Veinasa Mini-C5A

Contents

Veinasa Mini-C5A 5-in-1 Ultrasonic Weather Sensor User Manual

Model: Mini-C5A | Brand: Veinasa

1. Product Introduction

The Veinasa Mini-C5A is a compact, highly integrated 5-in-1 ultrasonic weather sensor designed for precise measurement of wind speed, wind direction, air temperature, air humidity, and atmospheric pressure. This full digital sensor features a small size, high integration, light weight, and strong durability.

Utilizing a low-power chip and low-power electricity, the conventional 5-element power consumption is only 0.3W, making it especially suitable for environments with high power consumption requirements, such as solar or battery-powered systems. Its new design results in a more compact structure, with a diameter of 80mm and a height of 100mm.

The Mini-C5A operates without any moving parts, eliminating the need for on-site maintenance and calibration. It accurately and quickly detects environmental conditions and is built with a high-strength structure for reliable performance in harsh weather. This sensor is widely applicable in fields such as meteorology, environmental monitoring, transportation, smart cities, and industrial testing.

Veinasa Mini-C5A Ultrasonic Weather Sensor
Figure 1: Veinasa Mini-C5A Ultrasonic Weather Sensor
Video 1: Product demonstration of the Veinasa Mini-C5A sensor.

2. Technical Specifications

The following table details the technical parameters of the Mini-C5A sensor:

ParametersMeasurement RangeAccuracyResolution
Wind speed0 ~ 45m/s±(0.5+0.02V)m/s0.01m/s
Wind direction0 ~ 360°±3°1°
Air temperature-40 ~ 80°C±0.3°C0.1°C
Air humidity0 ~ 100%RH±5%RH0.1%RH
Atmospheric pressure300 ~ 1100hPa±0.5hPa (25°C)0.1hPa
Power supplyDC9-30V
Digital outputRS485 (default) or RS232
Communication baud rate9600
Communication protocolMODBUS communication protocol
Shell materialEngineering plastics (ABS white material, resistant to sunshine and rain)
Operating temperature-20°C ~ 80°C
Storage temperature-50°C ~ 80°C
Working humidity0-100%
Appearance size/weightφ80 X 100mm / 0.3Kg
Class of protectionIP65
Global power consumption0.12W
Mini-C2A Sensor Specifications
Figure 2: Mini-C2A model with basic specifications (similar to Mini-C5A).
Sensor Components
Figure 3: Internal components and structure of the sensor.

3. Setup and Installation

3.1. Installation Precautions

  • Regularly check to ensure the sensor is not interfered with by other operating equipment that may not comply with common standards (e.g., radio/radar transmitters, ship engines).
  • Do not install the sensor in a flat plane with any radar scanning device; maintain a distance of at least 2 meters.
  • It is recommended to maintain a distance from surrounding radio receiving antennas.
  • Use only the cables recommended by Veinasa.
  • If the cable is cut or improperly connected, or if the shielded cable is not properly connected, follow the installation guide to connect cables and avoid ground loops.
  • Ensure a continuous power supply when the equipment is running.
  • Avoid surrounding buildings such as trees, telephone poles, or tall structures, which can affect the accuracy of the ultrasonic anemometer.

3.2. World Meteorological Organization (WMO) Advice

  • Installation Standards: For open areas, install more than 10 meters above the ground. An open area is defined as a weather instrument above 10 meters above the height of any obstacle.
  • Building Installation: If installed on a building, the theoretical installation height should be 1.5 times the height of the building.
  • Mast/Boom Mounting: If mounted on a boom on a mast or tower, the boom's length must be at least twice the minimum diameter or diagonal of the tower. The boom should be installed on the prevailing wind side.

3.3. Installation Method

The general equipment is installed on a vertical installation tube to ensure measurement on the same horizontal plane.

  • Alignment: The detector should point to the north before fixing it. Use a standard north pointer to determine the geographical North Pole direction.
  • Cable Installation: Install the cable through the installation tube. Ensure appropriate stress relief on the cable. Connect the plug to the device by turning and gently pushing it in. Once connected, turn the outer sleeve clockwise to lock the plug.
  • Mounting: The equipment can be fixed on the installation pipe using screws. Ensure the equipment is installed in an open area to prevent obstructions to airflow or flocculation. Do not install near radar or radio transmitters.
Flange Mounting Plate
Figure 4: Flange mounting plate for secure installation.
Sensor Details with Flange
Figure 5: Detailed view of the sensor with the flange mount.

