1. Introduction
The MESTEK EMF02R is a versatile 3-in-1 Electromagnetic Field (EMF) meter designed for detecting high-frequency radiation, electric fields, and magnetic fields. It also features integrated temperature and humidity measurement capabilities. Equipped with a high-definition VA color screen, it provides clear digital and analog dual displays for easy interpretation of readings. This device is suitable for a wide range of applications, including residential, office, industrial, and specialized environments like power distribution rooms, high-speed rail, and signal base stations.
2. Key Features
- Three-Axis Signal Detection: Utilizes a highly sensitive three-axis sensing probe (X-axis, Y-axis, Z-axis) for comprehensive radiation detection.
- Temperature and Humidity Measurement: Features 12 air vents on the back sensor for accurate measurement of ambient temperature and humidity.
- High-Definition VA Color Screen: Provides an ultra-clear digital and analog dual display for easy readability.
- USB Type-C Charging: Equipped with a built-in 2000mAh 3.7V lithium battery, rechargeable via a 5V/1A USB Type-C cable (approximately 4 hours for a full charge).
- Multi-Purpose Display: Suitable for various environments including homes, offices, industrial settings, power distribution rooms, high-speed rail, and signal base stations.
- Measurement Modes: Supports RF (Radio Frequency), E-field (Electric Field), and H-field (Magnetic Field) detection.
- Data Functions: Includes Maximum (MAX), Average (AVG), and Data Hold (HOLD) functions.
- Alarm Function: Features a sound alarm and analog bar display for excessive radiation levels.
- Automatic Shutdown: Powers off automatically after approximately 15 minutes of inactivity to conserve battery.
3. Package Contents
Please check the package for the following items:
- 1 x MESTEK EMF02R High Frequency Radiation Detector
- 1 x USB Type-C Charging Cable
- 1 x Storage Bag
- 1 x Instruction Manual (this document)

4. Product Overview
Familiarize yourself with the components and controls of your EMF Meter:

4.1 Key Functions

| Symbol | Description |
|---|---|
![]() | Power button |
| SEL | Function conversion key (e.g., between E-field, H-field) |
| AVG/MAX | Average and maximum value conversion keys |
| HOLD | Data lock key |
![]() | Ring tone on/off key (Buzzer switch) |
| RF | High frequency signal conversion key |
5. Setup and Charging
5.1 Initial Charge
Before first use, or if the battery indicator on the screen shows low battery, charge the device fully. The built-in 18650/2000mAh 3.7V lithium battery takes approximately 4 hours to fully charge using the provided 5V/1A USB Type-C charging cable.

Important Charging Notes:
- Use an adapter that meets relevant safety certification requirements for charging in a well-ventilated and heat-dissipating environment.
- When the instrument screen displays a low battery icon, charge the instrument as soon as possible.
- During the charging process, the instrument will automatically shut down and cannot be started. It can be used normally after the charging is completed or stopped.
6. Operating Modes
The EMF02R features a high-frequency electromagnetic radiometer using precision sensors for accurate detection of various electromagnetic radiation types.

6.1 RF (High Frequency) Measurement
- Short press the RF button to enter high-frequency signal radiation measurement mode.
- This mode can measure base stations between 30MHz and 8GHz high-frequency signals.
6.2 E-field (Electric Field) Measurement
- Short press the SEL key to display "E-field" on the screen, entering electric field radiation measurement mode.
- Measures the electric field radiation value of electrical equipment.
6.3 H-field (Magnetic Field) Measurement
- Short press the SEL key again to display "H-field" on the screen, entering electromagnetic field radiation measurement mode.
- Press the SEL button to convert electromagnetic field radiation measurement units (mG milliGauss → uT micro Tesla).
- Measures the electromagnetic radiation values of electrical equipment.
6.4 Temperature and Humidity Measurement
The device automatically displays temperature and humidity readings on the screen, utilizing the 12 air vents on the back for precise environmental sensing.

