KKMOON XY-SK120

Contents

XY-SK120 120W CNC DC Adjustable Voltage Regulator Power Supply User Manual

Model: XY-SK120 | Brand: KKMOON

1. Introduction

The XY-SK120 is a programmable DC buck-boost power supply module featuring a full-angle VA color LCD screen for clear display of all information. Designed for professionals and enthusiasts, it offers constant voltage (CV), constant current (CC), and constant power (CW) modes, with a wide input voltage range of 6.0-36.00V and an output range of 0-36.00V. This module supports firmware upgrades, multiple protective systems, and advanced communication capabilities including serial communication, web-based PC software, and mobile app (Android/iOS) control. Its cloud connectivity allows for real-time data viewing and control from anywhere, with alerts and updates sent over the network. The device can store up to ten groups of data for enhanced usability and efficiency.

Front view of the XY-SK120 module displaying input/output voltage, current, and power, along with key specifications.

Image: Front view of the XY-SK120 module displaying input/output voltage, current, and power, along with key specifications.

2. Setup

2.1 Wiring Instructions

Careful wiring is essential for safe and proper operation. Refer to the diagrams below for correct connections.

Internal wiring diagram and functional interfaces of the XY-SK120 module, showing input/output terminals, fan, capacitors, inductors, and communication ports.

Image: Internal wiring diagram and functional interfaces of the XY-SK120 module, showing input/output terminals, fan, capacitors, inductors, and communication ports.

  • Input Power: Connect your DC input power source to the IN+ (positive) and IN- (negative) terminals.
  • Output Load: Connect your load to the OUT+ (positive) and OUT- (negative) terminals.
  • External Temperature Probe: If using, connect the 10k NTC 3905B external temperature sensor to its designated interface.
  • Serial Communication: The serial communication interface allows connection to other modules or systems for control.
  • Optional Modules: The module supports connection to an XY-K485X module for 485 bus control or a WiFi module for APP and web-based networking control.

Important Safety Warning for Battery Charging:

This product does NOT have positive reverse connection protection for the battery. Reversing the positive and negative terminals of the battery will damage the device. Battery charging requires specific professional knowledge. Non-professionals are not allowed to charge directly to prevent fire and explosion.

Wiring diagram for MPPT solar charging with an external temperature probe connected to a battery and solar panel.

Image: Wiring diagram for MPPT solar charging with an external temperature probe connected to a battery and solar panel.

2.2 Initial Power-on

Once all connections are securely made, apply the input voltage. The device should power on and display the main user interface on the LCD screen.

3. Operating Instructions

3.1 Button Functions

Diagram illustrating the functions of each button (VSET, SW, ISET, Encoder, Power) on the XY-SK120 module's main UI.

Image: Diagram illustrating the functions of each button (VSET, SW, ISET, Encoder, Power) on the XY-SK120 module's main UI.

  • VSET Button:
    • Short Press: Set output voltage (CV).
    • Long Press: Enter or exit the data group UI.
  • SW Button:
    • Short Press: Switch between input and output voltage display, or shift selection during settings.
    • Long Press: Enter or exit the system settings UI.
  • ISET Button:
    • Short Press: Set output current (CC).
    • Long Press: Enter or exit the data group settings UI.
  • Encoder Button:
    • Short Press: Switch between displaying output power (W), capacity (Ah), energy (Wh), time (h), and temperature (°C) in rotation.
    • Long Press: Turn on/off the key lock.
  • Power Button:
    • Short Press: Turn on/off the power output.
    • Long Press: Reset the displayed capacity (Ah), energy (Wh), and time (h) values.

3.2 Setting Voltage and Current

Instructions for setting voltage and current on the XY-SK120 module, showing button presses and encoder rotation.

Image: Instructions for setting voltage and current on the XY-SK120 module, showing button presses and encoder rotation.

  1. On the main UI, briefly press the VSET button to set the voltage. The LCD will display "SET" in the lower row, and "CV" will flash, indicating the voltage setting position is selected and blinking.
  2. Briefly press the SW button or rotate the encoder to switch the voltage setting position (e.g., tens, units, decimals).
  3. Adjust the value by rotating the encoder.
  4. After setting is complete, briefly press the VSET button to exit and save.
  5. To set the current (CC), briefly press the ISET button and follow the same steps.

