JIKONG BD4A8S4P

Contents

JIKONG Smart BMS BD4A8S4P User Manual

Model: BD4A8S4P | Brand: JIKONG

1. Product Overview

The JIKONG Smart BMS (Battery Management System) BD4A8S4P is an intelligent protection board designed for large-capacity series lithium battery packs. It offers comprehensive features including voltage acquisition, high-current active balancing, overcharge/over-discharge protection, overcurrent protection, over-temperature protection, coulomb meter, Bluetooth communication, and GPS remote functionality.

This BMS is compatible with various battery types, including Li-ion, LiFePo4, and LTO, and supports 4S-8S configurations with a continuous discharge current of 40A.

JIKONG Smart BMS BD4A8S4P board with key features listed

Figure 1: JIKONG Smart BMS BD4A8S4P with key specifications.

Key Features:

  • Active Equalization: Achieves a maximum continuous 0.4A balance current to ensure battery consistency and extend battery life.
  • Comprehensive Protection: Includes overcharge, over-discharge, overcurrent, short circuit, over-temperature, and low-temperature protection.
  • Smart Management: Features Bluetooth communication for real-time monitoring and parameter adjustment via a mobile APP (Android/iOS).
  • Expandable Interfaces: Supports GPS, display screens (LCD), RS485, and CAN communication (optional).
  • Heating Function: Optional heating to prevent performance degradation in low-temperature environments.
  • Battery Parallel Function: Supports parallel connection of battery packs for energy storage applications.

2. Specifications

General Specifications:

Attribute Value
Brand Name JIKONG
Type LI-ION Battery BMS
Handware or Smart SMART BMS
Balance Function Active Balanced BMS
Charge and Discharge Port Common Port BMS
Function Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection
Temperature sensor Yes
Active Balance Yes
Communication RS485/BT
Battery Strings 4S-8S
Battery Type Li-ion/LiFePo4/LTO
Active Current 0.4A
Charge/Discharge Current 40A
Adapting system Android or iOS
Balance Wires Yes and Free

Physical Dimensions:

Parameter Value Unit
Supply voltage 10-36 V
Operating power consumption <900 mW
Operating temperature -30-70 °C
Maximum number of collection strings 8 String
Maximum balancing current 0.4 A
Maximum charging current 40 A
Maximum discharge current 40 A
Maximum instantaneous current 80 A
Maximum internal loop resistance 1.5 mΩ
Protective plate size 121.5×93×17.6 mm
Finished weight 180 g
Diagram showing six security protection features: Overcharge, Short circuit, Over discharge, Overcurrent, ALL-IN, Over temp protection.

Figure 2: Six Security Protection Features of the BMS.

3. Package Contents

Upon receiving your JIKONG Smart BMS, please verify that all components are present and undamaged:

  • JIKONG Smart BMS Board
  • Operating Manual
  • Balance Wires (70cm)
  • NTC Temperature Sensor (40cm)
  • Switch (50cm)
  • Screws (x6)
  • Packaging Box
Image showing the package contents: BMS board, operating manual, screws, NTC sensor, switch, and wires.

Figure 3: Contents included in the JIKONG Smart BMS package.

4. Setup and Installation

4.1. Battery Assembly Instructions

When assembling lithium batteries, a protective board (BMS) must be installed. The connection method depends on whether batteries are in series or parallel:

  • Series Connection: The battery is connected in series, increasing the total voltage while the capacity remains unchanged.
  • Parallel Connection: Batteries are connected in parallel, keeping the voltage unchanged while increasing the total capacity.
Diagram illustrating series and parallel battery connections with a protection board.

Figure 4: 3.2V LiFePO4 Battery Assembly Instructions.

4.2. Wiring Diagram

The JIKONG Smart BMS BD4A8S-4P/6P series protection board is suitable for 3-8 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack. Always ensure correct connections to prevent damage.

Detailed wiring diagram for JIKONG Smart BMS BD4A8S-4P/6P, showing connections for load, charger, temperature probe, and balance wires.

Figure 5: JK-BD4A8S-4P/6P Wiring Diagram.

Important Wiring Steps:

  1. Connect the balance wires from the battery cells to the P1 connector on the BMS. Ensure the last power cord (B+) is connected to the main positive pole of the battery.
  2. Connect the main negative pole of the battery to the B- terminal on the BMS.
  3. Connect the load and charger negative terminals to the P- terminal on the BMS.
  4. Connect the NTC temperature sensor to the dedicated NTC interface.
  5. If using, connect the optional switch, LCD display, or RS485/CAN communication modules to their respective ports as shown in the diagram.
Diagram showing connections for NTC, RS485, Switch, and LCD display to the BMS board.

