SHALUO SX460 AVR

Contents

SHALUO SX460 AVR Automatic Voltage Regulator User Manual

Model: SX460 AVR

1. Introduction

The SHALUO SX460 is a high-quality Automatic Voltage Regulator (AVR) designed for brushless generators. It provides stable voltage output, ensuring reliable performance for your generator system. This manual provides detailed instructions for installation, operation, maintenance, and specifications of the SX460 AVR.

Video 1: SHALUO SX460 AVR Product Overview

2. Specifications

FeatureSpecification
Model NumberSHALUO SX460 AVR
Brand NameSHALUO
Use ForBrushless Generator
Power For100KW
OriginMainland China
Is it electrifiedNo
High-concerned chemicalNone
Is customizedYes

Detailed Electrical Specifications:

  • Sensing Input:
    • Voltage: 95~132VAC or 190~264VAC, 1 phase, jumper selectable
    • Frequency: 50/60 Hz, selectable
  • Output:
    • Voltage: Max. 90 VDC @ 207 VAC
    • Current: Continuous 4A, Intermittent 10A for 10 sec.
    • Resistance: Min. 15 ohm
  • Voltage Regulation: <+ 1.5% (with 4% engine governing)
  • Voltage Build-up: Residual voltage at AVR terminal > 5 VAC
  • Thermal Drift: 0.05% per °C change in AVR ambient
  • External Volts Adjustment: ±7% with 1K ohm 1 watt trimmer
  • Unit Power Dissipation: Max. 10 watt
  • Under Frequency Protection (UFRO):
    • Set point: 95% Hz
    • Slope: 170% down to 30 Hz
  • Soft Start Ramp Time: 2 sec.
  • Dimensions: 135mm (L) x 100mm (W) x 49mm (H)
  • Weight: 243g ± 2%
Back view of SHALUO SX460 AVR with dimensions 80mm width and 115mm height

Figure 1: SHALUO SX460 AVR Back View with Dimensions

3. Setup and Installation

Proper installation is crucial for the safe and effective operation of the SHALUO SX460 AVR. Refer to the wiring diagrams and instructions below carefully.

Wiring Instructions:

  1. Connect F1 and F2 terminals to the DC output port of the exciter.
  2. Connect the sensing input port at terminals 7 and 8. The factory default setup is for 220V sensing. If 110V sensing is required, connect terminals 3 and 4.
  3. For external voltage regulation, refer to Figure 4 in the diagram below.
  4. For 50Hz operation, connect a jumper from the COM terminal to the 50Hz terminal.

Note: Install a 5A 250V fuse at the power input port as shown in Figure 4.

⚠️ WARNING:

This Automatic Voltage Regulator is NOT equipped with loss-Sensing Protection function or Over Excitation Protection. An additional Over-Voltage Protection device for the load may be required to avoid possible damage to the equipment or severe personal injury or death.

Mounting Guidelines:

  • The AVR can be mounted directly on the engine, genset, switchgear, control panel, or any other position that will not affect its operation.
  • For precise dimensions, refer to the Outline Drawing (Figure 2) in the diagram below.
Comprehensive diagram sheet for SHALUO SX460 AVR including outline drawing, frequency compensation curves, soft start curve, and wiring diagrams for 220VAC and 380VAC systems.

Figure 2: SHALUO SX460 AVR Outline, Performance Curves, and Wiring Diagrams

  • Figure 2.1 (Top Left): Outline Drawing - Shows physical dimensions (in mm) and terminal layout.
  • Figure 2.2 (Top Middle): Frequency Compensation Curves - Illustrates generator output voltage vs. frequency for 50Hz and 60Hz operation.
  • Figure 2.3 (Top Right): Soft Start Curve - Shows generator output voltage during the soft start phase.
  • Figure 2.4 (Bottom): Wiring and Adjustment (Figure 4) - Detailed wiring diagrams for 220VAC and 380VAC systems, including connections for AC stator winding, exciter field winding, voltage adjustment, fuse, input voltage selection, low frequency setting, and stability adjustment.

Important Considerations:

  • All voltage readings should be taken with an average-reading voltmeter.
  • Do NOT use Meggers or high-potential test equipment, as this can damage the AVR.

4. Operating Instructions

The SHALUO SX460 AVR is an automatic voltage regulator. Once correctly installed and wired according to the instructions in Section 3, it will automatically regulate the generator's output voltage. No manual adjustments are typically required during normal operation, other than initial setup and calibration if necessary.

  • Ensure all connections are secure before starting the generator.
  • Monitor the generator's output voltage to confirm stable regulation.
  • If voltage output is outside the desired range, refer to the 'External Volts Adjustment' specification and the troubleshooting section.

5. Maintenance

The SHALUO SX460 AVR is designed for reliable, long-term operation with minimal maintenance. However, following these general guidelines can help ensure its longevity:

  • Keep Clean: Ensure the AVR is kept free from dust, dirt, and debris. Use a soft, dry cloth to gently clean the exterior if necessary.
  • Environment: Operate the AVR within its specified environmental conditions (temperature, humidity) to prevent damage. Avoid exposure to excessive moisture or corrosive environments.
  • Connections: Periodically check all wiring connections to ensure they remain tight and free from corrosion.
  • Inspection: Visually inspect the AVR for any signs of physical damage, overheating (discoloration), or loose components.

No user-serviceable parts are inside the sealed unit. Do not attempt to open or repair the AVR yourself.

6. Troubleshooting

If you experience issues with your SHALUO SX460 AVR, consider the following basic troubleshooting steps:

  • No Voltage Output:
    • Check all wiring connections (F1, F2, sensing inputs) for proper contact and security.
    • Verify the generator is producing residual voltage at the AVR terminals (> 5 VAC).
    • Check the 5A 250V fuse at the power input port.
  • Unstable Voltage Output:
    • Ensure the frequency selection (50Hz/60Hz jumper) is correctly set for your generator.
    • Check for loose connections or intermittent faults in the sensing circuit.
    • Verify the generator's engine governing is stable.
  • Incorrect Voltage Output:
    • Adjust the external voltage trimmer (if installed) within its ±7% range.
    • Confirm the sensing input voltage selection (110V/220V) matches your generator's configuration.

If problems persist after performing these checks, it is recommended to consult a qualified technician or contact SHALUO support.

7. User Tips

No specific user tips were available from reviews or Q&A for this product.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your authorized SHALUO dealer or the official SHALUO customer service channels. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.