3.3 Quick Setting of Voltage or Current

  1. In the system parameter settings UI (see section 3.4), set the parameter FEr to CV for voltage or CC for current.
  2. Rotate the encoder on the main UI to enter the quick voltage or current setting UI.
  3. Rotate the encoder to quickly set the desired voltage or current.

3.4 Parameter Settings within Data Groups (Cd0-Cd9)

UI for setting parameters within data groups (Cd0-9, CV, CC, LVP, OVP, OCP) on the XY-SK120 module.

Image: UI for setting parameters within data groups (Cd0-9, CV, CC, LVP, OVP, OCP) on the XY-SK120 module.

  1. Press and hold the ISET button on the main interface to enter the settings menu.
  2. The first parameter is to select the data group Cd0-9.
  3. Briefly press VSET to select the next parameter, and briefly press ISET to select the previous parameter.
  4. Adjust values using the encoder.
  5. After completing the settings, press and hold the ISET, SW, or encoder button to exit the settings interface.
  6. Parameters available for setting in data groups include:
    • Cd0-Cd9: Select the data group (default is Cd0).
    • CV: Set the voltage.
    • CC: Set the current.
    • LVP: Set the input undervoltage protection value (default 5.5V).
    • OVP: Set the output overvoltage protection value (default 38V).
    • OCP: Set the output overcurrent protection value (default 6.2A).

3.5 System Parameter Settings

UI for setting system parameters (buzzer, brightness, temperature unit, quick adjust, device address, baud rate) on the XY-SK120 module.

Image: UI for setting system parameters (buzzer, brightness, temperature unit, quick adjust, device address, baud rate) on the XY-SK120 module.

  1. Press and hold the SW button on the main interface to enter the system settings menu.
  2. The first parameter is the buzzer setting (bEP).
  3. Briefly press VSET to select the next parameter, and briefly press ISET to select the previous parameter.
  4. Adjust values using the encoder.
  5. After completing the settings, press and hold the SW or encoder button to exit the settings interface.
  6. System parameters include:
    • bEP: Turn on/off the buzzer (default is on).
    • b-L: LCD brightness adjustment (default is brightest).
    • C-F: Celsius (°C) and Fahrenheit (°F) selection (default is °C).
    • FEr CU: Quick voltage or current adjustment (FET) (default is CV).
    • Add: Set the device address (default 001).
    • bAE: Set the device communication baud rate (default 115200).

3.6 Display Modes and Key Lock

Instructions for switching input/output display, checking various parameters (W, Ah, Wh, time, temp), and using the key lock function on the XY-SK120 module.

Image: Instructions for switching input/output display, checking various parameters (W, Ah, Wh, time, temp), and using the key lock function on the XY-SK120 module.

  • Input/Output Voltage Display: On the main UI, briefly press the SW button to switch between displaying input voltage (IN) and output voltage.
  • Checking Output Parameters: On the main UI, briefly press the encoder button to cycle through displaying output power (W), capacity (Ah), energy (Wh), time (h), and temperature (°C).
  • Key Lock: To prevent accidental misoperation, press and hold the encoder button for 2 seconds to lock the set voltage and current. A lock symbol will appear. Press and hold the encoder button for 2 seconds again to unlock.
Display modes for constant current (CC) and constant power (CW), and how set voltage and current are displayed when the power output is off.

Image: Display modes for constant current (CC) and constant power (CW), and how set voltage and current are displayed when the power output is off.

  • Constant Current/Power Display: The display indicates whether the module is operating in Constant Voltage (CV), Constant Current (CC), or Constant Power (CW) mode.
  • Power Off Display: When the power output is off, the set voltage and current values are displayed.

