1. Product Overview
The KeepLiNK KP-9000-9XHP-X is a 9-Port Multi-Gigabit PoE Switch designed for high-speed network connectivity. It features 8x 2.5Gb PoE+ ports and 1x 10Gb SFP+ port for uplink, offering versatile application in various environments such as offices, hotels, dormitories, and homes. This unmanaged switch is plug-and-play, requiring no complex configuration or software. It boasts a fan-less design for silent operation and is built with a durable metal housing for effective heat dissipation and longevity.

Figure 1: Front view of the KeepLiNK 9-Port Multi-Gigabit PoE Switch
Video 1: Product overview showcasing the switch's features and design.
2. Packing List
Please check the contents of your package upon receipt. If any items are missing or damaged, contact customer support.
- KeepLiNK 9-Port Multi-Gigabit PoE Switch (KP-9000-9XHP-X)
- AC power cord (for built-in power supply)
- User manual
- Certificate of conformity
- Hanging ears and screws (for rack-mounted devices)

Figure 2: Rear view of the switch with power input and a list of key features.
3. Setup
3.1 Installation Precautions
To ensure optimal performance and safety, observe the following precautions:
- Network Cable Selection:
- For 100Mbps connections, use Cat5 or above Ethernet cable.
- For 1000Mbps/2.5GE/5GE connections, use Cat5e or above Ethernet cable.
- For 10GE speed connections, use Cat6a or above Ethernet cable.
- Fiber Optic Cable:
- Fiber optics and connectors must be used with compatible optical modules.
- Ensure the bending radius of the optical fiber is not less than 40mm.
3.2 Safety Precautions for Equipment Installation
- Always power off the device before installation.
- Ensure the power supply voltage matches the switch's requirements (AC Input 100-240V).
- Do not overload the power circuit to prevent operational issues.
- Never open the switch casing while it is in operation to avoid electric shock.
3.3 Precautions for Equipment Installation Environment
- Maintain a stable temperature and humidity to ensure long-term operation and prevent material degradation.
- Regularly remove dust and ensure good grounding to prevent static electricity interference.
- Keep the switch away from high-frequency, high-power, and high-current equipment to avoid electromagnetic interference.
- For outdoor wiring, use signal lightning protectors and ensure proper grounding of the rack and power sockets to prevent damage from lightning strikes.
3.4 Switch Installation Methods
The switch supports desktop, rack, and wall-mounted installations.
3.4.1 Rack Mounted Installation
- Attach the provided hanging ears to both ends of the device using screws.
- Slide the device parallel into the cabinet tray and secure it with cabinet screws.

Figure 3: Rack-mounted installation diagram.
3.4.2 Desktop Installation
Place the switch on a flat, stable surface. Ensure adequate ventilation and heat dissipation space around the device. Do not place heavy objects on the switch.
3.4.3 Wall Mounting Installation
- Fix screws on the wall according to the position of the wall mounting holes on the device. Ensure a distance of 3mm ± 0.5mm between the nuts and the wall.
- Align the wall mounting holes on the device with the screws for installation and fixation.

Figure 4: Wall-mounted installation diagram.
4. Operating
4.1 Product Indicator Lights
The switch features various indicator lights to provide real-time status information:
| Sign | Definition | Status | Description |
|---|---|---|---|
| PWR/P | Power indicator light | Green light always on/off | Power is connected/not connected |
| AI PoE | AI light | Green light on/off | AI PoE started/not started |
| SYS/NMS/S/N | System light | Green light on/off | System working/system not started |
| 100Mbps copper port Connection status indicator light | Left light Speed | Yellow light always on | 100M speed |
| Yellow light off | 10M speed | ||
| Right light Link/act | Green light always on | Port connected | |
| Green light off | Port not connected | ||
| Green light blink | The port is connected and there is data transmission and reception | ||
| 1000Mbps copper port Connection status indicator light | Left light Speed | Yellow light always on | 1000M speed |
| Yellow light off | 10/100M speed | ||
| Right light Link/act | Green light always on | Port connected | |
| Green light off | Port not connected | ||
| Green light blink | The port is connected and there is data transmission and reception | ||
| 2.5G copper port Connection status indicator light | Left light Speed | Yellow light on | 2.5G speed |
| Yellow light off or green light always on | 10/100/1000M speed | ||
| Right light Link/act | Green light always on | Port connected or 10/100/1000M speed | |
| Green light off | Port not connected | ||
| Light blink | The port is connected and there is data transmission and reception | ||
| 10G copper port Connection status indicator light | Left light Speed | Yellow light on | 10G speed |
| Green light on | 5G speed | ||
| Light blink | Data transmission and reception | ||
| 10G downlink fiber port Connection status indicator light | Link/act | Yellow light always on | 10G speed |
| Green light always on | 1G rate | ||
| Light off | Port not connected | ||
| Light blink | The port is connected and there is data transmission and reception | ||
| Optical port connection status indicator light | Link/act | Green light on | Port connected |
| Green light off | Port not connected |
4.2 PoE Powered Function
This switch supports standard PoE power supply (IEEE802.3af/at protocol) on ports 1-8. It can automatically detect and provide power to standard PoE devices. Non-PoE devices will only transmit data without receiving power.
- PoE Protocol: IEEE802.3af (15.4W), IEEE802.3at (30W)
- PoE Pinout: 1,2+/3,6-
- Max. PoE Power for Each Port: 30W
- PoE Power Budget: 135W

Figure 5: Standard PoE compliance for powering devices.
4.3 WEB Management (for Managed Switches only)
This switch is an unmanaged device and does not support WEB management. The information below is for reference only for managed switch models.
- Connect the device to a PC and ensure initialization is complete.
- Configure the IP address of the PC and the default IP address of the switch to be in the same network segment.
- Input "http://192.168.1.168" into a PC browser. Enter the default username "admin" and password "admin" to log in.

