Introduction
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your VEVOR 1300LBS Automatic Sliding Gate Opener. Designed for heavy-duty sliding gates up to 1300 lbs (600 kg) and a maximum length of 12 meters (39 ft), this opener is suitable for various applications including residential, commercial, and industrial settings. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.
Setup and Installation
The VEVOR Automatic Sliding Gate Opener is designed for straightforward installation without the need for an electrician or welding. The kit includes all necessary hardware and fittings. For a visual guide, please refer to the installation video below.
Video: Installation guide for the VEVOR Gear Rack Gate Opener.
Package Contents:
- 1 x Automatic Gate Opener Operator Main Engine
- 2 x Remote Controls (Batteries not included; requires 27A/12V battery)
- 2 x Release Keys
- 8 x 0.5 m (8x1.6') of Metal Racks (Total 4 meters / 13 feet)
- 1 x Photocell Set
- 1 x Installation Accessory Set
Installation Steps:
- Unboxing: Carefully remove the main engine and all accessories from the packaging.
- Prepare the Motor: Remove the housing of the machine to access the internal components for mounting and wiring.
- Mounting the Base: Place the bottom board of the machine in the desired position. Mark the drilling points (approx. 10mm diameter) and drill holes. Secure the machine using M8 anchoring screws and washers.
- Install Gear Rack: Attach the gear rack sections to your gate. Ensure the gear rack and the motor's gear are at the same height for smooth operation. Secure the gear rack firmly.
- Install Limit Switches/Magnets: The kit includes two magnets for position limiting. Install one limited block on the right side of the gate and another on the left. Note that the two magnets have different installation heights (one on top, one under it) to correctly signal the opener's stop positions.
- Wiring: Connect the power supply and any optional accessories (e.g., photocells) to the control board as per the wiring diagram provided in the full manual (not included here).
- Initial Testing (Manual): Before powering on, use the provided keys to set the machine into 'empty space' (manual mode). Open and close the gate by hand to ensure it runs smoothly and there are no obstructions. Adjust as necessary. This manual override is also useful during power outages.
- Remote Control Pairing: Power on the unit. To pair a new remote, press the setting button on the control board (refer to the video for location). Then, press one of the buttons on the remote control. The remote should successfully match.
- Direction Switch: If the motor runs in the opposite direction (e.g., opens when it should close), use the direction switch button on the control board to reverse the motor's operation. If the gate opens from the left and you need it to open from the right, you may need to exchange the positions of the magnets.
- Final Assembly: Install the side cover and the housing of the machine, tightening all screws securely.

Image: Easy Installation Diagram
Operating Instructions
Remote Control Operation:
Your gate opener comes with two 4-button wireless remote controls. These remotes allow you to open, close, and stop the gate from a distance of up to 100 ft (30 m).
- Open Button: Press to open the gate.
- Close Button: Press to close the gate.
- Stop Button: Press to stop the gate's movement at any point.

Image: 100FT Remote Control
Manual Override:
In case of a power outage or system malfunction, you can manually operate the gate using the provided release keys. Insert the key into the manual release lock and turn it to disengage the motor, allowing you to push the gate open or closed by hand.
Maintenance
Regular maintenance ensures the longevity and optimal performance of your gate opener.
- Cleanliness: Keep the gear rack and motor area free from dirt, debris, and obstructions.
- Lubrication: Periodically check and lubricate the moving parts, especially the gear rack and motor gear, to ensure smooth operation.
- Obstruction Check: Regularly inspect the gate's path for any potential obstructions that could interfere with its movement.
- Fastener Check: Ensure all mounting bolts and screws are tight.
- Remote Batteries: Replace remote control batteries (27A/12V) as needed to maintain reliable operation.
Troubleshooting
Here are some common issues and their potential solutions:
- Gate Not Opening/Closing:
- Check power supply.
- Ensure remote control batteries are not depleted.
- Verify that the manual release is fully engaged (not in manual override mode).
- Inspect for physical obstructions in the gate's path.
- Check if the limit switches are correctly positioned and functioning.
- Motor Overheating: The motor has a temperature protector. If it overheats, it may temporarily shut down. Allow it to cool down. Ensure the gate is not too heavy or encountering excessive resistance.
- Gate Stops or Reverses Unexpectedly: This model features a shock-proof stroke design. If the gate encounters an obstruction during opening or closing, it will stop and reverse. Clear any obstructions.
- Remote Control Not Working:
- Replace remote batteries.
- Re-pair the remote control with the main unit (refer to Setup section).
- Ensure you are within the 100 ft (30 m) operating range.
- Motor Runs in Wrong Direction: Use the direction switch button on the control board to correct the motor's direction. You may also need to adjust the positions of the limit magnets.
Specifications

Image: Product Specifications
| Attribute | Value |
|---|---|
| Power Supply | 220 V AC, 50 Hz, 370W |
| Maximum Gate Weight | 600 kg (1300 lb) |
| Maximum Gate Length | 12 m (39 ft) |
| Output Torque | 18 N.m |
| Gate Moving Speed | 13 m/min (43 ft/min) |
| Work Duty | S2, 15 minutes |
| Remote Control Range | ≥30 m (100 ft) |
| Recording of Remote Controls | 25 (2 included) |
| Nylon Gear Rack | 4 m (13 ft) |
| Gross Weight | 17.3 kg (38.2 lb) |
| Certification | CE |
| Origin | Mainland China |
User Tips
- Regular Inspection: Periodically check the gate and opener for any signs of wear, damage, or loose components.
- Clear Path: Always ensure the gate's path is clear of people, pets, and objects before operating.
- Manual Override Readiness: Keep the release keys in an easily accessible but secure location for manual operation during power outages or emergencies.
- Remote Battery Life: If your remote's range decreases, it might be time to replace the 27A/12V battery.
- Quiet Operation: The opener is designed for quiet operation (less than 56 dB). If you notice unusual noises, inspect for issues.
Warranty and Support
For warranty information, technical support, or service inquiries, please contact VEVOR customer service directly through their official website or the retailer where you purchased the product. Ensure you have your product model (PY600AC) and purchase details available when contacting support.