Daxtromn AGH-6.2KW-PRO

Contents

Daxtromn 6.2KW Hybrid Solar Inverter User Manual

Model: AGH-6.2KW-PRO

Brand: Daxtromn

1. Introduction

This manual provides essential information for the safe and efficient operation of your Daxtromn 6.2KW Hybrid Solar Inverter. This multi-function inverter/charger integrates inverter, solar charger, and battery charger functionalities to provide reliable, uninterruptible power. It features a comprehensive LCD display for user-configurable settings and easy operation.

Key features include:

  • Pure Sine Wave Output
  • Max 120A MPPT Solar Charger
  • Max 500VDC PV Input
  • Dual AC Output for critical and non-critical loads
  • Wide PV input voltage range (120~450VDC)
  • Output power factor 1.0
  • Compatible with 24V/48V battery systems
  • Optional WiFi Module for remote monitoring
  • Operates efficiently with or without a battery
  • Supports 50Hz or 60Hz (program adjustable)
  • Can use AC grid or generator power
  • Built-in anti-dusk kit for harsh environments
  • Optional DC output for low-power DC devices

For a visual overview of the product, please watch the video below:

Play video
Watch video online

Video: Daxtromn AGH Series Hybrid Solar Inverter Overview

2. Safety Warnings

WARNING: All wiring must be performed by a qualified personnel.

CAUTION: Shock Hazard. Installation must be performed with care due to high battery voltage in series.

DO NOT CONNECT THE SECOND OUTPUT TO THE GRID. Doing so will damage your inverter.

  • This inverter is designed for use with solar panels and batteries. Ensure all components are correctly rated and installed.
  • Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) is connected to negative (-).
  • The battery cannot be connected while the inverter is running. Always power off the inverter before connecting or disconnecting batteries.
  • When connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
  • For AC input power, install a separate AC breaker between the inverter and the AC input power source.
  • The inverter is a high-frequency inverter. When connecting inductive loads (e.g., motors, refrigerators, air conditioners), consider that their starting power can be 3 times or more than their rated power. Ensure the inverter's capacity is sufficient for the instantaneous current.
  • Install the unit by screwing two M6 screws into a concrete or other non-combustible surface only.

3. Product Overview

The Daxtromn AGH-6.2KW-PRO Hybrid Solar Inverter is a compact and robust unit designed for efficient energy management. Below is a diagram identifying its main components and connections.

Product Overview Diagram with labeled components

Figure 3.1: Product Overview with Labeled Components

Component Identification:

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Power on / off switch
  7. AC input
  8. Main output
  9. Second output
  10. Battery input
  11. PV input
  12. RS-232 communication port/WiFi-port
  13. Circuit breaker
  14. BMS/RS485 port

The rear panel provides all necessary connection terminals:

Rear view of the inverter showing AC, DC, and communication ports

Figure 3.2: Inverter Rear Panel Connections

4. Specifications

The Daxtromn AGH-6.2KW-PRO inverter offers robust performance for various solar applications. Below are the detailed technical specifications:

Detailed technical specifications table for the inverter

Figure 4.1: Detailed Technical Specifications

General Specifications:

AttributeValue
Brand Namepyrosolar
Model NumberAGH-6.2KW-BMS
Output Current6.2KW-120A/4.2KW-140A
Output Power1 - 200KW
Size424*335*110mm
Output TypeDUAL
Weight10kg
Output Frequency50Hz/60Hz(Auto sensing)
Is Smart DeviceYes
OriginMainland China
CertificationCE
Phase1-Phase
Rated Output Power6200W/6200VA
Maximum PV Array Power6500W
MPPT Voltage Range90~450VDC
Nominal Output Voltage220/230/240VAC
Number of MPPT/Max Input Current1/23A
Output Voltage Range195.5~253VAC
Battery voltage48V
Maximum AC Charging Current100A
Number of Load output2
Communication InterfaceRS232/WIFI/RS485
Output Voltage WaveformPure sine Wave
Solar inverter TypeON/OFF Grid Hybrid inverter
Operating Temperature- 10 ~50℃
With BMSYes
Work without batteryYes
Warranty1 Year

Dimensions and Weight:

Inverter dimensions: 423 x 334 x 110 mm and Net Weight: 10.0 kg

Figure 4.2: Inverter Dimensions and Weight

  • Net Weight: 10.0 kg / 22.0 lb
  • Dimension (D*W*H): 423 x 334 x 110 mm / 16.7 x 13.2 x 4.3 in

5. Installation and Setup

5.1 General Connection Diagram

The inverter can be connected to solar power, an external battery, and either a generator or utility grid, providing power to home appliances.

General connection diagram showing solar, battery, grid/generator, and home appliance connections

Figure 5.1: General Connection Diagram

Detailed wiring and technical specifications diagram

Figure 5.2: Detailed Wiring and Technical Specifications

5.2 Battery Connection

For safety and optimal performance, follow these steps for battery connection:

  1. Remove insulation sleeve 18 mm for positive and negative conductors.
  2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the chart below.
Battery connection diagram for 3.6KW and 6.2KW/7.2KW inverters

Figure 5.3: Battery Connection Diagram

CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between the battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed.

