1. Introduction and Overview
The ZEEWEII DSO1C81 is a compact and versatile 2.8-inch handheld digital oscilloscope designed for a wide range of electrical measurement tasks. It features a 100M bandwidth, 250MSa/s sampling rate, and includes a built-in signal generator. This device is equipped with advanced functions such as a frequency meter, FFT analysis, ZOOM, persistence, roll mode, single trigger, and cursor measurement, making it suitable for both beginners and experienced users in various DIY and professional electrical applications.

Figure 1: ZEEWEII DSO1C81 Handheld Digital Oscilloscope
2. Package Contents
Please check the box for the following items:
- ZEEWEII DSO1C81 Digital Oscilloscope
- P6100 Probe
- USB Cable
- Instruction Manual
- Storage Box

Figure 2: Included items in the package
3. Product Features
The DSO1C81 offers a range of features for comprehensive signal analysis:
- High Bandwidth & Sampling Rate: 80MHz bandwidth and 250MSa/s real-time sampling rate for accurate signal capture.
- Built-in Signal Generator: Capable of outputting sine, square, and triangle waves with adjustable frequency (0-2MHz) and fixed 3V amplitude. Useful for probe calibration and circuit debugging.
- Advanced Measurement Functions: Includes a 6-digit high-precision frequency meter, pulse counter, FFT (Fast Fourier Transform) analysis, and X/Y cursor measurement.
- ZOOM Mode: Allows detailed inspection of waveforms by displaying two waveforms at different time bases.
- Persistence & Roll Mode: Features for observing signal changes over time.
- Single Trigger: Captures non-repeating or single-shot events.
- Save Picture Function: Easily save waveform screenshots for later analysis.
- User-Friendly Interface: 2.8-inch LCD display with 320*240 resolution, intuitive button layout, and one-key auto function for quick setup.
- Portable Design: Compact size with a built-in lithium battery for 5-6 hours of continuous use on a full charge, supporting up to 1.2A fast charging.

Figure 3: Advanced features of the DSO1C81
4. Setup
4.1 Initial Charging
Before first use, fully charge the built-in lithium battery using the provided USB cable. Connect the USB cable to the oscilloscope's charging port and a standard USB power adapter (not included). The charging indicator will show the charging status.

Figure 4: Built-in lithium battery for portability
4.2 Probe Connection
Connect the P6100 probe to the BNC probe connection socket on the top of the oscilloscope. Ensure a secure connection. The two small tabs next to the BNC connector are the output of the signal generator.

Figure 5: BNC probe connection socket and silicone keys
4.3 Power On/Off
Press and hold the 'Func' button (power symbol) to turn the device on or off.
5. Operating Instructions
The DSO1C81 features an intuitive button layout for easy operation. Refer to the video demonstration for a visual guide to key functions.
Video 1: Demonstration of DSO1C81 oscilloscope functions including time base, vertical sensitivity, auto, single trigger, persistence, roll, FFT, zoom, save, frequency meter, counter, and 220V measurement.
5.1 Basic Controls
- OK/Auto Button: Press for one-key automatic waveform adjustment.
- Arrow Buttons (Up/Down/Left/Right): Navigate menus, adjust parameters, and move cursors.
- Run/Stop Button: Start or pause waveform acquisition.
- Menu Button: Access the main menu for advanced settings.
- mV↑ / V↓ Buttons: Adjust vertical sensitivity (voltage per division).
- s / ns Buttons: Adjust time base (time per division).
5.2 Key Functions
5.2.1 Time Base Adjustment
Use the 's' and 'ns' buttons to adjust the horizontal time scale, allowing you to view more or less of the waveform on the screen. This is crucial for observing different frequencies and signal durations.
5.2.2 Vertical Sensitivity Adjustment
Use the 'mV↑' and 'V↓' buttons to adjust the vertical voltage scale. This changes the amplitude representation of the waveform, allowing you to accurately measure voltage levels.
5.2.3 Auto Mode
Press the 'OK/Auto' button to automatically adjust the time base and vertical sensitivity to display a stable waveform. This is particularly useful for quickly getting a view of an unknown signal.
5.2.4 Single Trigger
The single trigger mode is used to capture non-repeating or single-shot events. Once triggered, the oscilloscope will capture and display the waveform, then stop. This prevents continuous refreshing and allows for detailed analysis of transient signals.
5.2.5 Persistence
Persistence mode allows you to observe how waveforms change over time by overlaying multiple acquisitions. This can reveal signal anomalies, jitter, or infrequent events that might be missed in normal acquisition modes.
5.2.6 Roll Mode
In roll mode, the waveform scrolls across the screen from right to left, similar to a chart recorder. This is useful for observing very slow-changing signals or long-duration events without triggering.
5.2.7 FFT (Fast Fourier Transform)
The FFT function transforms the time-domain waveform into its frequency components, allowing you to analyze the spectral content of a signal. This is invaluable for identifying harmonics, noise, and signal integrity issues. The DSO1C81 uses a base-4 butterfly algorithm for faster and higher resolution FFT analysis.

