JIKONG JK-BD4A24S-4P

Contents

JIKONG Smart BMS BD4A24S4P User Manual

Lithium Battery Active Balancing Protection Board

1. Product Overview

The JIKONG Smart BMS (Battery Management System) is an intelligent protection board designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge/over-discharge protection, overcurrent protection, over-temperature protection, coulomb metering, Bluetooth communication, and optional GPS remote functionality.

This BMS is compatible with LiFePO4, ternary lithium, and LTO battery types. It utilizes energy transfer active balancing technology with independent intellectual property rights, achieving a continuous 0.4A balance current. This high-current active equalization ensures battery consistency, improves battery range, and extends battery life.

The protection board is managed via a mobile APP available for Android and iOS. The APP connects to the BMS via Bluetooth, allowing real-time monitoring of battery status, modification of working parameters, and control of charge/discharge switches. Its compact size and comprehensive functions make it suitable for various applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.

JIKONG Smart BMS BD4A24S4P product image with key features

Figure 1: JIKONG Smart BMS BD4A24S4P with key features.

2. Functional Characteristics

  • LED Bluetooth status indicator
  • APP Bluetooth remote operation
  • Battery capacity calculation
  • High precision voltage acquisition (±3mV)
  • High precision current acquisition
  • Support information screen display
  • Accurate time logging
  • Support RS485 (Optional)
  • Support CAN (Optional)
  • Support parallel function (Optional)
  • Support alarm function (Optional)
  • Support heating function (Optional)
  • Support GPS communication
  • Charge overcurrent protection
  • Charge overvoltage protection
  • Charge over temperature protection
  • Low temperature protection during charge
  • Discharge overcurrent protection
  • Discharge undervoltage protection
  • Discharge over temperature protection
  • Short circuit protection
Diagram showing six security protections: Overcharge, Short circuit, Overcurrent, Cable drop/poor contact, Overtemp.

Figure 2: Six major security protections provided by the BMS.

3. Setup Instructions

3.1. Package Contents

Package contents: BMS, NTC (40cm), Switch (50cm), Wires (70cm), Pack box, Operate manual.

Figure 3: Contents included in the JIKONG Smart BMS package.

The package typically includes the JIKONG Smart BMS unit, a 40cm NTC temperature sensor, a 50cm active switch, 70cm balance wires, and an operation manual (PDF).

3.2. Hardware Connection

The JIKONG Smart BMS BD4A24S-4P series protection board is suitable for 7-24 series lithium battery packs. The wiring method varies depending on the number of cells in the battery pack. Always ensure correct polarity and secure connections.

  1. Connect the protection board and battery pack according to the wiring diagram. Ensure that the last power cord (B+) is connected to the main positive pole of the battery pack.
  2. The total voltage of the battery pack must be greater than 20V (for default BMS) or 10V (for 4S BMS) before initial startup.
  3. Ensure that the balance cable is properly connected and that the P- and B- terminals are correctly connected.
  4. Verify that the protection board is securely fixed to the battery pack.
Wiring diagram for battery pack connection showing B+, P-, B-, sampling cable, motor/load, and charger connections.

Figure 4: General wiring diagram for the JIKONG Smart BMS.

3.2V LiFePO4 battery assembly instructions showing series and parallel connection diagrams.

Figure 5: Battery assembly instructions for series and parallel connections.

Connection Method diagrams for various string numbers.

Figure 6: Connection diagrams for various battery string configurations (e.g., 7S, 8S, 10S, 13S, 16S, 20S, 21S, 22S, 24S).

Additional Connection Method diagrams for various string numbers.

Figure 7: Further connection diagrams for various battery string configurations.

3.3. Device Activation

The protection board does not have a power-on control switch. It is designed for charging activation mode. After the battery assembly is complete, connect the charger (charger voltage should be 2V higher than battery voltage) to activate the BMS.

Alternatively, the BMS can be activated using a display activation button or an additional switch. If you have a display screen or button, insert the cable into the display interface and press the button to activate.

3.4. APP Installation

The mobile APP is essential for monitoring and configuring the BMS. You can download the APP by searching for "JIKONG BMS" or "JK BMS" in your device's app store.

  • iOS: Search for "JIKONG BMS" in the APP STORE.
  • Android: Search for "JK BMS" in the Google STORE. (Android Version 7 or higher is required).
QR code for JIKONG BMS mobile APP.

Figure 8: Scan this QR code to download the JIKONG BMS mobile APP.