3.4. Wiring Method

The sensor features a 4-core aviation plug at the bottom. The pin definitions are as follows:

Line ColorOutput Signal / Communication Type
RedPower supply (+)
BlackGND
YellowRS485+ / A+ / TX
GreenRS485- / B- / RX

Note: The wiring label on the communication cable shall prevail for specific connections.

  • If using a collector produced by Veinasa, directly use the sensor cable to connect the sensor to the corresponding interface on the collector.
  • If the transmitter is purchased separately, ensure the wire sequence matches the transmitter's requirements.
Aircraft Socket Connection
Figure 6: Aircraft socket connection point on the sensor.
Sensor with Cable Connected
Figure 7: Sensor with communication cable connected.
Sensor Cable Connection Detail
Figure 8: Close-up of the sensor's cable connection and securing mechanism.

3.5. Dimensions

Sensor Dimensions Diagram
Figure 9: Diagram showing the dimensions of the Mini-C5A sensor (φ80 x 100mm).

4. Operating Instructions: MODBUS Communication Protocol

The Mini-C5A sensor communicates using the MODBUS protocol. The communication parameters are:

  • Baud rate: 9600
  • Data bit: 8 bits
  • Check bit: No check bit

The interval between two communications must be at least 1000ms.

4.1. Write Device Address

To write the device address, send a 5-byte command:

  • Send: 00 10 Address CRC (5 bytes)
  • Return: 00 10 CRC (4 bytes)

Note: The address bit of the read and write address command must be 00. The Address value is 1 byte, ranging from 0 to 255.

Example:

  • To send address 01: 00 10 01 BD C0
  • Returns: 00 10 00 7C

4.2. Read Device Address

To read the device address, send a 4-byte command:

  • Send: 00 20 CRC (4 bytes)
  • Return: 00 20 Address CRC (5 bytes)

Note: Address is 1 byte and ranges from 0 to 255.

Example:

  • To send: 00 20 00 68
  • Returns: 00 20 01 A9 C0

4.3. Read Real-time Data

To read real-time data (e.g., for the first 10 registers), assuming the device address is 0X01 (valid range 0-255, 0 for broadcast address):

  • Send: 01 03 00 00 00 05 85 C9
  • Return: 01 03 0A 00 30 00 B0 00 FA 02 8A 27 AC 22 B7

Data Analysis Example:

  • 0A: Number of bytes in the data field (10 bytes).
  • 00 30: Wind speed data (hexadecimal 30 = decimal 48). With a resolution of 0.01, this is 0.48 m/s.
  • 00 B0: Wind direction data (hexadecimal B0 = decimal 176). With a resolution of 1, this is 176 degrees clockwise north.
  • 00 FA: Temperature data (hexadecimal FA = decimal 250). With a resolution of 0.1, this is 25.0°C. Negative temperatures are expressed as a hexadecimal complement. For example, FF 65 (hex) = -155 (decimal), which with 0.1 resolution is -15.5°C.
  • 02 8A: Humidity data (hexadecimal 28A = decimal 650). With a resolution of 0.1, this is 65.0%RH.
  • 27 AC: Air pressure data (hexadecimal 27AC = decimal 10156). With a resolution of 0.1, this is 1015.6 hPa.

4.4. CRC 16 Check Code Calculation

  1. Preset a 16-bit register as hexadecimal FFFF (all 1s); this is the CRC register.
  2. XOR the first 8-bit binary data (first byte of communication frame) with the low 8-bit of the 16-bit CRC register, or put the result in the CRC register.
  3. Move the content of the CRC register one bit to the right (towards the low), fill the highest bit with 0, and check the removed bit after the right shift.
  4. If the removed bit is 0, repeat step 3. If the removed bit is 1, XOR the CRC register with polynomial A001 (1010 0000 0000 0001).
  5. Repeat steps 3 and 4 eight times to process the entire 8-bit data.
  6. Repeat steps 2 to 5 for the next byte of the communication frame.
  7. After calculating all bytes, exchange the high and low bytes of the obtained 16-bit CRC register.
  8. The final CRC register content is the CRC16 code (note that the CRC code obtained is in low-front, high-back order).

