ANCEL S110 PRO

ANCEL S110 PRO Car Pipeline Smoke Leak Detector User Manual

Model: S110 PRO

1. Introduction

The ANCEL S110 PRO is a professional automotive smoke leak detector designed to quickly and accurately identify leaks in various vehicle systems. It features a built-in air pump and supports both air and smoke modes for comprehensive diagnostic testing. This manual provides detailed instructions for the safe and effective use of your ANCEL S110 PRO.

ANCEL S110 PRO Smoke Leak Detector with accessories
Figure 1: ANCEL S110 PRO Smoke Leak Detector and included accessories.

2. Package Contents

Please check the package contents upon receipt to ensure all items are present and undamaged:

  • Host Unit (ANCEL S110 PRO) x1
  • Instruction Manual x1
  • Power Cord Clamp x1
  • Delivery Hose x1
  • Hook x1
  • EVAP Adapter x1
  • EVAP Removal Tool x1
  • Funnel x1
Package list for ANCEL S110 PRO
Figure 2: Visual representation of the ANCEL S110 PRO package contents.

3. Product Overview

Familiarize yourself with the main components and controls of the ANCEL S110 PRO:

Labeled diagram of ANCEL S110 PRO components
Figure 3: Key components of the ANCEL S110 PRO.
  • Oil Refill Port: For adding smoke oil.
  • Velcro Strap: For securing the device.
  • Oil Level Gauge: Indicates the current smoke oil level.
  • Power Socket: Connection point for the power cord.
  • Smoke Outlet Port: Where smoke exits the device.
  • Flow Dial: Adjusts the smoke output.
  • Flow Meter: Measures the smoke flow rate.

4. Setup and Operation

Follow these steps to set up and operate your ANCEL S110 PRO for leakage testing:

  1. Fill Smoke Oil: Open the oil refill port and use the provided funnel to add approximately 20ml of smoke oil (baby oil or mineral oil based) into the unit. Ensure the oil level does not exceed the MAX mark on the oil level gauge.
  2. Connect Pipe: Disconnect the vehicle's pipe that needs testing and connect it to the detector's smoke outlet port.
  3. Connect Power: Connect the power cord clamp to a DC 12V battery (red clamp to positive, black clamp to negative).
  4. Power On: Turn on the power switch on the device.
  5. Air Mode Test (Optional): Turn on the air button to check for leaks using air pressure. Observe the floatation of the ball in the flow meter; a stable ball indicates no significant leak, while movement suggests a leak.
  6. Smoke Mode Test: Turn on the smoke button. The pipe will be filled with smoke. Visually inspect the system for any escaping smoke to pinpoint leak points.
  7. Adjust Smoke Output: Use the flow dial to adjust the amount of smoke output as needed for optimal visibility.
Step-by-step guide on how to perform a leakage test
Figure 4: Visual guide for performing a leakage test.
Video 1: Demonstration of the ANCEL S110 PRO setup and leakage testing process.

5. Operating Modes

The ANCEL S110 PRO offers two distinct operating modes for versatile leak detection:

  • Air Mode: Used for a quick initial check to determine if a leak exists. This mode is particularly useful for detecting leaks in smoke-sensitive components. After the test begins, observe the floatation of the ball in the flow meter to judge if there is a leak.
  • Smoke Mode: Once a leak is suspected, switch to smoke mode to generate visible smoke, allowing you to precisely locate the leakage point within the system. Observe whether there is smoke after the test starts to judge the leakage.
Diagram showing Air Mode and Smoke Mode operation
Figure 5: Dual operating mode design for comprehensive leak detection.

6. Applications

The ANCEL S110 PRO is suitable for detecting leaks in various automotive systems, including but not limited to:

  • Cooling System
  • Fuel Tank System
  • Intake System
  • EVAP System (Output pressure of approximately 0.5 PSI)
  • Crankcase System
  • Various Pipes and Hoses
  • Exhaust System
  • Turbo System
  • EGR System
Diagram of vehicle systems supported by ANCEL S110 PRO
Figure 6: Multi-system support for comprehensive vehicle diagnostics.

This device is versatile and can be used across a wide range of vehicles, including cars, motorcycles, trucks, ATVs, snowmobiles, and boats.

Examples of vehicles compatible with ANCEL S110 PRO
Figure 7: Wide range of applications for the smoke leak detector.

7. Key Features

  • Built-in Air Pump: Eliminates the need for an external air compressor, making it ready for diagnosis and maintenance at any time.
  • Overheat Protection: The device is equipped with intelligent power protection that automatically activates and turns off the unit if the temperature exceeds 120°C, preventing damage.
  • Anti-Frost Protection: Designed to operate normally even in temperatures as low as -20°C.
Diagram illustrating the built-in air pump
Figure 8: Internal view highlighting the built-in air pump.
Overheat and anti-frost protection features
Figure 9: Explanation of overheat and anti-frost protection.

