1. Product Overview
The KYORITSU 1109S and 1110 are high-quality analog multimeters designed for accurate measurement of various electrical characteristics. They are built with durability and user safety in mind, featuring robust designs and clear, easy-to-read scales.


1.1 Key Features
Model 1109S
- Mirrored scale for easy and accurate reading.
- Output terminal to cut off DC component when measuring AC voltage.
- Safety designed input terminals and test leads.
Model 1110
- High sensitivity DC20kΩ/V.
- 1m drop-proof heavy duty design.
- Can measure line voltage up to AC 600V (Voltage to ground MAX AC 300V).
- Protected by 600V ceramic fuse against accidental overload.
- Continuity buzzer, battery check, LED check function.
- Skeleton type robust and clear case with carrying handle furnished as standard accessory.
2. Safety Information
Always read and understand all safety warnings and operating instructions before using the multimeter. Failure to do so may result in injury or damage to the instrument.
- Ensure the correct function and range are selected before making any measurements.
- Do not exceed the maximum input values for any range.
- Always inspect test leads for damage before use.
- When measuring current, ensure the meter is connected in series with the load.
- When measuring voltage, connect the meter in parallel with the circuit.
- Replace batteries when the low battery indicator appears to ensure accurate readings.
- Do not use the multimeter in wet environments or in the presence of explosive gases or dust.
3. Setup
3.1 Unpacking and Inspection
Carefully unpack the multimeter and all accessories. Verify that all items listed in the specifications are present and undamaged.

3.2 Battery Installation
Refer to the specifications for the correct battery type (R6 (AA) (1.5V) x 2 and 6F22 (9V) x 1 for 1109S; R6 (AA) (1.5V) x 2 for 1110). Open the battery compartment, insert the batteries with correct polarity, and close the compartment securely.
3.3 Connecting Test Leads
Insert the red test lead into the positive (+) input jack and the black test lead into the negative (-) or common (COM) input jack. Ensure a secure connection.
4. Operating Instructions
The KYORITSU analog multimeters are designed for measuring DC Voltage, AC Voltage, DC Current, and Resistance. Some models also include continuity, battery, and LED check functions.

4.1 Measuring DC Voltage (DC V)
- Set the rotary switch to the desired DC V range.
- Connect the red test lead to the positive side of the circuit and the black test lead to the negative side.
- Read the voltage value on the appropriate scale.
4.2 Measuring AC Voltage (AC V)
- Set the rotary switch to the desired AC V range.
- Connect the test leads across the circuit to be measured.
- Read the voltage value on the appropriate scale.
4.3 Measuring DC Current (DC A)
- Set the rotary switch to the desired DC A range.
- Connect the multimeter in series with the circuit.
- Read the current value on the appropriate scale.
4.4 Measuring Resistance (Ω)
- Set the rotary switch to the desired Ω range.
- Short the test leads together and adjust the "0Ω ADJ" knob to set the pointer to zero.
- Connect the test leads across the component to be measured.
- Read the resistance value on the appropriate scale.
4.5 Continuity Check (Model 1110)
- Set the rotary switch to the continuity buzzer position.
- Connect the test leads across the circuit or component.
- A buzzer will sound if the resistance is below 100Ω.
4.6 Battery Test (Model 1110)
- Set the rotary switch to the BATT. TEST position.
- Connect the test leads to the battery terminals.
- Read the battery voltage on the appropriate scale.
4.7 LED Test (Model 1110)
- Set the rotary switch to the LED TEST position.
- Connect the test leads to the LED.
- The LED should light up if it is functional.
5. Maintenance
5.1 Cleaning
Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.
5.2 Battery Replacement
When the meter's readings become unstable or the low battery indicator (if present) illuminates, replace the batteries. Ensure the meter is off and test leads are disconnected before opening the battery compartment.
5.3 Fuse Replacement (Model 1110)
The Model 1110 is protected by a 600V ceramic fuse. If the current measurement function stops working, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Always replace with an identical fuse.
6. Troubleshooting
- No reading/Incorrect reading:
- Check battery level and replace if necessary.
- Ensure test leads are properly connected and not damaged.
- Verify the correct function and range are selected.
- For resistance measurements, ensure the "0Ω ADJ" is calibrated.
- No continuity buzzer (Model 1110):
- Check if the circuit resistance is above 100Ω.
- Ensure the battery is not depleted.
- Meter not turning on:
- Check battery installation and charge.
7. Specifications
7.1 Model 1109S Specifications

| Measurement | Range/Accuracy |
|---|---|
| DC V | 0.1/0.5/2.5/10/50/250/1000V ±3% of FS |
| AC V | 10/50/250/1000V (9kΩ/V) ±4% of FS |
| DC A | 50µA/2.5/25/250mA ±3% of FS |
| Ω | 2/20kΩ/2/20MΩ ±3% of scale length |
| Decibel | -10 - +62dB |
| hFE | 0 - 1000 (Ω x 10) ±3% of scale length |
| Power source | R6 (AA) (1.5V) × 2, 6F22 (9V) × 1 |
| Dimension | 150(L) × 100(W) × 47(D)mm |
| Weight | Approx. 330g |
| Accessories | 7066A (Test leads), 8901(Fuse[0.5A/250V]) × 1 (included), 1 (spare), R6 (AA) × 2, 6F22 × 1, Instruction Manual |
| Optional Accessories | 9168 (Carrying Case) |
7.2 Model 1110 Specifications

| Measurement | Range/Accuracy |
|---|---|
| DC V | 3/12/30/120/300/600V (20kΩ/V) ±3% of FS |
| AC V | 12V (9kΩ/V) ±4% of FS, 30/120/300/600V (9kΩ/V) ±3% of FS |
| DC A | 60µA/30/300mA ±3% of FS |
| Ω | 3/30/300kΩ ±3% of scale length |
| Continuity buzzer | Buzzer sounds below 100Ω |
| Battery Test | 1.5V (0.7 - 2V) ±3% of FS (10Ω load) |
| Temperature | Possible with the temperature probe 7060 (discontinued). |
| LED | Approx. 10mA at 0Ω (at 3V of battery voltage) |
| Applicable standards | IEC 61010-1, CAT III 300V Pollution Degree 2, CAT II 600V Pollution Degree 2, IEC 61010-2-031 |
| Power source | R6 (AA) (1.5V) × 2 |
| Dimension | 140(L) × 94(W) × 39(D) mm |
| Weight | Approx. 280g |
| Accessories | 7066A (Test leads), 8923(Fuse[0.5A/600V]) × 1 (included), 1 (spare), 9103 (Carrying case), R6 (AA) × 2, Instruction Manual |
8. User Tips
- For precise resistance measurements, always perform the "0Ω ADJ" calibration before testing.
- When measuring AC voltage, remember that the output terminal on the 1109S can cut off the DC component, which is useful for specific applications.
- Utilize the drop-proof design of the 1110 model for fieldwork, but always handle with care to prolong its lifespan.
9. Warranty and Support
For warranty information and technical support, please refer to the warranty card included with your product or contact KYORITSU customer service. Keep your purchase receipt as proof of purchase.
10. About KYORITSU
KYORITSU Electrical Instruments Works has a rich history dating back to 1940, when it was founded in Tokyo. The company has been committed to producing high-quality portable measuring instruments, establishing a solid reputation in Japan and globally. They continuously innovate, offering products with features like Bluetooth connectivity for IoT applications, and maintain stringent quality control through automated inspection systems.