For detailed instructions and BMS protocol, refer to the official GitHub repositories:

4. Operating the BMS

4.1. APP Connection and Initial Setup

  1. Turn on GPS and Bluetooth on your mobile phone.
  2. Open the JIKONG BMS APP. Click on the top left corner of the APP to search for devices.
  3. Select your device from the list and click to connect. The default password is 1234.
  4. For the first startup, parameters need to be set. The default parameter setting password is 123456. Set the number of units (battery strings) and battery type (Li-ion, LiFePo4, LTO) according to your battery pack.
  5. After setting the parameters, go back to the real-time status page to check the battery status. Ensure no error messages are prompted and normal operation is indicated. Blue indicates the highest cell voltage, and red indicates the lowest cell voltage.
Smart Bluetooth APP interface showing real-time data monitoring, parameter modification, and balance switch control.

Figure 9: Smart Bluetooth APP interface for monitoring and control.

Video 1: Demonstration of JIKONG Active Balance BMS features, including 24-hour detection, smart management via app, compatibility with different string numbers, and 6 major protections.

4.2. Active Equalization

The BMS employs active equalization to transfer energy from high-voltage cells to low-voltage cells, ensuring cell voltage consistency. The default balance current is 0.4A. You can adjust the balance current via the APP based on your battery capacity, ensuring it does not exceed 0.2C of the battery capacity. If not needed, the balancing function can be turned off in the APP's BMS control page.

4.3. GPS and Display Interface

The BMS has reserved ports for optional GPS modules and display screens. Users can connect these accessories to meet their specific needs for battery location tracking or real-time battery information display.

4.4. Heating Function (Optional)

If your BMS model includes the heating function (indicated by "Heat" in the model name), it can heat the battery at low temperatures to prevent performance degradation. The designed heating current is 10A. This function can be switched on/off via the APP. It is recommended to install a temperature control switch (45°C to 65°C, normally closed) in series with the heating circuit for secondary protection.

The heating function is activated when the battery temperature is below the low-temperature protection threshold for charging. Heating can be achieved via an external heating film or a smart charger. The green cable connects to the heating film, while red and black cables connect to the charger. Maximum heating power is 3A, and maximum heating voltage is 100V.

4.5. Communication Function (Optional)

The BMS supports optional CAN and RS485 communication functions. Users can select these based on their requirements and configure the address and communication protocol via the APP. Refer to the Jikong Protection Board Communication Protocol document for specific details.

5. Maintenance

5.1. Smart Energy Working Modes

The BMS features different working modes to optimize battery life and energy consumption:

  • Storage Mode: In transportation, storage, or wireless transmission off mode, the BMS consumes no battery pack current.
  • Normal Working Mode: When the charger is inserted in storage or off mode, the BMS immediately returns to normal working mode, and all protection, equalization, and communication functions are restored.
  • Standby Mode: If the battery pack is static (no charge/discharge current, no equilibrium current) for more than a set time (1-30 days, configurable), the BMS enters standby.
  • Shutdown: To prevent long-term power waste and battery damage, the BMS automatically shuts down when a cell falls below the shutdown voltage.
Smart energy working mode switching diagram (Storage, Normal, Standby, Shutdown).

Figure 10: Smart energy working mode switching diagram.

5.2. Intelligent Sleep Function

The BMS includes an intelligent sleep function to reduce its self-consumption. When the BMS is in standby (charging and discharging current less than 1A for 26 consecutive hours), it will shut down. To reactivate, press the activation button or connect the charger.

5.3. General Care

Regularly check all connections for tightness and corrosion. Keep the BMS clean and free from dust and moisture. Avoid exposing the BMS to extreme temperatures or direct sunlight for prolonged periods.

6. Troubleshooting

6.1. Common Issues and Solutions

  • BMS Does Not Turn On:
    1. Ensure the last B+ line of the cable is connected to the positive pole of the battery.
    2. Start up after charging, ensuring the charger voltage is greater than 4V above the battery pack voltage.
    3. Check if the charger has voltage output.
  • Inaccurate Voltage Readings:
    1. Measure the actual total voltage of the battery pack with a multimeter.
    2. Enter the actual total voltage in the "voltage calibration" setting on the APP's parameter page.
  • Inaccurate Current Readings:
    1. Ensure both B- and P- terminals of the protection board (two 7AWG wires) are connected in parallel; otherwise, it will lead to current error.
    2. Measure the actual current of the battery pack with a clamp meter.
    3. Enter the actual current into the "current calibration" setting on the APP's parameter page. Higher actual current leads to higher calibration accuracy.
  • Inaccurate Capacity Readings:
    1. The initial capacity estimated when the protection board is first powered on may be inaccurate.
    2. Calibrate the capacity by fully discharging the battery pack to the cut-off voltage and then fully charging it without interruption.
  • Inconsistent Designed String Number with Actual String Number:
    1. Check if the "unit quantity" in the APP's parameter settings is set correctly.
    2. If there is no voltage in two or more strings in the middle of the pack, check whether the acquisition cable has fallen off.

