eletechsup 25IOA08 25IOB16 25IOC32

Contents

Instruction Manual for eletechsup Modbus RS485 IO Expansion Board

Models: 25IOA08, 25IOB16, 25IOC32

1. Introduction

The eletechsup 25IOA08, 25IOB16, and 25IOC32 series are advanced Modbus RS485 IO modules designed for industrial control and automation applications. These modules feature 8, 16, or 32 channels of photoelectrically isolated NPN/PNP inputs and corresponding DMOS PNP outputs. They are ideal for PLC IO expansion, remote control systems, smart home integration, security monitoring, and LED lamp driving.

This manual provides detailed instructions for the setup, operation, and maintenance of your eletechsup Modbus RS485 IO Expansion Board.

2. Specifications

FeatureDescription
Model Numbers25IOA08 (8-channel), 25IOB16 (16-channel), 25IOC32 (32-channel)
Brandeletechsup
TheorySolid State Relay
Power SourceDC 7-25V (compatible with 9V, 12V, 24V)
Working Current8-50mA
Input Channels8/16/32 photoelectrically isolated NPN/PNP (optional)
Output Channels8/16/32 DMOS PNP outputs (high level)
Max Output Drive Current300mA per channel
Output ModesOpen/Close/Toggle (Self-locking)/Latch(Inter-locking)/Momentary (Non-locking)/Delay
Modbus Command 1 Support03, 06, 16 function codes; Max delay 255 seconds
Modbus Command 2 Support01, 02, 03, 05, 06, 15, 16 function codes
Parallel DevicesUp to 64 devices in Modbus command mode
Baud RateDefault 9600BPS; Settable: 1200/2400/4800/19200/38400/57600/115200BPS
Dimensions (Board Only)8CH: 61x72x18MM; 16CH: 106x72x18MM; 32CH: 196x72x18MM
Dimensions (With DIN Box)8CH: 64x80x30MM; 16CH: 109x80x30MM; 32CH: 199x80x30MM
Weight (Board Only)8CH: 46g; 16CH: 80g; 32CH: 152g
Weight (With DIN Box)8CH: 85g; 16CH: 145g; 32CH: 247g
CertificationCE
Protection FeatureEpoxy

3. Setup and Wiring

Proper wiring is essential for the safe and correct operation of the Modbus IO module. Ensure all power is disconnected before making any connections.

3.1 General Wiring Diagram

Wiring diagram of driving PLC amplifier board
Figure 3.1: General wiring diagram showing connections to a PLC amplifier board.

This diagram illustrates the basic connections for driving a PLC amplifier board. Ensure correct polarity for power supply and signal lines.

3.2 Modbus RS485 Connection

The module communicates via RS485. Connect the A+ and B- terminals to your RS485 master device (PC via USB-RS485 adapter or PLC). Up to 64 devices can be connected in parallel on the same bus.

Modbus connection diagram for PC and PLC
Figure 3.2: Modbus RS485 connection diagram showing multiple modules connected to a PC or PLC.

3.3 Power Supply and Inputs/Outputs

The module requires a DC 7-25V power supply connected to the VIN and GND terminals. The input channels (IN1-IN32) support NPN/PNP photoelectric isolation, and the output channels (CH1-CH32) are DMOS PNP outputs with a high-level output and 300mA drive current.

Overview of 8, 16, and 32 channel NPN/PNP DI & PNP DO RS485 Remote IO modules
Figure 3.3: Visual representation of 8, 16, and 32 channel modules, highlighting NPN/PNP inputs and PNP outputs.
Detailed view of the 8CH NPN Input PNP Output board
Figure 3.4: Close-up of an 8-channel module, showing input and output terminals, DIP switches, and M0 port.

3.4 DIP Switch and M0 Port Configuration

  • **DIP Switches**: Used for setting the Modbus address and baud rate. Refer to the product's detailed protocol documentation for specific switch configurations.
  • **M0 Port**: This port is used for command selection.
  • **RESET Port**: Short-circuit the RESET port for 5 seconds to restore the module to factory settings.

4. Operating Instructions

The module operates using Modbus RTU commands over the RS485 bus. You can control outputs, read inputs, and configure settings using a Modbus master device.

4.1 Controlling Switch Outputs (Application 1)

To control the 8/16/32 channel switch outputs via the RS485 bus, send appropriate Modbus commands to the module. The maximum drive current per channel is 300mA, and the high output level is approximately Supply Voltage - 1.2V.

Application 1: Control 8/16/32CH Switch Output Through RS485 bus
Figure 4.1: Wiring for controlling switch outputs via RS485.

4.2 Reading Switch Inputs (Application 2)

You can read the status of the 8/16/32 channel switch inputs using Modbus commands. The inputs support 3-24V NPN or PNP signals.

Application 2: Read 8/16/32CH Switch Input via RS485 bus
Figure 4.2: Wiring for reading NPN and PNP switch inputs via RS485.

