem persists, contact support.

9. User Tips

  • Optimal Placement: For best results, position the fan to create a cross-ventilation effect, drawing stale air out and allowing fresh air in from an opposite opening.
  • Controller Customization: Experiment with different temperature and humidity set points in Auto Mode to find the ideal balance for your specific environment (e.g., greenhouse, garage).
  • Energy Saving: Utilize the ECO Mode for reduced power consumption when full ventilation is not required.
  • Regular Cleaning: Keep the automatic gravity shutter clean to ensure it opens and closes smoothly, preventing debris from entering the fan.

10. Warranty and Support

VEVOR products are built to last and come with a commitment to quality. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official VEVOR website. Please have your model number (EF-14-ECG) and purchase details ready when contacting support.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?