MESTEK EMF02R

Contents

MESTEK EMF02R 3-In-1 Color Screen EMF Meter User Manual

Model: EMF02R

1. Introduction

The MESTEK EMF02R is a versatile 3-in-1 Electromagnetic Field (EMF) meter designed for detecting high-frequency radiation, electric fields, and magnetic fields. It also features integrated temperature and humidity measurement capabilities. Equipped with a high-definition VA color screen, it provides clear digital and analog dual displays for easy interpretation of readings. This device is suitable for a wide range of applications, including residential, office, industrial, and specialized environments like power distribution rooms, high-speed rail, and signal base stations.

2. Key Features

  • Three-Axis Signal Detection: Utilizes a highly sensitive three-axis sensing probe (X-axis, Y-axis, Z-axis) for comprehensive radiation detection.
  • Temperature and Humidity Measurement: Features 12 air vents on the back sensor for accurate measurement of ambient temperature and humidity.
  • High-Definition VA Color Screen: Provides an ultra-clear digital and analog dual display for easy readability.
  • USB Type-C Charging: Equipped with a built-in 2000mAh 3.7V lithium battery, rechargeable via a 5V/1A USB Type-C cable (approximately 4 hours for a full charge).
  • Multi-Purpose Display: Suitable for various environments including homes, offices, industrial settings, power distribution rooms, high-speed rail, and signal base stations.
  • Measurement Modes: Supports RF (Radio Frequency), E-field (Electric Field), and H-field (Magnetic Field) detection.
  • Data Functions: Includes Maximum (MAX), Average (AVG), and Data Hold (HOLD) functions.
  • Alarm Function: Features a sound alarm and analog bar display for excessive radiation levels.
  • Automatic Shutdown: Powers off automatically after approximately 15 minutes of inactivity to conserve battery.

3. Package Contents

Please check the package for the following items:

  • 1 x MESTEK EMF02R High Frequency Radiation Detector
  • 1 x USB Type-C Charging Cable
  • 1 x Storage Bag
  • 1 x Instruction Manual (this document)
MESTEK EMF02R product accessories including the detector, USB-C cable, storage bag, and manual.
Figure 3.1: Product Accessories

4. Product Overview

Familiarize yourself with the components and controls of your EMF Meter:

Diagram of MESTEK EMF02R showing induction probe, display screen, function keys, charging indicator light, and Type-C charging port with dimensions.
Figure 4.1: Front and Side View with Labeled Parts

4.1 Key Functions

Close-up of the MESTEK EMF02R buttons: Power, SEL, AVG/MAX, HOLD, Buzzer, RF.
Figure 4.2: Function Keys
SymbolDescription
Power button iconPower button
SELFunction conversion key (e.g., between E-field, H-field)
AVG/MAXAverage and maximum value conversion keys
HOLDData lock key
Buzzer iconRing tone on/off key (Buzzer switch)
RFHigh frequency signal conversion key

5. Setup and Charging

5.1 Initial Charge

Before first use, or if the battery indicator on the screen shows low battery, charge the device fully. The built-in 18650/2000mAh 3.7V lithium battery takes approximately 4 hours to fully charge using the provided 5V/1A USB Type-C charging cable.

MESTEK EMF02R connected to a wall adapter via USB Type-C cable, showing 'Charging' (red) and 'Full' (green) indicators.
Figure 5.1: USB Type-C Charging

Important Charging Notes:

  • Use an adapter that meets relevant safety certification requirements for charging in a well-ventilated and heat-dissipating environment.
  • When the instrument screen displays a low battery icon, charge the instrument as soon as possible.
  • During the charging process, the instrument will automatically shut down and cannot be started. It can be used normally after the charging is completed or stopped.

6. Operating Modes

The EMF02R features a high-frequency electromagnetic radiometer using precision sensors for accurate detection of various electromagnetic radiation types.

Diagram illustrating RF, E-field, and H-field measurement modes with examples like base stations, electrical equipment, and high-speed rail.
Figure 6.1: Measurement Modes

6.1 RF (High Frequency) Measurement

  • Short press the RF button to enter high-frequency signal radiation measurement mode.
  • This mode can measure base stations between 30MHz and 8GHz high-frequency signals.

6.2 E-field (Electric Field) Measurement

  • Short press the SEL key to display "E-field" on the screen, entering electric field radiation measurement mode.
  • Measures the electric field radiation value of electrical equipment.

6.3 H-field (Magnetic Field) Measurement

  • Short press the SEL key again to display "H-field" on the screen, entering electromagnetic field radiation measurement mode.
  • Press the SEL button to convert electromagnetic field radiation measurement units (mG milliGauss → uT micro Tesla).
  • Measures the electromagnetic radiation values of electrical equipment.

6.4 Temperature and Humidity Measurement

The device automatically displays temperature and humidity readings on the screen, utilizing the 12 air vents on the back for precise environmental sensing.