4.3 Input Directly Controls Output (Application 3)

In this mode, an input signal directly controls a corresponding output. This functionality requires specific Modbus register configuration. To enable this, you need to configure register 0x00FA (decimal 250).

Application 3: Input and Output Amplifier (Input directly controls output)
Figure 4.3: Wiring for direct input-to-output control (NPN and PNP inputs shown).

4.4 Remote IO Control (Application 4)

Two or more modules can be linked via RS485 for remote IO control, where inputs on one board control outputs on another. Ensure all RS485 addresses are unique and configure the Remote IO Sender/Receiver Enable registers (0x00F5 and 0x00F6 respectively).

Application 4: 8-32CH Input Remote Control 8-32CH Output
Figure 4.4: Diagram for remote IO control between two modules.

4.5 Modbus Command Functions

  • **Modbus Command 1**: Supports function codes 03 (Read Holding Registers), 06 (Write Single Register), and 16 (Write Multiple Registers).
  • **Modbus Command 2**: Supports function codes 01 (Read Coils), 02 (Read Discrete Inputs), 03 (Read Holding Registers), 05 (Write Single Coil), 06 (Write Single Register), 15 (Write Multiple Coils), and 16 (Write Multiple Registers).
  • **Output Modes**: The default command supports various output modes including Open, Close, Toggle (Self-locking), Latch (Inter-locking), Momentary (Non-locking), and Delay.

4.6 Modbus Poll Software Demonstration

The following video demonstrates the use of Modbus Poll software to interact with the module, showing how to establish a connection and send commands.

Video 4.1: Demonstration of Modbus Poll software with the eletechsup IO module.

5. Maintenance

The eletechsup Modbus IO module is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure longevity:

  • **Keep Clean**: Regularly clean the module and its surroundings to prevent dust and debris accumulation, which can affect performance and heat dissipation. Use a soft, dry cloth.
  • **Environmental Conditions**: Operate the module within its specified temperature and humidity ranges. Avoid exposure to extreme temperatures, direct sunlight, or corrosive environments.
  • **Secure Connections**: Periodically check all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to intermittent operation or damage.
  • **Power Supply Stability**: Ensure a stable and clean power supply within the specified voltage range (DC 7-25V). Voltage fluctuations can impact the module's performance.
  • **Firmware Updates**: Check the manufacturer's website for any available firmware updates. Follow the provided instructions carefully if performing an update.

6. Troubleshooting

If you encounter issues with your Modbus IO module, refer to the following troubleshooting tips:

  • **No Power/Indicators Off**:
    • Verify the power supply voltage is within DC 7-25V.
    • Check power connections for proper polarity and secure contact.
    • Ensure the power supply is functional.
  • **No RS485 Communication**:
    • Check RS485 A+ and B- wiring for correct polarity and secure connections.
    • Verify the Modbus address of the module matches the address configured in your master device.
    • Confirm the baud rate and parity settings on the module (via DIP switches) match your master device.
    • Ensure the RS485 bus is properly terminated if necessary (for long distances or multiple devices).
    • Check for bus conflicts if multiple devices are on the same RS485 line.
  • **Inputs Not Responding**:
    • Verify the input signal voltage is within the 3-24V range.
    • Check if the input type (NPN/PNP) of the module matches the sensor/switch connected.
    • Ensure input wiring is correct and secure.
    • Confirm that the Modbus master is reading the correct input registers.
  • **Outputs Not Activating**:
    • Verify the load connected to the output does not exceed 300mA.
    • Check output wiring for secure connections and correct polarity.
    • Confirm that the Modbus master is writing to the correct output registers/coils.
    • If using direct input-to-output control (Application 3), ensure register 0x00FA (250) is configured correctly.
    • If using remote IO control (Application 4), verify sender/receiver enable registers (0x00F5, 0x00F6) and RS485 addresses are correctly set.
  • **Module Overheating**:
    • Ensure adequate ventilation around the module.
    • Verify that the output loads do not exceed the maximum current rating.
    • Check the ambient temperature to ensure it's within the operating range.

If the problem persists after checking these points, consider restoring factory settings using the RESET port or contacting technical support.

7. User Tips

To maximize the performance and reliability of your eletechsup Modbus IO module, consider these user tips:

  • **Documentation**: Always refer to the detailed Modbus protocol documentation provided by eletechsup for specific register addresses, command structures, and DIP switch settings.
  • **Testing**: Before deploying in a critical application, thoroughly test all inputs, outputs, and communication functions in a controlled environment.
  • **Grounding**: Ensure proper grounding practices are followed in your installation to minimize electrical noise and improve signal integrity.
  • **Cable Quality**: Use high-quality shielded twisted-pair cables for RS485 communication, especially over longer distances, to prevent interference.
  • **Software Tools**: Utilize Modbus master software (like Modbus Poll) during development and troubleshooting to easily monitor and control the module.
  • **NPN vs. PNP**: Double-check the input type (NPN or PNP) of your sensors and configure the module accordingly to avoid damage or incorrect readings.