1. Introduction
The Yaxun Bench Source 1501 AD is a versatile analog DC power supply designed specifically for mobile phone, smartphone, tablet, and general electronics repair. It features both analog and digital displays for precise voltage and current monitoring, along with a unique radio-frequency (RF) test function. This manual provides essential information for the safe and effective use of your device.
2. Safety Information
- Always ensure the power supply is connected to a grounded 110V AC outlet.
- Do not operate the device in wet or damp conditions.
- Avoid touching live terminals or internal components when the unit is powered on.
- Ensure proper ventilation around the unit to prevent overheating.
- Disconnect power before making any connections or disconnections to the output terminals.
- Do not attempt to open or repair the unit yourself. Refer all servicing to qualified personnel.
- Verify the voltage and current settings before connecting any device to prevent damage.
3. Product Overview
The Yaxun Bench Source 1501 AD is equipped with a user-friendly front panel for easy operation and monitoring.

Front Panel Components:
- Analog Voltmeter (V): Displays the output voltage.
- Analog Ammeter (A): Displays the output current.
- Digital Voltage Display (V): Provides a precise digital readout of the output voltage.
- RF Signal Strength Indicator: Displays the strength of radio frequency waves, useful for testing mobile devices (labeled 40, 35, 25, 20, RF).
- VOLTAGE Knob: Used to adjust the output voltage.
- Function Toggle Switch: Selects between power output and voltmeter functions.
- Power Switch: Turns the unit ON or OFF.
- Output Terminals (Red and Black): Main terminals for connecting devices.
- Auxiliary Jacks: Additional input/output connections for specific testing needs.
4. Setup
- Unpacking: Carefully remove the power supply from its packaging. Inspect for any signs of damage.
- Placement: Place the unit on a stable, level surface with adequate ventilation. Ensure no objects block the ventilation openings.
- Power Connection: Connect the power cord to the AC input on the rear of the unit and then to a standard 110V AC grounded wall outlet.
- Initial Check: Before connecting any device, ensure the VOLTAGE knob is set to its minimum position.
5. Operating Instructions
5.1 Basic Operation
- Power On: Flip the Power Switch to the 'ON' position. The digital voltage display and analog meters should illuminate.
- Adjusting Voltage: Slowly turn the VOLTAGE knob clockwise to increase the output voltage. Observe both the analog voltmeter and the digital display for the desired voltage.
- Connecting a Device: With the power supply OFF, connect the positive (+) lead of your device to the red output terminal and the negative (-) lead to the black output terminal.
- Applying Power: Once the device is connected and the desired voltage is set (while the power supply is OFF), turn the Power Switch ON. Monitor the analog ammeter to observe the current draw of your device.
- Power Off: Before disconnecting your device, turn the Power Switch to the 'OFF' position.
5.2 RF Test Function
The RF test function allows for monitoring radio frequency waves, which is particularly useful when working with mobile phones. To use this feature:
- Ensure the power supply is on and a mobile device is connected and powered.
- Observe the RF Signal Strength Indicator. When the mobile device transmits or receives, the indicator will show varying levels (20, 25, 35, 40, RF) corresponding to the signal strength.
- This can help diagnose issues related to a device's RF module or antenna.
6. Maintenance
- Cleaning: Regularly wipe the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the unit is unplugged before cleaning.
- Ventilation: Keep the ventilation openings clear of dust and debris to ensure proper airflow.
- Storage: When not in use, store the power supply in a cool, dry place, away from direct sunlight and extreme temperatures.
- Cable Inspection: Periodically check power cords and output leads for any signs of wear or damage. Replace if necessary.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not power on | No power from outlet; Power cord loose/damaged; Internal fuse blown | Check outlet with another device; Ensure power cord is securely connected; Contact service for fuse replacement. |
| No voltage output | Voltage knob at minimum; Function switch incorrect; Overload protection activated | Increase voltage with knob; Ensure function switch is set to power output; Disconnect load, power cycle unit. |
| Incorrect voltage/current readings | Faulty connection; Unit malfunction | Check all connections; Compare readings with a multimeter; Contact service if discrepancy persists. |
| RF indicator not responding | Mobile device not transmitting/receiving; RF sensor issue | Ensure mobile device is active (e.g., making a call); Contact service if issue persists. |
8. Specifications
| Feature | Specification |
|---|---|
| Input Voltage | 110V AC |
| Display Type | Analog (Voltage, Amperage), Digital (Voltage) |
| RF Test Range | 20/25/35/40 |
| Operating Temperature | -10 to +40 °C |
| Storage Temperature | -10 to +40 °C |
| Temperature Coefficient | 300PPM/°C |
| Operating Humidity | <90% |
| Storage Humidity | <80% |
| Recovery Time | = 100uS |
| Source Type | Asymmetric |
| Dimensions (LxWxH) | 21 x 14 x 20.5 cm |
| Weight | 1.9 Kg |
9. User Tips
- Always double-check the voltage setting on both the analog and digital displays before connecting a sensitive device.
- Start with the lowest possible voltage and gradually increase it to the required level for the device you are testing.
- Observe the ammeter for unusual current draws, which can indicate a short circuit or other fault in the connected device.
- Use high-quality test leads with appropriate connectors to ensure stable and reliable connections.
- For mobile phone repair, be aware of the typical operating voltages and current consumption of different phone models.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided at the point of purchase or contact your vendor. Keep your purchase receipt as proof of purchase.