Close-up of the back of the MESTEK EMF02R showing temperature and humidity readings and the 12 air vents.
Figure 6.2: Temperature and Humidity Display

7. Screen Display and Indicators

The VA reverse display color screen provides a clear overview of all measurements and device status.

Detailed screen display of MESTEK EMF02R showing HOLD, MAX, AVG, E-field, H-field, RF indicators, numerical readings, units (uT, mG, V/m, uW/cm²), temperature, humidity, battery, and alarm icons.
Figure 7.1: Screen Display Overview
SymbolDescriptionUnitMeaning
Battery indicator iconBattery IndicatorIndicates current battery level
Automatic shutdown iconAutomatic shutdownIndicates automatic shutdown feature is active
Simulated display bar iconSimulated displayAnalog bar graph for radiation intensity
AVGAverage valueDisplays the average measurement
MAXMaximum valueDisplays the maximum measurement
HOLDData lockingFreezes the current reading on screen
RFRadio frequencyuW/cm²Microwatt per square centimeter
H-fieldMagnetic fielduT, mGMicro Teslas, MilliGauss
E-fieldElectric fieldV/mVolts per meter
Temperature iconTemperature℃, ℉Celsius, Fahrenheit degree
Humidity iconHumidity%Percentage
Ringtone iconRingtonesIndicates alarm sound status

7.2 Radiation Area Comparison Table

The device uses a color-coded analog display to indicate radiation levels:

Radiation area comparison table showing Green, Yellow, and Red ranges for uW/cm², V/m, mG, and uT units.
Figure 7.2: Radiation Level Indicator
Analog DisplayGreenYellowRed
uW/cm²0.0 - 39.940 - 99.9100 - 9999
V/m0 - 3940 - 399400 - 999
mG0.0 - 3.94.0 - 39.940.0 - 199.9
uT0.00 - 0.390.40 - 3.994.00 - 19.99

8. Specifications

Table of technical parameters for MESTEK EMF02R including working height, measurement method, display, max display, sampling rate, measuring range, test bandwidth, resolution, alarm mode, auto shutdown, operating current, charging interface, USB charging, power supply, charging time, temperature/humidity ranges, working/storage conditions, size, and weight.
Figure 8.1: Technical Parameters
ParameterValue
Working Height2000m
Measurement ModeElectromagnetic induction, RF radio frequency receiving sensor
DisplayVA reverse color screen
Maximum Display9999
Sampling RateAbout 0.4 seconds
Measuring RangeV/m: 0~999 / uT: 0.00~19.99 / mG: 0.0~199.9 / uW/cm²: 0.0~9999
Test Bandwidth30MHz~8GHz
ResolutionV/m: 1 / uT: 0.01 / mG: 0.1 / uW/cm²: 0.1 / ℃: 0.1 / ℉: 0.2 / %RH: 1
Alarm ModeSound, analog bar
Automatic ShutdownApprox. 15 minutes
Operating CurrentApprox. 50mA
Charging InterfaceUSB Type-C
USB Charging5V/1A
Power SupplyBuilt-in 18650 / 2000mA / 3.7V lithium battery
Charging TimeAbout 4 hours
Temperature Measurement Range0~50℃
Humidity Measurement Range0~90%RH
Working Temperature and Humidity0~50℃ / 0~90%RH
Storage Temperature and Humidity-10~60℃ / 0~80%RH
Size204 x 63 x 32mm
WeightApproximately 220g

9. User Tips

  • The device is capable of measuring frequencies within the 30MHz to 8GHz range and clearly displays the corresponding units on the screen.
  • For accurate temperature and humidity readings, ensure the 12 air vents on the back of the device are not obstructed.
  • When the analog display bar reaches the yellow area, the instrument will alarm, indicating excessive radiation. Consider taking protective measures or moving away from the radiation source.

10. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage temperature is -10~60℃ and humidity is 0~80%RH.
  • Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device when the low battery indicator appears.
  • Avoid Impact: Protect the device from drops and strong impacts, especially the induction probe.

11. Troubleshooting

  • Device does not power on: Ensure the battery is charged. Connect the device to a power source using the USB Type-C cable and allow it to charge for at least 30 minutes before attempting to power on again.
  • Inaccurate readings: Ensure the device is held steadily and away from strong interference sources. Check that the induction probe is not obstructed or damaged. For temperature/humidity, ensure air vents are clear.
  • Screen is blank or frozen: Try restarting the device by holding the power button. If unresponsive, allow the battery to fully discharge and then recharge.
  • Alarm sounds frequently: This indicates high radiation levels. Refer to the Radiation Area Comparison Table (Figure 7.2) to understand the severity and consider moving away from the source.

12. Warranty and Support

This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. Please retain your proof of purchase for warranty claims. For technical support, troubleshooting assistance, or warranty inquiries, please contact the retailer or manufacturer's customer service department.

Do not attempt to repair the device yourself, as this may void the warranty and could lead to injury or damage to the device.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.