7. Screen Display and Indicators
The VA reverse display color screen provides a clear overview of all measurements and device status.

| Symbol | Description | Unit | Meaning |
|---|---|---|---|
![]() | Battery Indicator | Indicates current battery level | |
![]() | Automatic shutdown | Indicates automatic shutdown feature is active | |
![]() | Simulated display | Analog bar graph for radiation intensity | |
| AVG | Average value | Displays the average measurement | |
| MAX | Maximum value | Displays the maximum measurement | |
| HOLD | Data locking | Freezes the current reading on screen | |
| RF | Radio frequency | uW/cm² | Microwatt per square centimeter |
| H-field | Magnetic field | uT, mG | Micro Teslas, MilliGauss |
| E-field | Electric field | V/m | Volts per meter |
![]() | Temperature | ℃, ℉ | Celsius, Fahrenheit degree |
![]() | Humidity | % | Percentage |
![]() | Ringtones | Indicates alarm sound status |
7.2 Radiation Area Comparison Table
The device uses a color-coded analog display to indicate radiation levels:

| Analog Display | Green | Yellow | Red |
|---|---|---|---|
| uW/cm² | 0.0 - 39.9 | 40 - 99.9 | 100 - 9999 |
| V/m | 0 - 39 | 40 - 399 | 400 - 999 |
| mG | 0.0 - 3.9 | 4.0 - 39.9 | 40.0 - 199.9 |
| uT | 0.00 - 0.39 | 0.40 - 3.99 | 4.00 - 19.99 |
8. Specifications

| Parameter | Value |
|---|---|
| Working Height | 2000m |
| Measurement Mode | Electromagnetic induction, RF radio frequency receiving sensor |
| Display | VA reverse color screen |
| Maximum Display | 9999 |
| Sampling Rate | About 0.4 seconds |
| Measuring Range | V/m: 0~999 / uT: 0.00~19.99 / mG: 0.0~199.9 / uW/cm²: 0.0~9999 |
| Test Bandwidth | 30MHz~8GHz |
| Resolution | V/m: 1 / uT: 0.01 / mG: 0.1 / uW/cm²: 0.1 / ℃: 0.1 / ℉: 0.2 / %RH: 1 |
| Alarm Mode | Sound, analog bar |
| Automatic Shutdown | Approx. 15 minutes |
| Operating Current | Approx. 50mA |
| Charging Interface | USB Type-C |
| USB Charging | 5V/1A |
| Power Supply | Built-in 18650 / 2000mA / 3.7V lithium battery |
| Charging Time | About 4 hours |
| Temperature Measurement Range | 0~50℃ |
| Humidity Measurement Range | 0~90%RH |
| Working Temperature and Humidity | 0~50℃ / 0~90%RH |
| Storage Temperature and Humidity | -10~60℃ / 0~80%RH |
| Size | 204 x 63 x 32mm |
| Weight | Approximately 220g |
9. User Tips
- The device is capable of measuring frequencies within the 30MHz to 8GHz range and clearly displays the corresponding units on the screen.
- For accurate temperature and humidity readings, ensure the 12 air vents on the back of the device are not obstructed.
- When the analog display bar reaches the yellow area, the instrument will alarm, indicating excessive radiation. Consider taking protective measures or moving away from the radiation source.
10. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage temperature is -10~60℃ and humidity is 0~80%RH.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device when the low battery indicator appears.
- Avoid Impact: Protect the device from drops and strong impacts, especially the induction probe.
11. Troubleshooting
- Device does not power on: Ensure the battery is charged. Connect the device to a power source using the USB Type-C cable and allow it to charge for at least 30 minutes before attempting to power on again.
- Inaccurate readings: Ensure the device is held steadily and away from strong interference sources. Check that the induction probe is not obstructed or damaged. For temperature/humidity, ensure air vents are clear.
- Screen is blank or frozen: Try restarting the device by holding the power button. If unresponsive, allow the battery to fully discharge and then recharge.
- Alarm sounds frequently: This indicates high radiation levels. Refer to the Radiation Area Comparison Table (Figure 7.2) to understand the severity and consider moving away from the source.
12. Warranty and Support
This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. Please retain your proof of purchase for warranty claims. For technical support, troubleshooting assistance, or warranty inquiries, please contact the retailer or manufacturer's customer service department.
Do not attempt to repair the device yourself, as this may void the warranty and could lead to injury or damage to the device.