8. Specifications

FeatureSpecification
ModelS110 PRO
Output Pressure (EVAP)Approx. 0.5 PSI
Power SupplyDC 12V Vehicle Battery
Operating TemperatureNormal operation down to -20°C
Overheat Protection Trigger120°C
Dimensions (Approx.)Length: 24 cm, Width: 17 cm, Height: 15 cm
Weight (Approx.)1.442 kg

9. Maintenance

To ensure the longevity and optimal performance of your ANCEL S110 PRO, follow these maintenance guidelines:

  • Cleanliness: Keep the device clean and free from dust and debris. Wipe the exterior with a soft, dry cloth.
  • Smoke Oil: Regularly check the smoke oil level using the oil level gauge. Refill with appropriate smoke oil (baby oil or mineral oil based) when low. Do not overfill.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Hoses and Connections: Inspect hoses and connections for any signs of wear, cracks, or damage before each use. Replace if necessary to ensure proper sealing and prevent leaks.
  • Power Cables: Check the power cord clamps and cables for damage. Ensure secure connections during operation.

10. Troubleshooting

If you encounter issues with your ANCEL S110 PRO, refer to the following common troubleshooting steps:

  • No Smoke Output:
    • Check if the device is properly connected to a 12V DC power source.
    • Ensure the power switch is turned ON.
    • Verify that there is sufficient smoke oil in the reservoir.
    • Check if the smoke button is activated.
    • Inspect the smoke outlet port and hose for blockages.
  • Weak Smoke Output:
    • Adjust the flow dial to increase smoke output.
    • Ensure the smoke oil level is adequate.
    • Check for any kinks or obstructions in the delivery hose.
  • Device Not Powering On:
    • Confirm the power clamps are securely connected to the vehicle battery terminals (red to positive, black to negative).
    • Check the vehicle battery for sufficient charge.
    • Inspect the power cable for any damage.
  • Overheat Protection Activated:
    • If the device automatically shuts off, allow it to cool down before resuming operation. Ensure adequate ventilation around the unit.

If the problem persists after trying these steps, please contact customer support.

11. User Tips

Here are some tips for getting the most out of your ANCEL S110 PRO:

  • For best results, perform leak tests in a well-ventilated area.
  • Always ensure the engine is off and cool before connecting the smoke leak detector.
  • Use the appropriate adapters for different pipe sizes to ensure a tight seal.
  • When using smoke mode, allow a few moments for the smoke to fill the system before inspecting for leaks.
  • Keep a supply of suitable smoke oil on hand for continuous use.

12. Warranty and Support

The ANCEL S110 PRO is designed for durability and reliability. For specific warranty information, please refer to the warranty card included in your package or contact the manufacturer directly. For technical support or service inquiries, please reach out to ANCEL customer service through their official channels.

Related Documents - S110 PRO

PreviewAutomotive Diagnostic Smoke Leak Detector User Manual - Ancel S200/S300
Comprehensive user manual for the Ancel Automotive Diagnostic Smoke Leak Detector (models S200 and S300). Learn about its features, specifications, parts, operation, troubleshooting, and warranty for effective vehicle leak detection.
PreviewANCEL Automotive Diagnostic Smoke Leak Detector User's Manual
Comprehensive user manual for the ANCEL Automotive Diagnostic Smoke Leak Detector, covering its features, operation, accessories, specifications, troubleshooting, and EVAP system knowledge.
PreviewANCEL Automotive Diagnostic Smoke Leak Detector User Manual
Comprehensive user manual for the ancel Automotive Diagnostic Smoke Leak Detector, covering operation, specifications, troubleshooting, and warranty information. Learn how to effectively test various vehicle pipeline systems for leaks.
PreviewANCEL Automotive Diagnostic Smoke Leak Detector User Manual
User manual for the ANCEL Automotive Diagnostic Smoke Leak Detector, providing detailed information on its features, operation, accessories, specifications, troubleshooting, and EVAP system testing for automotive diagnostics.
PreviewANCEL Automotive Diagnostic Leak Detector User Manual
User manual for the ANCEL Automotive Diagnostic Leak Detector, detailing its specifications, packing list, components, operation, and warranty.
PreviewANCEL AD310 OBD II Scan Tool User Manual
Comprehensive user manual for the ANCEL AD310 OBD II scan tool, detailing its features, operation, safety precautions, diagnostic functions, and warranty information.