Figure 6: Example of a WEB management login interface.
4.4 Console Port Management (for Managed Switches only)
This switch is an unmanaged device and does not support Console Port management. The information below is for reference only for managed switch models.
- Use a console port cable to connect the console port of the PC and switch.
- Open terminal simulation software, establish a connection, select the serial port, and set communication parameters: Transmission rate: 115200, Data bit: 8, Check digit: None, Stop bit: 1, Flow control method: None.
5. Maintenance
To ensure the longevity and stable operation of your KeepLiNK switch, regular maintenance is recommended:
- Environmental Control: Maintain a stable temperature and humidity in the operating environment. Avoid extreme conditions that could lead to insulation material leakage, deformation, or metal corrosion.
- Dust Removal: Periodically clean the device to prevent dust accumulation, which can affect performance and lead to static electricity issues.
- Grounding: Ensure the equipment is properly grounded to prevent static electricity and enhance safety.
- Cable Management: Keep network and power cables organized and free from kinks or excessive bending to maintain signal integrity and prevent damage.
6. Troubleshooting
If you encounter issues with your KeepLiNK switch, consider the following:
- No Power: Check the power indicator light (PWR/P). If it's off, ensure the power cord is securely connected and the power source is active.
- No Link/Activity: Check the Link/Act indicator lights for the specific port. If off, ensure the Ethernet cable is properly connected to both the switch and the connected device. If blinking, data transmission is occurring.
- Incorrect Speed: Observe the speed indicator lights (Left light Speed). If the speed is lower than expected, verify the connected device supports the desired speed (e.g., 2.5G) and that the correct cable type (e.g., Cat6a for 10GE) is used.
- PoE Device Not Powering On: Ensure the connected device is a standard PoE device (IEEE802.3af/at compliant). Check the AI PoE indicator light. If it's off, the AI PoE function might not be active or the device is not detected as PoE.
- Network Performance Issues: Verify that the network environment meets the recommended conditions (temperature, humidity, absence of strong electromagnetic interference). Ensure proper cable types are used for the respective speeds.
7. Specifications
| Attribute | Value |
|---|---|
| Brand Name | keepLiNK |
| Model Number | KP-9000-9XHP-X |
| Number of Interfaces | 10 (8x 2.5Gb PoE, 1x 10Gb SFP+) |
| Transmission Rate | 10000 Mbps (10Gbps) |
| Switch Capacity | 60Gbps |
| Communication Mode | Full-Duplex & Half-Duplex |
| Function | POE, VLAN Support |
| Certification | CE, FCC, RoHS |
| PoE Protocol | IEEE802.3af/at |
| PoE Power Budget | 135W |
| PoE Pinout | 1,2,3,6 |
| Max. PoE Power for Each Port | 30W |
| Origin | Mainland China |
| Package | Yes |
| High-concerned chemical | none |
| VLAN | Yes |
7.1 Detailed Specifications

Figure 7: Detailed specifications including interfaces, power, and PoE parameters.

Figure 8: Further specifications including switch properties, environmental limits, physical characteristics, and standards.
8. Warranty and Support
8.1 After-sales Service Letter of Commitment
Within seven days from the date of sale, if the entire device fails, you may choose to repair, replace, or return it. If a performance failure occurs within seven days to one year from the date of sale (based on the purchase invoice), the device is eligible for repair or replacement. Beyond the one-year hardware warranty period, the cost of replacing hardware will be borne by the user, with no additional company costs.
8.2 Circumstances Not Covered by Warranty
The warranty does not cover equipment failure or damage under the following circumstances:
- Accessories supplied by other companies (e.g., power supply, adapter) are covered by their respective manufacturers' warranties.
- The entire machine and parts have exceeded their warranty period.
- Equipment failure or damage caused by unauthorized repair, alteration, or demolition.
- Malfunctions caused by accidental or artificial causes, including improper operation, scratching, handling, moving, knocking, or incorrect voltage input.
- Failure or damage caused by the use of non-genuine or unpublished software.
- Failures or losses caused by natural disasters (e.g., earthquakes, fires).
8.3 Additional Resources
A detailed user manual in PDF format is available here.
9. User Tips
- Performance: Users consistently report that the switch delivers expected speeds, with some noting an increase in home network speed up to 2500 MBit/s when connected devices support it.
- Silent Operation: The fan-less design is highly appreciated, making it suitable for environments where noise is a concern.
- PoE Applications: This switch is ideal for powering PoE surveillance cameras, IoT devices, and even Unifi access points without issues.
- Plug-and-Play: Being an unmanaged switch, it requires no complex configuration, making setup very easy.
- Physical Size: Some users note that the switch might be slightly thicker than some Western counterparts, which is likely due to its fan-less design relying on the metal casing for heat dissipation.
- Rackmount Ears: The product includes rackmount ears for convenient installation in network racks.