HYTAIS TS380, TS600

HYTAIS Non-Contact Infrared Thermometer User Manual

Models: TS380, TS600

1. Introduction

This series of HYTAIS infrared thermometers is designed to measure the surface temperature of opaque objects. The device's optical system senses reflected and transmitted energy, focusing it onto a detector. This makes it ideal for quickly measuring the surface temperature of various high-temperature, toxic, or hard-to-reach objects.

The thermometer comprises an optical system, a photoelectric sensor, a signal amplifier, a signal processing circuit, and an LCD display. The optical system concentrates infrared energy radiated from the object's surface onto the photoelectric sensor, which converts this energy into an electrical signal. This signal is then processed and displayed as a temperature reading on the LCD.

2. Safety Instructions

Warning:

  • To prevent potential harm, do not point the laser directly at eyes or indirectly through reflective surfaces.
  • The thermometer cannot measure through transparent surfaces like glass or plastic. The reading will reflect the surface temperature of the transparent object itself.
  • Steam, dust, smoke, or other particles can obstruct the instrument's lens, affecting measurement accuracy.

Attention:

To avoid damaging the thermometer or the equipment being measured, protect them from the following:

  • Electromagnetic fields (EMF) generated by arc welding machines, induction heaters, etc.
  • Thermal shock (large or sudden temperature changes). Allow 30 minutes for the thermometer to stabilize before use if exposed to significant temperature shifts.
  • Do not place or bring the thermometer close to high-temperature objects.

3. Key Features

  • 0.5-second Quick Measurement: Provides rapid temperature readings.
  • Laser Positioning: Equipped with a laser for precise targeting of the measurement area.
  • One-Touch Response: Simple operation for immediate measurements.
  • Adjustable Emissivity (0.1-1.00): Allows for accurate readings on various material surfaces.
  • High-Low Temperature Alert: User-settable alarms for temperatures exceeding or falling below specified limits.
  • Celsius/Fahrenheit Switch: Easily toggle between °C and °F units.
  • Backlight LCD Display: Clear readings in various lighting conditions.
  • Data Hold Function: Temporarily freezes the last measured reading on the display.
  • Auto Power Off: Conserves battery life by automatically shutting down after a period of inactivity.
  • Compact Size and Comfortable Grip: Ergonomic design for ease of use.
Hand holding HYTAIS infrared thermometer, showing display with 34.3°C, laser dot, and key features like quick measurement, laser positioning, adjustable emissivity, high-low temp alert, C/F switch, AAA batteries.
HYTAIS Infrared Thermometer in use, highlighting its quick measurement, laser positioning, adjustable emissivity, and temperature alert features.
Two HYTAIS infrared thermometers (TS380 and TS600) side-by-side, with text 'HYTAIS High-Precision Non-Contact Infrared Thermometer Easy operation, one-touch measurement'.
The TS380 and TS600 models, emphasizing easy, one-touch operation.

4. Specifications

FeatureTS380TS600
Measurement Range (°C)-50°C ~ 380°C-50°C ~ 600°C
Measurement Range (°F)-58°F ~ 716°F-58°F ~ 1112°F
Accuracy± (1.5% + 1.5)
Resolution0.1°C ~ 0.1
Adjustable Emissivity0.1 ~ 1.0 (preset 0.95)
Distance-to-Spot Ratio (D:S)12:1
°C/°F Temperature Range Switch
Auto Power Off
Data Hold
Backlight
Positioning Laser
PowerAAA*2 batteries
Table of specifications for TS380 and TS600 models, including measurement range, accuracy, resolution, adjustable emissivity, distance-to-spot ratio, C/F switch, auto power off, data hold, backlight, positioning laser, and power (AAA*2 batteries).
Detailed specifications for TS380 and TS600 models.

5. Setup

Battery Installation

  1. Open the battery compartment door.
  2. Insert two 1.5V AAA batteries, ensuring correct polarity.
  3. Close the battery compartment door securely.
Video demonstrating battery installation and initial power-on of the thermometer.
Two views of the thermometer, labeled components: laser emission point, temperature sensing area, measurement trigger, battery compartment, LCD display with backlight, Celsius/Fahrenheit switch, function switch, infrared laser switch.
Labeled diagram of the thermometer components, including the battery compartment.

