1. Introduction
The ZEEWEII DSO1C81 is a compact and versatile handheld digital oscilloscope designed for electrical measurements and signal analysis. It features a 2.8-inch LCD display, 100MHz bandwidth, and a 250MSa/s sampling rate. This device integrates multiple functions including an oscilloscope, signal generator, frequency meter, and pulse counter, making it suitable for various applications from DIY circuit debugging to auxiliary learning.

2. Safety Information
Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the product.
- Do not use the device in wet or damp conditions.
- Avoid exposing the device to extreme temperatures or direct sunlight.
- Ensure proper probe connection and voltage settings before taking measurements.
- Do not attempt to open or modify the device, as this will void the warranty and may cause harm.
- Use only the provided accessories or approved replacements.
3. Package Contents
Verify that all items listed below are included in your package:
- ZEEWEII DSO1C81 Digital Oscilloscope (Equipment)
- P6100 Probe
- USB Cable
- Instruction Manual
- Storage Box

4. Product Overview
The DSO1C81 features a 2.8-inch LCD display with 320x240 resolution, housed in a durable ABS shell with comfortable silicone keys. It includes a BNC probe connection socket and two small tabs for signal generator output.

Key Features:
- High Bandwidth: 80MHz for accurate signal measurement across a wide frequency range.
- High Sampling Rate: 250MSa/s for detailed waveform capture.
- Large Storage Depth: 480Kbit (60kpts) for extensive waveform analysis.
- Integrated Functions: Oscilloscope, Signal Generator, Frequency Meter, Pulse Counter.
- User-Friendly: One-key auto mode for quick setup, suitable for beginners.
- Portable: Built-in lithium battery for 5-6 hours of continuous use on a full charge.


5. Setup
5.1 Charging the Device
The DSO1C81 comes with a built-in lithium battery. Before first use, or when the battery is low, connect the device to a 5V power source using the provided USB Type-C cable. The device supports up to 1.2A fast charging and offers 5-6 hours of continuous use on a full charge.
5.2 Connecting the Probe
- Ensure the oscilloscope is powered off.
- Connect the BNC connector of the P6100 probe to the BNC probe connection socket on the top of the oscilloscope.
- Attach the probe clip to the circuit point you wish to measure.
- For accurate measurements, ensure the probe is properly calibrated (refer to the 'Operating Instructions' for probe calibration using the signal generator).
6. Operating Instructions
The DSO1C81 offers a range of functions accessible via its intuitive button layout. The device supports continuous automatic mode and one-key auto for quick setup.

6.1 Basic Operation
- Power On/Off: Press and hold the 'Func' button (power symbol) to turn the device on or off.
- OK/Auto: Press 'OK Auto' for automatic waveform adjustment, simplifying initial setup.
- Run/Stop: Use 'Run Stop' to pause or resume waveform acquisition.
- Menu: Access various settings and functions.
- Navigation Buttons: Use the arrow keys (up, down, left, right) to navigate menus and adjust parameters.
- mV↑ / V↓: Adjust vertical sensitivity.
- s / ns: Adjust time base.
6.2 Advanced Features
Time Base and Vertical Sensitivity
Adjust the 's/ns' buttons for time base and 'mV↑/V↓' buttons for vertical sensitivity to scale the waveform display as needed. The device can automatically adjust these settings using the 'OK Auto' button.
Single Trigger
The single trigger mode allows capturing a single event or non-repeating signal. Once triggered, the waveform is displayed and acquisition stops until manually reset.
Persistence
Persistence mode displays multiple waveform acquisitions overlaid, allowing observation of signal variations and glitches over time.
Roll Mode
Roll mode is useful for observing slow-changing signals, where the waveform scrolls across the screen continuously.
FFT Spectrum Analysis
The DSO1C81 supports FFT (Fast Fourier Transform) spectrum analysis, utilizing a base-4 butterfly algorithm for faster calculation and higher resolution. This allows for measuring FFT frequency with a cursor.

ZOOM Mode
In Zoom mode, the screen is divided into two sections: a large time base waveform and a smaller, expanded time base waveform. This feature is useful for bus timing and amplitude modulation signal analysis, allowing for detailed examination of specific waveform sections due to large storage depth.

