ANENJI ANJ-4000W-24V

Contents

ANENJI 4.2KW 24V Hybrid Solar Inverter Instruction Manual

Model: ANJ-4000W-24V

1. Introduction

This ANENJI 4.2KW 24V Hybrid Solar Inverter is a multi-functional inverter/charger designed to provide uninterruptible power support. It integrates the functions of an inverter, solar charger, and battery charger into a compact unit. The comprehensive LCD display allows for user-configurable and easily accessible button operation, enabling adjustments such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different application requirements. This inverter supports both on-grid and off-grid operations.

2. Safety Information

Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.

  • Ensure all connections are secure and correctly polarized.
  • Only qualified personnel should perform installation and wiring.
  • The inverter must be connected to a battery to function.
  • This device is rated IP21 for indoor use only. Do not expose to rain or moisture.
  • Ensure adequate ventilation around the inverter to prevent overheating.
  • Do not disassemble the inverter. There are no user-serviceable parts inside.
  • Wear appropriate personal protective equipment (PPE) during installation.

3. Product Features

  • Pure sine wave output.
  • Power factor 1.0.
  • Wide PV input voltage range: 60-500VDC.
  • Built-in MPPT 100A solar charge controller.
  • Lithium Battery Activation function.
  • Compatible with LiFePO4 batteries via RS485.
  • Detachable dust cover for protection in harsh environments.
  • Supports on-grid and off-grid operation.
  • Multiple output priorities: UTL (Utility), SOL (Solar), SBU (Solar-Battery-Utility), SUB (Solar-Utility-Battery).
  • Optional remote monitoring via WiFi module (sold separately).

4. Specifications

ParameterValue
Model NumberANJ-4000W-24V
Rated Power4200W
Output Power4000W
Size (L x W x H)450 x 350 x 160 mm
Weight7 KG
Brand NameANENJI
Output Frequency50/60HZ Auto sensing
Output Current100A
Input Voltage230VAC
Acceptable Voltage Range170-280VAC (Personal Computer); 90-280VAC (Home Appliances)
Output AC Voltage Regulation230VAC±5%
Surge Power7000VA
Transfer Time20ms (Home Appliances)
Wave FormPure sine wave
Maximum PV Array Power4500W
MPPT Range Operation Voltage60-500VDC
Maximum PV Array Open Circuit Voltage500VDC
Maximum Solar Charge Current100A
Maximum Efficiency98%
Humidity5% to 95% Relative Humidity (Non-condensing)
Operation Temperature-10℃ to 55℃
Storage Temperature-15℃ to 60℃
Ingress ProtectionIP21 (Indoor use)
Communication InterfaceRS232/RS485
CertificationsCE, RoHS Compliant

5. Package Contents

Upon unpacking, please verify that all items are present and undamaged:

  • ANENJI 4.2KW 24V Hybrid Solar Inverter x1
  • Instruction Manual x1

Note: The WiFi module and SPS board are sold separately and are not included in the standard package.

6. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. It is highly recommended that installation be performed by a certified electrician or solar professional.

6.1. System Overview

The inverter integrates various power sources to supply electricity to your home or appliances. The general system diagram illustrates how solar panels, a generator, the utility grid, and a battery connect to the inverter to power your loads.

System connection diagram showing solar panels, generator, utility grid, battery, inverter, and various household appliances.
Figure 6.1: General System Connection Diagram

6.2. Inverter Components and Connections

Familiarize yourself with the inverter's components and connection points:

Product overview diagram with numbered components: 1. LCD Screen, 2. Status Indicator, 3. Charge Indicator, 4. Fault Indicator, 5. Function Buttons, 6. On/Off Switch, 7. AC Input, 8. AC Output, 9. PV Input, 10. Battery Input, 11. Wire Outlet Hole, 12. Grounding.
Figure 6.2: Inverter Front and Rear Panel Overview

Key Components:

  1. LCD Screen: Displays system status and settings.
  2. Status Indicator: Shows the operational status of the inverter.
  3. Charge Indicator: Indicates battery charging status.
  4. Fault Indicator: Lights up in case of system errors.
  5. Function Buttons: Used for navigation and setting adjustments (ESC, UP, DOWN, ENTER).
  6. On/Off Switch: Main power switch for the inverter.
  7. AC Input: Terminal for connecting to the utility grid or a generator.
  8. AC Output: Terminal for connecting to household appliances/loads.
  9. PV Input: Terminal for connecting solar panels.
  10. Battery Input: Terminal for connecting the battery bank.
  11. Wire Outlet Hole: For routing cables.
  12. Grounding: Essential safety connection.

6.3. Wiring Procedure

Refer to the detailed connection terminals on the rear panel for accurate wiring. Ensure all connections are tight and properly insulated.