6. Operating Instructions

Quick Measurement

  1. After installing batteries, pull the trigger to turn on the device.
  2. Aim the positioning laser at the surface of the object to be measured.
  3. Pull the trigger and the target temperature will be displayed on the LCD.
  4. Release the trigger to hold the data on the display. The device will automatically turn off after a few seconds of inactivity.

Locating Hot or Cold Spots

To find a hot or cold spot, first aim the thermometer at the outer edge of the area to be measured. Then, slowly move the thermometer up and down to scan the entire area until the hot or cold spot is located.

Function Switch Button (MODE)

After pulling and releasing the trigger, press the 'MODE' button to cycle through different display modes on the LCD: E (emissivity), MAX (maximum value), Hi (high temperature alarm setting), and LOW (low temperature alarm setting).

Infrared Indicator Switch Button

After pulling and releasing the trigger, press the '▲' button to toggle the positioning laser on or off. The laser symbol on the LCD will appear or disappear accordingly.

Celsius/Fahrenheit Toggle Button (°C/°F)

After pulling and releasing the trigger, press the '°C/°F' button to switch between Celsius and Fahrenheit temperature units.

Emissivity Adjustment

After pulling and releasing the trigger, press and hold the 'MODE' button until 'E=0.95' (or current emissivity) is displayed. Then, use the '°C/°F' or '▲' buttons to adjust the emissivity value from 0.1 to 1.00. This allows for more accurate readings on different material surfaces.

Thermometer showing display with 34.3°C, and text 'adjustable emissivity :0.1-1.00 Adjustable emissivity for different material surfaces to achieve precise measurement'.
Adjustable emissivity for precise measurements on various surfaces.

High/Low Temperature Alarm

After pulling and releasing the trigger, press and hold the 'MODE' button, then briefly press 'MODE' to select either the high (Hi) or low (LOW) temperature alarm setting. Use the '°C/°F' or '▲' buttons to set the desired alarm temperature point. When the measured temperature exceeds the high limit or falls below the low limit, the indicator light above the display will illuminate.

Hand holding thermometer, showing display with 34.3°C, laser dot, and text 'temperature warning setting temperature upper and lower limits' with red 'Upper limit' and green 'Lower limit' indicators.
Temperature warning feature with upper and lower limit settings.

7. Distance-to-Spot Ratio (D:S)

When measuring temperature, it is important to consider the ratio between the distance to the object and the size of the measurement area. As the distance between the device and the object increases, the measurement area will also increase. This instrument has a D:S ratio of 12:1.

The device is equipped with a positioning laser to help aim at the surface of the object being measured. Ensure that the target being measured is larger than the diameter of the thermometer's light spot. For accurate measurements, the target should be at least twice the diameter of the light spot.

Diagram explaining Distance-to-Spot Ratio (D:S=12:1) with distances and spot sizes.
Illustration of the 12:1 Distance-to-Spot Ratio.

8. Emissivity

Emissivity describes how effectively a material radiates energy. Most organic materials and surfaces that are painted or oxidized have an emissivity of 0.95. The preset emissivity of this thermometer is 0.95.

Measuring shiny metal surfaces may result in inaccurate readings. To compensate, you can cover the surface with opaque adhesive tape or flat black paint (for temperatures below 148°C/300°F). Allow time for the cover to reach the same temperature as the surface, then measure the temperature of the covered area.

This thermometer allows you to adjust the emissivity based on the type of surface being measured. Refer to the table below for common material emissivity values:

Material NameSpecificationEmissivity
Human Skin0.98
LeadOxidized0.20-0.40
CopperOxidized0.40-0.80
IronOxidized0.60-0.90
SteelOxidized0.70-0.90
Asbestos0.95
Gypsum0.80-0.90
Asphalt0.95
Ceramic0.95
Wood0.90-0.95
Charcoal Powder0.96
LacquerwareMatte Finish0.97
Carbon0.90
Rubber0.95
Snow0.83-0.90
Ice0.96-0.98
LeadPolished0.02-0.04
GraphiteOxidized0.60
CopperPolished0.02-0.05
Gold0.01-0.10
PlasticTransparency > 0.5mm0.95
Iron0.85-
Steel0.70-0.90
Concrete0.95
Cement0.96
Soil0.98
Stucco0.91
Brick0.96
Marble0.94
Textile0.90
PaperVarious Colors0.94
Sand0.90
Mud0.92-
Water0.93
Gravel0.95
Glass0.85-
Tableware0.92