5. Maintenance

The Veinasa Mini-C5A sensor is designed with no moving parts, which significantly reduces the need for complex routine maintenance. It does not require on-site maintenance or calibration under normal operating conditions.

  • To ensure optimal performance, periodically check the installation area to confirm no new obstructions or sources of interference (e.g., new radio transmitters, tall structures) have appeared that could affect the sensor's readings.
  • Keep the sensor clean from excessive dust or debris, especially around the measurement areas, though its design is resistant to sunshine and rain.

6. Troubleshooting

If you encounter any problems with the equipment, please refer to the following general advice:

  • Communication Issues: Verify all wiring connections are secure and correct according to the wiring diagram. Ensure the power supply is stable and within the specified voltage range (DC9-30V). Check MODBUS communication parameters (baud rate, data bits, check bit) are correctly configured on your receiving device.
  • Inaccurate Readings: Review the installation site for any new obstructions (trees, buildings, etc.) that might be affecting airflow or sensor exposure. Confirm the sensor is correctly aligned to the north as per installation instructions.
  • General Malfunctions: If the device is not functioning as expected after checking basic connections and environment, it is recommended to contact Veinasa customer support for assistance.

Important Note: Opening the device or damaging the security seal will void the quality assurance and accuracy provided by Veinasa. Any equipment requiring return for repair should be carefully packed in its original packaging with a detailed description of the failure.

7. User Tips

  • Technical Documentation: For specific technical queries or detailed documentation beyond this manual, it is highly recommended to contact Veinasa customer support. They are responsive and can provide additional technical information.
  • Model Verification: Before installation and operation, double-check that you have the correct model (e.g., RS232 or RS485) and ensure your data logger or receiver is compatible with the chosen output interface.
  • Modbus Communication Test: After initial setup, perform a basic Modbus communication test to confirm data transmission is working correctly. This can help identify wiring or configuration issues early.
  • Environmental Considerations: If using the sensor in specialized environments like marine applications (e.g., on a sailboat), consider additional protective measures or specific mounting considerations for extreme conditions.

8. Warranty and Support

This material is subject to copyright protection, with all copyrights retained by Veinasa. Any logos and/or product names are trademarks of Veinasa. Reproduction, transfer, distribution, or storage of information contained in this material in any form without the prior written consent of Veinasa is strictly prohibited.

If you have any questions or require support, please contact Veinasa using the information below. Our team is available to assist with problem analysis and solutions.

Contact Information:

  • Company: Mianyang Xiangshu Electronic Technology Co., LTD
  • Phone: 86-0816-2712180
  • Fax: 86-0816-2712180
  • E-mail: info@veinasa.com
  • WhatsApp/Skype/Wechat: 86-18161001208
  • Address: Innovation Center, Mianyang Science and Technology City New District, Mianyang City, Sichuan Province

For further details, you may also refer to the official user manual PDF available at: Veinasa Mini-C5A User Manual (PDF)

Appendix: Wind Speed Scale

The following table provides a general wind speed scale for reference:

LevelNameLand Features of Ground ObjectsWind Speed (m/s)
0CalmQuiet, smoke straight up0 ~ 0.2
1Light airSmoke indicates the direction of the wind, and leaves shake slightly0.3 ~ 1.5
2Light breezeI felt the wind on my face and the leaves moved1.6 ~ 3.3
3Gentle breezeLeaves and twigs waved, flags spread, tall grass waved3.4 ~ 5.4
4Moderate breezeIt blows dust and paper from the ground, shakes tree branches, and undulates tall grass5.5 ~ 7.9
5Fresh breezeThe small leafy trees swayed, the inland water surface had small waves, and the tall grass waves undulated markedly8.0 ~ 10.7
6Strong breezeBig branches shake, power lines whirr, umbrellas are difficult to hold, tall grass sometimes falls to the ground10.8 ~ 13.8
7Moderate galeThe whole tree shakes, the branches bend down, and it feels inconvenient to walk against the wind13.9 ~ 17.1
8Fresh galeCan break small branches, people into the wind resistance is great17.2 ~ 20.7
9Strong galeGrass huts were damaged, roof tiles were lifted and large branches could be broken.20.8 ~ 24.4
10Whole galeTrees can be blown down and general buildings damaged24.5 ~ 28.4
11StormLarge trees can be blown down and general buildings severely damaged28.5 ~ 32.6
12HurricaneLand is rare, and its destructive power is great>32.6

Ask a question about this manual