Figure 6: BMS Interface Connections for NTC, RS485, Switch, and LCD.

4.3. APP Installation and Device Activation

The JIKONG Smart BMS features a mobile APP for Android and iOS systems, allowing you to monitor battery status and adjust parameters via Bluetooth.

APP Download:

  • iOS: Search for "JIKONG BMS" in the Apple App Store.
  • Android: Search for "JK BMS" in the Google Play Store. (Android Version 7 minimum required)
QR code for downloading the JIKONG BMS mobile APP.

Figure 7: Scan to download the JIKONG BMS Mobile APP.

Device Activation:

  1. Before powering on, ensure all balance cables and main power connections (P- and B-) are correctly and securely connected.
  2. The BMS does not have a power-on switch. It is designed for charging activation. After battery assembly, connect a charger with a voltage at least 2V higher than the battery pack voltage to activate the BMS.
  3. Alternatively, if you have an optional display screen and button, insert the cable into the display interface and press the button to activate.
  4. The total voltage of the battery pack must be greater than 20V (for default BMS) or 10V (for 4S BMS) before startup.

5. Operating Instructions

5.1. Mobile APP Operation

Once the BMS is activated, turn on Bluetooth and GPS on your mobile phone. Open the JIKONG BMS APP, search for devices, and connect to your BMS. The default password is 1234.

For the first startup, you will need to set parameters. The default parameter setting password is 123456. Configure the number of units (strings) and battery type. After setting, return to the real-time status page to check battery status. Ensure no error messages are displayed and the system operates normally. In the APP, blue indicates the highest cell voltage, and red indicates the lowest.

Screenshot of the Smart BT APP interface showing real-time battery data monitoring.

Figure 8: Smart BT APP Interface for real-time data monitoring.

Image showing the self-developed APP monitoring battery data.

Figure 9: Self-developed APP for battery data monitoring.

5.2. Active Equalization

The BMS uses active equalization to transfer energy from high-voltage cells to low-voltage cells. You can set the balance trigger pressure difference (in mV) in the APP. Equalization automatically activates when the voltage difference between any two battery strings exceeds the set value and turns off when it falls below the set value. The default balance current is 0.4A. It is recommended that the balance current does not exceed 0.2C of the battery capacity.

Video 1: JIKONG Active Balance BMS demonstration, showing balanced cell voltage difference to improve battery performance, 24-hour detection, real-time automatic balancing, and smart management via Bluetooth.

5.3. Smart Energy Working Modes

The BMS supports different working modes to optimize battery usage and longevity:

  • Storage Mode: When the BMS is in storage mode (transportation, storage, offline, or wireless transmission off), it does not consume battery pack current. Charging activates this mode.
  • Normal Working Mode: When the charger is inserted in storage mode or off mode, the BMS returns to normal working mode, activating all protection, equalization, and communication functions.
  • Standby Mode: When the battery pack is in a static state (no charge/discharge current, no equilibrium current), the BMS automatically enters standby mode after a set time (1-30 days, configurable).
  • Shutdown: To prevent power waste and battery damage during long periods of disuse, the BMS automatically shuts down when a cell falls below the shutdown voltage.
Flowchart illustrating smart energy working mode switching: Storage Mode, Normal Working Mode, Standby Mode, and Shutdown.

Figure 10: Smart Energy Working Mode Switching.

5.4. Protection Functions

The BMS provides multiple protection mechanisms to ensure battery safety and performance:

  • Charge Overvoltage Protection: Prevents overcharging. Users can set overcharge protection and recovery voltages in the APP.
  • Discharge Undervoltage Protection: Prevents over-discharging. Users can set undervoltage protection, recovery, and automatic shutdown voltages.
  • Charge Overcurrent Protection: Protects against excessive charging current. Configurable continuous charging current, delay, and release times.
  • Discharge Overcurrent Protection: Protects against excessive discharging current. Configurable continuous discharge current, delay, and release times (max 40A/60A).
  • Over-temperature Protection: Protects against high temperatures during charge and discharge. Configurable over-temperature protection and recovery temperatures.
  • Low-temperature Protection: Protects against low temperatures during charging. Configurable low-temperature protection and recovery temperatures.
  • Short Circuit Protection: Automatically protects against short circuits. Configurable delay (µs) and recovery time (S).