6.2. Protection Features and Recovery

The BMS is equipped with various protection mechanisms to safeguard your battery pack:

  • Charge Overvoltage Protection: If any cell voltage exceeds the set overvoltage protection, charging will stop. It resumes when all cell voltages drop below the recovery voltage.
  • Discharge Undervoltage Protection: If any cell voltage drops below the set undervoltage protection, discharging will stop. It resumes when all cell voltages rise above the recovery voltage. The BMS will automatically shut down if any cell voltage falls below the automatic shutdown voltage.
  • Charge Overcurrent Protection: If charging current exceeds the set limit for a specified delay, charging stops. It resumes after the overcurrent release time.
  • Discharge Overcurrent Protection: If discharging current exceeds the set limit for a specified delay, discharging stops. It resumes after the overcurrent release time. (Note: Maximum continuous discharge current cannot exceed 40A).
  • Over Temperature Protection: If the BMS detects an over-temperature condition during charge or discharge, the respective operation will stop. It resumes when the temperature returns to a safe level.
  • Low Temperature Protection: If the BMS detects a low-temperature condition during charge, charging will stop. It resumes when the temperature returns to a safe level.
  • Short Circuit Protection: The BMS has a standard short-circuit protection. If triggered, it will stop operation and resume after a set recovery time. If a short circuit occurs during initial connection of a charger or load, increasing the short circuit protection delay in the APP may resolve it.
  • Emergency Switch: In case of critical issues (over-temperature, over-discharge, over-charge, cell drop), activating the emergency switch in the APP will allow 30 minutes of charge/discharge operation, even if cell voltages reach the automatic shutdown level, to prevent dangerous situations.

7. Specifications

7.1. Basic Parameters

Parameter Value Unit
Supply Voltage20-100V
Operating Power Consumption<800mW
Operating Temperature-30-70°C
Maximum Number of Collection Strings24Strings
Maximum Balancing Current0.4A
Maximum Charging Current40A
Maximum Discharge Current40A
Maximum Instantaneous Current80A
Maximum Internal Loop Resistance2.8mΩ
Protective Plate Size116*103*17.6mm
Finished Weight205g

7.2. Default Parameters (Example for Li-ion)

Parameter Li-ion Default Unit
Balancing Initial Voltage3V
Maximum Balancing Current0.4A
Unit Overcharge Voltage4.2V
Single Overcharge Protection Recovery4.18V
Monomer Undervoltage Protection2.82V
Single Undervoltage Protection Recovery2.85V
Automatic Shutdown Voltage2.8V
SOC-0% Voltage2.9V
SOC-100% Voltage4.18V
Trigger Balancing Differential Pressure0.01V
Charging Overcurrent Protection Delay30S
Charge Overcurrent Protection Release Time60S
Discharge Overcurrent Protection Delay300S
Discharge Overcurrent Protection Release Time60S
Short-circuit Protection Delay5uS
Charging Overtemperature Protection70°C
Charging Overtemperature Recovery60°C
Discharge Overtemperature Protection70°C
Discharge Overtemperature Recovery60°C
Charging Low Temperature Protection-20°C
Charging Low Temperature Recovery-10°C
MOS Overtemperature Protection100°C
MOS Overtemperature Recovery80°C
Device Address0/

7.3. Product Dimensions

Diagram showing the dimensions of the JIKONG Smart BMS BD4A24S-4P: 116mm x 103mm x 17.6mm.

Figure 11: Dimensions of the JIKONG Smart BMS BD4A24S-4P.

8. User Tips

  • Always double-check all wiring connections before powering on the BMS to prevent damage.
  • For optimal performance and longevity, ensure your battery pack is well-balanced. The active balancing feature of this BMS helps maintain cell consistency.
  • Regularly monitor your battery's status via the mobile APP to catch any potential issues early.
  • If using the heating function in cold climates, consider adding a secondary temperature switch for enhanced safety.
  • When calibrating voltage or current, use accurate measurement tools (multimeter, clamp meter) for precise readings.

9. Support and Further Information

For detailed technical specifications, wiring diagrams for specific configurations, and advanced parameter settings, please refer to the complete user manual PDF provided by JIKONG. This document contains comprehensive information on all aspects of the BMS.

PDF User Manual: JIKONG Smart BMS User Manual (PDF)

For any further assistance or inquiries, please contact JIKONG customer support, providing your product model (JK-BD4A24S-4P) and any relevant details.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.