CFsunbird XY-L30A

Contents

XY-L30A Battery Charging Control Module

Model: XY-L30A | Brand: CFsunbird

Introduction

This manual provides detailed instructions for the operation and setup of the XY-L30A Battery Charging Control Module. This versatile module is designed for automatic charge control and time-based charging of various battery types, including lead-acid and lithium batteries, within a voltage range of 6V to 60V.

Features

  • Supports lead-acid and lithium batteries with a voltage range of 6V to 60V.
  • LCD display simultaneously shows voltage, battery charge percentage, and charging time.
  • Automatic charge control based on user-defined voltage thresholds.
  • Configurable charge time control function.
  • Parameters can be set directly on the module or uploaded via a serial port.

Specifications

Parameter Value
Product Model XY-L30A
Control Voltage DC 6-60V
Control Current <30A
Control Accuracy 0.1V
Output Type Direct Output
Voltage Error ±0.1V
Scope of Application Various lithium batteries, lead-acid batteries

Setup and Installation

The XY-L30A module is designed for direct output connection. Ensure all connections are secure before applying power.

Physical Overview

Top view of the XY-L30A Battery Charging Control Module showing LCD, buttons, relay, and screw terminals.
Figure 1: Top view of the XY-L30A module. Features include an LCD screen, three control buttons (UP, DOWN, SET), a blue relay, and screw terminals for connections.
Bottom view of the XY-L30A Battery Charging Control Module showing RX, TX, GND, CH+, CH-, BT+, BT- terminals.
Figure 2: Bottom view of the XY-L30A module. Shows serial communication pins (RX, TX, GND) and battery/charger connection points (CH+, CH-, BT+, BT-).

Wiring Connections

Connect your power source, battery, and charger to the appropriate screw terminals on the module. Refer to Figure 2 for terminal identification. Ensure correct polarity for all connections.

  • BT+ / BT-: Connect to the battery terminals.
  • CH+ / CH-: Connect to the charger output.
  • RX / TX / GND: For serial communication (advanced users).

Operating Instructions

1. Automatic Charge Control Function

This function charges the battery until it reaches a high voltage threshold and stops when it falls below a low voltage threshold.

  1. Set the upper voltage limit (volt-HI: 'UP') and lower voltage limit (volt-LI: 'dn').
  2. When the battery voltage drops below 'dn', the relay activates, and the charger begins charging.
  3. When the battery voltage reaches 'UP', the relay disconnects, and charging stops.

2. Charge Time Control Function

This function allows you to limit the charging duration.

  1. Enter the parameter settings and set the 'op' parameter to a non-zero value to enable time control. The default 'op' is '--:--h', which means time control is off.
  2. Once enabled, when the battery voltage is below 'dn', charging starts, and the system begins timing.
  3. If the battery voltage reaches 'UP' before the 'op' time expires, the relay disconnects.
  4. If the 'op' time expires and the battery voltage is still below 'dn', the relay remains connected, but the time control function automatically closes, and 'H:ER' flashes to indicate an unreasonable time setting. Press any key to stop the flashing.

Note: Time format is HH:MM (hours:minutes). Maximum time is 99:59 (100 hours).

3. Parameter Setting

  1. Press and hold the SET key to enter the setting interface.
  2. Short press SET to cycle through the parameters you wish to set.
  3. Use the UP / DOWN keys to adjust the selected parameter. Short press for incremental changes, long press for fast increase/decrease.
  4. Repeat steps b) and c) for other parameters.
  5. After setting all parameters, long press the SET key to exit and save the settings.

4. Key Function Description (Run Interface)

  • Short press SET: Displays the current set parameters.
  • Short press UP: Toggles display between charge percentage and charging time.
  • Short press DOWN: Toggles relay enabling (ON/OFF). If the relay is closed, 'off' will be displayed.
  • Long press UP: Switches low power state:
    • ON: Backlight turns off after 10 minutes of no operation.
    • OFF: Backlight remains continuously bright.
  • Long press SET: Enters parameter settings.

5. Calculation of Voltage Percentage

Voltage percentage = (Current Battery Voltage - volt-LI) / (volt-HI - volt-LI)

Maintenance

The XY-L30A module requires minimal maintenance. Keep the module clean and free from dust and moisture. Ensure all connections remain secure. Avoid exposing the module to extreme temperatures or direct sunlight for prolonged periods.

Troubleshooting

  • 'H:ER' Flashing: This indicates that the time parameter setting for the Charge Time Control function is unreasonable (e.g., the set time was too short for the battery to reach the 'UP' voltage). Press any key to stop the flashing. Re-evaluate and adjust your 'op' time setting.
  • 'ERR' Flashing: This appears if, during parameter setting, the lower voltage limit (volt-LI 'dn') is set to be greater than or equal to the upper voltage limit (volt-HI 'UP'). Ensure 'dn' is always less than 'UP'.
  • 'NbE' Displayed: This indicates that the battery is not properly connected to the module. Check your battery connections to the BT+ and BT- terminals.
  • Module not responding: Ensure the module is receiving power within the specified DC 6-60V range. Check all wiring for loose connections or shorts.

User Tips

  • Always double-check your voltage settings (volt-HI and volt-LI) to match your battery type and desired charge levels to prevent overcharging or undercharging.
  • When using the time control function, start with a generous time limit and observe the charging process to fine-tune the 'op' parameter for optimal results.
  • For critical applications, consider adding external over-current protection, although the module has a 30A current limit.

Warranty and Support

For warranty information and technical support, please refer to the seller's policies or contact the manufacturer directly. Keep your purchase records for any warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.