Cursor Measurement
The device supports X/Y cursor measurements, enabling you to manually position cursors to measure time differences between left and right cursors, and voltage differences between upper and lower cursors.

Frequency Meter and Pulse Counter
The DSO1C81 includes a 6-digit high-precision hardware frequency meter (FPGA-based) for accurate frequency display, such as crystal oscillator frequencies. It also features a pulse counter to count the number of pulses.

Signal Generator
The built-in signal generator can output various waveforms including sine, square, and triangle waves. The amplitude is fixed at 3V, and the frequency is adjustable from 0-2MHz. This function is useful for probe calibration, DIY circuit debugging, and educational purposes.

Saving Images
The device allows saving screenshots of waveforms for later review or documentation.
6.3 Operational Demonstration Video
7. Specifications
The following table details the technical specifications of the ZEEWEII DSO1C81 Digital Oscilloscope:
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Model | DSO1C81 | Coupling | AC/DC |
| Channel | 1 | Auto mode | Yes |
| Screen | 2.8 inch | Measure item | 14 types |
| Sampling rate | 250MSa/s | DC error | ±3% |
| Bandwidth | 80MHz | Freq-meter | 10Hz~30MHz |
| Equivalent sample | 500M | Save picture | Yes |
| Rise time | <4ns | Freq-accuracy | ±0.01% |
| Storage depth | 480Kbit (60kpts) | Pulse counter | Yes |
| Impedance | 1MΩ | FFT | Yes |
| Time base | 5ns – 10s | Generator | Sin/Square/Triangular... |
| Vertical sensitivity | X1:10mV/div~10V/div, X10:100mV/div~100V/div | Generator Vol / Freq | 3V, 1Hz~1MHz |
| Max voltage | 40V (x1), 220V (x10) | Dimensions | 12 * 8 * 3.2cm |
| Trigger mode | Auto/Normal/Single | Resolution | 320x240 |
| Trigger type | Rise/Fall | Language | Chinese/English |
| Scan mode | YT/XY/Roll | Charging | Type-C 5V |
| Persistence | None/1s/∞ | Material | ABS |

8. Troubleshooting
If you encounter issues with your DSO1C81, please refer to the following common problems and solutions:
- No Power: Ensure the device is fully charged. Connect the USB Type-C cable to a 5V power source and allow it to charge for at least 30 minutes before attempting to power on again.
- No Waveform Display: Check probe connections. Ensure the probe is securely connected to both the oscilloscope and the circuit under test. Verify that the input signal is within the device's voltage range. Try using the 'OK Auto' function to automatically adjust settings.
- Distorted Waveform: Check probe compensation. Adjust the probe's compensation if necessary. Ensure the probe is set to the correct attenuation (e.g., X1 or X10) matching the oscilloscope's settings.
- Inaccurate Measurements: Perform probe calibration using the built-in signal generator. Ensure the device is operating within its specified temperature range.
- Screen Frozen: Try restarting the device by holding down the power button. If the issue persists, contact customer support.
9. Maintenance
To ensure the longevity and optimal performance of your DSO1C81, follow these maintenance guidelines:
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the oscilloscope in a cool, dry place away from direct sunlight and extreme temperatures. When not in use for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.
- Probe Care: Handle the probe carefully. Avoid bending or stressing the cable. Keep the probe tip clean.
10. User Tips
Based on common usage scenarios and feedback, here are some tips to enhance your experience with the DSO1C81:
- Start with Auto: For beginners, always use the 'OK Auto' function first to get a stable waveform display. Then, fine-tune the time base and vertical sensitivity manually for more detailed analysis.
- Probe Calibration: Regularly calibrate your probe using the internal signal generator to ensure measurement accuracy, especially when switching between different probes or after long periods of use.
- Utilize Zoom: For complex signals or when examining specific parts of a waveform, the 'ZOOM' mode is invaluable for detailed inspection.
- Save Important Waveforms: Use the 'Save picture' function to document important measurements or interesting signal behaviors for later reference or sharing.
- Understand FFT: The FFT function is powerful for analyzing the frequency components of a signal. Experiment with it to identify harmonics or noise frequencies in your circuits.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the seller's policies or contact the ZEEWEII Official Store directly. Keep your purchase receipt as proof of purchase.