Figure 6: FFT Spectrum analysis
5.2.8 ZOOM Mode
The ZOOM mode allows you to magnify specific sections of a captured waveform. This is particularly useful for examining fine details or anomalies within a larger signal. The screen can display two waveforms at two time bases, enabling detailed expansion.

Figure 7: Waveform in ZOOM mode
5.2.9 Save Image
The oscilloscope allows you to save screenshots of the displayed waveforms. This is useful for documentation, sharing, or further analysis on a computer.
5.2.10 Frequency Meter
The built-in 6-digit high-precision frequency meter provides accurate frequency readings of the input signal. It can measure frequencies from 10Hz to 30MHz.

Figure 8: 6-digit frequency meter display
5.2.11 Pulse Counter
The device includes a pulse counter function, which can be used to count the number of pulses in a signal.
5.2.12 Signal Generator
The integrated signal generator can output various waveforms (sine, square, triangle) with adjustable frequencies (0-2MHz) and a fixed 3V amplitude. This is useful for testing circuits and calibrating probes.

Figure 9: Built-in signal generator
5.2.13 Cursor Measurement
The X/Y cursor measurement feature allows you to manually position cursors on the waveform to measure time differences (between X cursors) and voltage differences (between Y cursors) accurately.

Figure 10: Cursor measurement in action
6. Specifications
| Parameter | DSO1C81 | Parameter | DSO1C81 |
|---|---|---|---|
| Model | DSO1C81 | Coupling | AC/DC |
| Channel | 1 | Auto mode | yes |
| Screen | 2.8 inch | Measure item | 14 types |
| Sampling rate | 250MSa/s | DC error | ±3% |
| Bandwidth | 80MHz | Freq-meter | 10Hz~30MHz |
| Equivalent sample | 500M | Save picture | yes |
| Rise time | <4ns | Freq-accuracy | ±0.01% |
| Storage depth | 480Kbit(60Kpts) | Pulse counter | yes |
| Impedance | 1MΩ | FFT | yes |
| Time base | 5ns – 10s | Generator | sin/square/triangular... |
| Vertical sensitivity | X1:10mV/div~10V/div X10:100mV/div~100V/div | Generator | 3V |
| Max voltage | 40V (x1) 220V (x10) | Vol / freq | 1Hz~1MHz |
| Trigger mode | auto/normal/single | Dimensions | 12*8*3.2cm |
| Trigger type | rise/fall | Resolution | 320x240 |
| Scan mode | YT / XY / Roll | Language | Chinese/English |
| Persistence | none/1s / ∞ | Charging | Type-C 5V |
| Material | ABS |
Figure 11: Detailed product specifications
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the oscilloscope in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Recharge the device regularly, even if not in use for extended periods.
- Probe Care: Handle the probe carefully. Avoid bending or stressing the cable. Keep the probe tip clean.
8. Troubleshooting
- No Power: Ensure the battery is charged. Connect the USB cable and try powering on again.
- No Waveform Display: Check probe connections. Ensure the input signal is within the oscilloscope's voltage range. Try the 'OK/Auto' function to automatically adjust settings.
- Unstable Waveform: Adjust the trigger level and trigger mode. Ensure the time base and vertical sensitivity are appropriate for the signal being measured.
- Inaccurate Readings: Perform probe compensation if necessary. Ensure the probe attenuation setting (X1/X10) matches the physical switch on the probe.
9. User Tips
- Check Probe Settings: Always ensure the probe's attenuation switch (X1 or X10) matches the setting selected on the oscilloscope's menu to get accurate voltage readings.
- Start with Auto: For unfamiliar signals, use the 'OK/Auto' button first to get a quick, stable display, then fine-tune the settings manually.
- Consider Dimensions: The device dimensions are 12*8*3.2cm, which is compact and suitable for handheld use.
10. Warranty and Support
The ZEEWEII DSO1C81 Digital Oscilloscope comes with a standard manufacturer's warranty. For technical support, warranty claims, or service inquiries, please refer to the contact information provided with your purchase or visit the official ZEEWEII website. Keep your proof of purchase for warranty validation.