Detailed rear view of the inverter showing AC input, AC output, PV input, and battery input terminals, along with RS485/RS232 ports and an On/Off switch.
Figure 6.3: Inverter Rear Panel Connection Terminals

Wiring Steps:

  1. Grounding: Connect the inverter to a reliable ground source.
  2. Battery Connection: Connect the 24V battery bank to the Battery Input terminals (POS+ and NEG-). Ensure correct polarity.
  3. PV Input Connection: Connect your solar panel array to the PV Input terminals. Ensure the PV array voltage and current are within the inverter's specifications (Max PV Array Power 4500W, MPPT Range 60-500VDC, Max PV Array Open Circuit Voltage 500VDC).
  4. AC Input Connection: Connect the utility grid or generator to the AC Input terminals.
  5. AC Output Connection: Connect your loads/appliances to the AC Output terminals.
  6. Communication Ports: If using, connect RS232 or RS485 cables for monitoring or external communication.
  7. Secure Connections: Double-check all wiring for tightness and correct placement before powering on.

Watch this video for a visual guide on the wiring process:

Video 6.1: Inverter Wiring Demonstration

7. Operating Instructions

7.1. Powering On/Off

  1. Ensure all wiring is complete and secure.
  2. Turn on the battery breaker (if applicable).
  3. Flip the On/Off switch (Component 6 in Figure 6.2) on the inverter to the 'ON' position.
  4. The LCD screen will light up, and the inverter will begin its startup sequence.
  5. To power off, reverse the steps: turn off the inverter, then the battery breaker.

7.2. LCD Display and Button Functions

The LCD screen provides real-time information about the system status, including input/output voltage, battery level, and charging status. The function buttons (ESC, UP, DOWN, ENTER) allow you to navigate through menus and configure settings.

7.3. Configuration Settings

Through the LCD and buttons, you can configure various parameters:

  • Battery Charging Current: Adjust the current for optimal battery charging.
  • AC/Solar Charger Priority: Set whether the inverter prioritizes AC input or solar input for charging the battery.
  • Acceptable Input Voltage Range: Configure the voltage range for the AC input based on your connected devices (e.g., personal computers vs. home appliances).
  • Output Source Priority: Select the preferred power source for your loads (UTL, SOL, SBU, SUB).

7.4. Remote Monitoring (Optional)

If you have purchased and installed the optional WiFi module, you can monitor your inverter's performance and status remotely via a dedicated mobile application (e.g., SmartESS app). Refer to the WiFi module's separate instructions for setup and app usage.

Image showing the ANENJI inverter and a smartphone displaying the SmartESS app interface for remote monitoring.
Figure 7.1: Remote Monitoring via SmartESS App

8. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Keep the inverter clean and free from dust. The detachable dust cover can be removed for cleaning. Use a dry, soft cloth. Do not use liquid cleaners.
  • Ventilation: Ensure that the ventilation openings are not blocked. Maintain clear space around the inverter for proper airflow.
  • Connections: Periodically check all electrical connections (battery, PV, AC input/output) for tightness and signs of corrosion. Tighten any loose connections.
  • Environment: Ensure the inverter is operating within its specified temperature and humidity ranges (-10℃ to 55℃, 5% to 95% non-condensing humidity).

9. Troubleshooting

This section addresses common issues you might encounter. For more complex problems, please contact technical support.

  • Inverter not turning on:
    - Check if the battery is connected and charged. The inverter requires a battery to operate.
    - Ensure the On/Off switch is in the 'ON' position.
    - Verify all power connections are secure.
  • No AC output:
    - Check the AC output connections to your loads.
    - Verify the inverter is not in a fault state (check Fault Indicator).
    - Ensure the battery has sufficient charge.
  • Battery not charging:
    - Check PV input connections and ensure solar panels are receiving sunlight.
    - Verify AC input connection if AC charging is prioritized.
    - Check battery health and connections.
  • Overload warning:
    - Reduce the load connected to the inverter. The maximum output power is 4000W.
  • Inverter not connecting to battery (specific issue):
    - If you experience specific issues with battery connection, an SPS board might be required. Consult with technical support for diagnosis and ordering the correct SPS board if necessary.
  • Incorrect output voltage (e.g., expecting 127V):
    - This model provides a 230VAC output. It does not support 127V output.
  • PV array sizing:
    - Ensure your solar panel array's total power does not exceed 4500W and its open circuit voltage does not exceed 500VDC. For example, six 600W panels (3600W total) are within the power limit, but their voltage configuration must also be within the 60-500VDC MPPT range.

10. User Tips

  • Battery Connection is Essential: Always ensure the inverter is connected to a 24V battery bank for proper operation. It cannot function without a battery.
  • Remote Monitoring: For convenient monitoring of your solar system, consider purchasing the optional WiFi module and installing the SmartESS app.
  • PV Array Sizing: When connecting solar panels, carefully calculate the total wattage and voltage to stay within the inverter's maximum PV array power (4500W) and open circuit voltage (500VDC) limits.
  • Output Voltage: This inverter provides 230VAC output. Ensure your appliances are compatible with this voltage.
  • Battery Communication: Note that the battery communication function is not supported by this inverter model.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt and product serial number handy for faster service.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.