5.5. Heating Function (Optional)

The BMS supports an optional heating function to warm the battery in low temperatures, preventing reduced activity and charging/discharging issues. The designed heating current is 4A. Users can control this function via the APP. It is recommended to install a temperature control switch (45°C to 65°C normally closed) in series with the heating circuit for secondary protection.

Heating Conditions:

  1. Battery temperature is lower than the low-temperature protection temperature for charge.
  2. Connecting a heating film will activate heating via the APP, consuming battery power.
  3. Heating via the charger depends on the protection board hardware and charger compatibility.

5.6. Other Functions

  • Alarm Function: The BMS can trigger an external alarm if security risks like over-temperature, overcharge, or over-discharge are detected.
  • Battery Parallel Function: Supports parallel connection of battery packs, requiring synchronous use with parallel modules and disabling "charging current limiting" in the APP.
  • Discharge Precharge Function: Optional function with a default precharge time of 5 seconds, configurable via the APP.
  • Emergency Switch: A standard function that, when activated via the APP, allows charge and discharge for 30 minutes during issues like over-temperature, over-discharge, or dropped strings, providing emergency use time.
  • Intelligent Sleep: An optional function to reduce BMS energy consumption when in standby (charging/discharging current less than 1A for 26 consecutive hours). Can be reactivated by button or charger.
  • Communication Functions (CAN/RS485): Supports optional CAN/RS485 communication. Users can configure the address and protocol via the APP. Refer to the Jikong Protection Board communication protocol document for details.
  • GPS/Display Interface: The BMS reserves interfaces for optional GPS modules (for battery location) and display screens (for viewing battery information).

6. Maintenance

To ensure optimal performance and longevity of your JIKONG Smart BMS, follow these maintenance guidelines:

  • Regularly check all wiring connections for tightness and integrity. Loose connections can lead to inaccurate readings or system malfunctions.
  • Keep the BMS and battery pack clean and free from dust, moisture, and corrosive substances.
  • Periodically check the battery cells for any signs of swelling, leakage, or damage.
  • Ensure the BMS is installed in a well-ventilated area to prevent overheating.
  • Keep the mobile APP updated to the latest version to benefit from new features and bug fixes.
  • If the BMS is not in use for an extended period, activate the intelligent sleep function or ensure the battery voltage does not drop below the automatic shutdown threshold.

7. Troubleshooting

This section addresses common issues and their solutions:

Problem Possible Cause / Solution
BMS does not turn on
  • Ensure the last 'B+' line of the cable is connected to the positive pole of the battery.
  • Start up after charging; ensure charger voltage is >4V of battery pack voltage.
  • Check if the charger has voltage output.
Inaccurate voltage readings
  • Measure the actual total battery pack voltage with a multimeter.
  • Enter this actual voltage in the "voltage calibration" setting on the APP's parameter page.
Inaccurate current readings
  • Ensure both B- and P- of the protection board (7AWG wires) are connected in parallel.
  • Measure the actual current with a clamp meter.
  • Enter this actual current in the "current calibration" setting on the APP's parameter page. Higher actual current during calibration improves accuracy.
Inaccurate capacity readings
  • Initial capacity estimation based on monomer voltage can be inaccurate.
  • Calibrate capacity by fully discharging the battery to the cut-off voltage, then fully charging it without interruption.
Designed string number inconsistent with actual string number
  • Check if the "unit quantity" in the parameter settings is correctly set in the APP.
  • If there's no voltage in two or more middle strings, check if the acquisition cable has fallen off.

8. User Tips

  • For optimal balancing, ensure all cell voltages are as close as possible before initial setup.
  • When connecting the BMS for the first time, double-check all wiring to prevent short circuits or damage.
  • Utilize the mobile APP to regularly monitor battery health and adjust parameters as needed for your specific battery pack and application.
  • If experiencing issues with current readings, verify that both B- and P- wires are correctly connected in parallel to avoid errors.
  • For cold environments, consider using a BMS model with the heating function to maintain battery performance and longevity.

9. Warranty and Support

For detailed warranty information, technical support, and further documentation, please refer to the official JIKONG user manual PDF available at JIKONG User Manual (PDF). This document provides comprehensive details on product usage, specifications, and troubleshooting.

You can also find additional resources and protocol information at:

© 2024 JIKONG. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.