9. LCD Display and Buttons

LCD Display Elements:

  • A: Temperature measurement reading
  • B: Temperature measurement unit symbol (°C/°F)
  • C: Low temperature alarm symbol
  • D: Data hold symbol
  • E: Read data symbol
  • F: High temperature alarm symbol
  • G: Laser positioning symbol
  • H: Low battery symbol
  • I: Maximum value measurement symbol (MAX)
  • J: Emissivity symbol (E)
Two views of the thermometer, labeled components: laser emission point, temperature sensing area, measurement trigger, battery compartment, LCD display with backlight, Celsius/Fahrenheit switch, function switch, infrared laser switch.
Detailed view of the LCD display and physical buttons.

10. Product Maintenance

Lens Cleaning:

Use clean compressed air to blow away any debris. Then, use a camel hair brush to gently remove any remaining small particles. Finally, carefully wipe the surface with a damp cotton cloth.

Shell Cleaning:

Use a wet sponge or a soft cloth with soap and water to clean the exterior of the device.

Note:

  • Do not use any solvents to clean the plastic lens.
  • Do not immerse the thermometer in water.

11. Troubleshooting

  • No Display/Power On: Check battery installation and ensure batteries are not depleted. Replace with fresh AAA batteries if necessary.
  • Inaccurate Readings: Verify that the emissivity setting matches the material being measured. Ensure the distance-to-spot ratio is appropriate for the target size. Avoid measuring through transparent surfaces.
  • Laser Not Working: Check if the laser is enabled using the '▲' button.
  • Alarm Not Triggering: Confirm that the high/low temperature alarm limits are set correctly and the alarm function is active.

12. User Tips

  • For general household use, such as checking refrigerator temperatures or the temperature of cooking surfaces, the default emissivity setting of 0.95 is often sufficient.
  • When checking for drafts or insulation issues in a house, use the 'Locating Hot or Cold Spots' method to scan walls and windows for temperature variations.
  • Remember that the device measures surface temperature, not internal temperature. It is not intended for measuring human or animal body temperature.

13. Warranty & Support

Thank you for choosing our product. We provide excellent after-sales service to address any concerns you may have.

Warranty Policy:

  1. The warranty period for this product is one year from the date of purchase.
  2. During the warranty period, free repairs will be provided for malfunctions occurring under normal use conditions as specified in this user manual. Please present the original warranty card and purchase receipt. You may send the product directly to our company or hand it over to an authorized dealer.
  3. Damages caused by improper use, natural wear and tear, unauthorized disassembly for self-repair, or accidents are not covered by the free warranty.
  4. For cases not covered by the free warranty, our company can provide non-free repairs, with charges applied accordingly.
  5. The product must be repaired by our company's professional staff. If unauthorized disassembly or repair is performed, the warranty will be void.

14. Additional Documents

A detailed user manual in PDF format is available for download: User Manual (PDF)

Related Documents - TS380, TS600

Preview HYTAIS TS380/TS600 Infrared Thermometer User Manual
User manual for HYTAIS TS380 and TS600 non-contact infrared thermometers, detailing features, safety instructions, operation, maintenance, and specifications for accurate surface temperature measurement.
Preview HYTAIS TS600 Digital Infrared Thermometer Gun User Manual
User manual for the HYTAIS TS600 digital infrared thermometer gun, detailing its features, operation, safety precautions, maintenance, and warranty information.
Preview HYTAIS TS-U7 Fully Automatic Recognition Multimeter User Manual
Comprehensive user manual for the HYTAIS TS-U7 Fully Automatic Recognition Multimeter. Learn about its features, specifications, operation, and safety guidelines for accurate electrical measurements.
Preview HYTAIS TS20A Pen-Type Digital Multimeter User Manual
User manual for the HYTAIS TS20A pen-type digital multimeter, detailing its features, operation, safety precautions, and specifications for measuring AC/DC voltage, resistance, and continuity.