Recommended battery cable size:

Table for recommended battery cable size and torque value

Figure 5.4: Battery Cable Requirements

Insert the battery wires flatly into battery connectors of the inverter and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure polarity at both the battery and the inverter/charge is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

5.3 PV Connection

CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between the inverter and PV modules.

WARNING: It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.

PV Module Selection:

  • Open circuit Voltage (Voc) of PV modules should not exceed max. PV array open circuit voltage of inverter (500VDC).
  • Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
PV connection diagram and cable size table

Figure 5.5: PV Connection Requirements

5.4 AC Input/Output Connection

CAUTION: Before connecting to AC input power source, please install a separate AC breaker between the inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 32A for 3.6KW and 50A for 6.2KW/7.2KW.

CAUTION: There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.

WARNING: All wiring must be performed by a qualified personnel.

WARNING: It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.

Suggested cable requirement for AC wires:

Table for recommended AC wire gauge and torque value

Figure 5.6: AC Wiring Requirements

6. Operating Modes

The inverter supports various charging and discharge modes to optimize energy usage and reduce electricity bills.

Diagram showing four charging modes and three discharge modes

Figure 6.1: Charging and Discharge Modes

6.1 Output Source Priority

You can configure the load power source priority based on your energy management strategy:

Table explaining Utility first, Solar first, and SBU priority output modes

Figure 6.2: Output Source Priority Settings

  • Utility first (01 USB): Utility will provide power to the loads as first priority. Solar and battery energy will provide power to the loads only when utility power is not available.
  • Solar first (default) (01 Snb): Solar energy provides power to the loads as first priority. If solar energy is not sufficient to power all connected loads, utility will supply power to the loads at the same time. Battery provides power to the loads only when any one condition happens: Solar energy and utility is not available, or Solar energy is not sufficient and utility is not available.
  • SBU priority (01 Sbu): Solar energy provides power to the loads as first priority. If solar energy is not sufficient to power all connected loads, battery energy will supply power to the loads at the same time. Utility provides power to the loads only when battery voltage drops to either low-level warning voltage or the setting point in program 12.

6.2 Dual AC Output Function

The inverter features a dual AC output. The 'Second Out' port is designed to guarantee that important equipment continues to run even when the main AC input is unavailable and the battery voltage drops below a set threshold. In such a scenario, the main AC output will cut off automatically, and the battery or PV will only offer power to the second AC output.

7. Monitoring and Control

The inverter can be monitored and controlled via the SmartESS App, providing convenient access to system data and settings. A WiFi module is required for this functionality, which may need to be purchased separately.

SmartESS App interface for monitoring and control

Figure 7.1: SmartESS App Monitoring

The app is available on Google Play and the App Store. Ensure your WiFi module is connected and configured according to its specific instructions.

8. User Tips

  • The inverter's fans are generally quiet during operation.
  • When operating without an external battery, the solar panel voltage must be above 150VDC for the inverter to start working normally. With an external battery, 120VDC is sufficient.
  • For optimal performance and longevity, ensure all connections are secure and cables are of the recommended gauge.
  • Regularly check the LCD display for system status and any fault indicators.

9. Troubleshooting

This section addresses common questions and potential issues you might encounter.

Frequently Asked Questions:

  • Q: What is the Rated output power?
    A: It's 6200W for Model: AGH-6.2KW-PRO.
  • Q: What is the max charge current for the battery?
    A: It's 120A.
  • Q: What is the MAX DC PV Input?
    A: It's 500VDC.
  • Q: How many AC output ports?
    A: 2 loads output.
  • Q: How many volts of external battery are used?
    A: 48V for AGH-6.2KW-PRO.
  • Q: Can it support Parallel operation?
    A: No, this model does not support parallel operation.
  • Q: Does it have a WiFi Module?
    A: Yes, a WiFi module is available, typically as an optional purchase.

Common Issues:

  • Inverter not starting with solar panels (no battery): Ensure the PV input voltage is above 150VDC.
  • Inverter not starting with solar panels (with battery): Ensure the PV input voltage is above 120VDC.
  • Overload or shutdown: Check if connected inductive loads (e.g., motors) are causing high instantaneous current during startup. Ensure the total load does not exceed the inverter's capacity.
  • No output from the second AC port: Verify that the main AC input is present and battery voltage is above the set threshold. The second output is for critical loads when main power is lost and battery is low.

10. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your inverter:

  • Cleaning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating. Use a soft, dry cloth for cleaning the exterior.
  • Connection Checks: Periodically inspect all electrical connections (PV, battery, AC input/output) to ensure they are tight and free from corrosion. Loose connections can lead to poor performance or safety hazards.
  • Environmental Conditions: Ensure the inverter is operating within its specified temperature range (-10°C to 50°C) and in a dry, well-ventilated area.
  • Firmware Updates: If using the WiFi module, check for available firmware updates through the SmartESS App to ensure you have the latest features and bug fixes.

11. Warranty and Support

Warranty Information:

This product comes with a 1-Year Warranty from the date of purchase.

Additional Resources:

For a more detailed manual and further technical support, please refer to the official documentation:


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.