4. Features

  • LCD Display: Full-angle VA color LCD with a 38*29mm viewable area, large and rounded fonts for clear readability.
  • Protection Mechanisms: Equipped with comprehensive protections including anti-reverse connection, anti-backflow, input undervoltage (LVP), output over-voltage (OVP), output over-current (OCP), output over-power (OPP), over-temperature (OTP), over-time out (OHP), over-capacity (OAH), and over-energy (OEH).
  • MPPT Function: Supports Maximum Power Point Tracking (MPPT) for efficient solar charging.
  • Communication: Supports standard Modbus protocol for serial communication.
  • Network Control: Enables remote control via PC host computer software and mobile app (Android/iOS) using Sinilink cloud services. Features LAN real-time communication, external network access, cloud record, and email notifications.
  • Multi-Serial Port Host Software: The software supports multi-serial port communication, allowing up to 247 devices to be connected to a single serial port, and thousands in a clustered environment. It also supports batch control of all devices and administrative accounts for secure management.
  • Hardware Design: Features an integrated molded frosted panel, high-quality aluminum alloy knob, built-in buzzer for alerts, upgraded plug-and-pull terminals for easy disassembly and replacement, an intelligent temperature-controlled fan with large-area ventilation heat sinks, high-quality solid-state capacitors, and dual inductance design with high-power, high-temperature resistant FeSiAl magnetic ring inductors.
Diagram illustrating network control capabilities of the XY-SK120 module via PC, mobile app, and cloud services.

Image: Diagram illustrating network control capabilities of the XY-SK120 module via PC, mobile app, and cloud services.

Product details showing the built-in buzzer for key prompts and alarms, and upgraded plug-and-pull terminals for easy maintenance.

Image: Product details showing the built-in buzzer for key prompts and alarms, and upgraded plug-and-pull terminals for easy maintenance.

5. Specifications

Table of product parameters and protection mechanisms for the XY-SK120 module.

Image: Table of product parameters and protection mechanisms for the XY-SK120 module.

ParameterValueParameterValue
Product NameDC buck-boost power supplyModelXY-SK120
Input Voltage6.0-36VOutput Voltage0-36V
Output Current0-6.000AAccuracy of Voltage±0.5%+1 word
Power Output120WAccuracy of Current±0.5%+3 words
Resolution of Voltage0.01VResolution of Current0.001A
Storage Data Group10 groupsSoft StartYES
Screen SizeOver 1.8-inch LCD (38*29mm)MPPT FunctionSupport Solar Charging
BuzzerYESEfficiency of ConversionAbout 88%
Number of ButtonsFiveProduct Size79*50*43mm
Product Weight108gPackage Size104*70*52mm
Package Weight127g

Protection Mechanisms:

ProtectionDescription / Default Value
Anti-reverse ConnectionYES
Output Backflow ProtectionYES
Input Undervoltage (LVP)Adjustable 5.5-36V (Default 5.5V)
Output Over-voltage (OVP)Adjustable 0-38V (Default 38V)
Output Over-current (OCP)Adjustable 0-6.2A (Default 6.2A)
Output Over-power (OPP)Adjustable 0-150W (Default 125W)
Over-temperature (OTP)Adjustable 0-110°C (Default 95°C)
Timeout (OHP)Adjustable 0-100H (Default OFF)
Over-capacity (OAH)Adjustable 0-9999AH (Default OFF)
Over-energy (OEH)Adjustable 0-4200KWH (Default OFF)
Product dimensions and recommended opening size for installation of the XY-SK120 module.

Image: Product dimensions and recommended opening size for installation of the XY-SK120 module.

6. Maintenance

6.1 Firmware Upgrade

The product supports firmware upgrades to obtain new functions. At present, it primarily supports firmware upgrades through a dedicated WiFi module. Future updates may allow upgrades through multi-serial port host computer software.

Firmware upgrade screen of the XY-SK120 module, showing version number, steps, status, and progress, with a warning not to power off during the process.

Image: Firmware upgrade screen of the XY-SK120 module, showing version number, steps, status, and progress, with a warning not to power off during the process.

Note: Do not power off during the product upgrade process. If the product upgrade fails, you can press and hold the power button to power on the product and force it into the upgrade mode.

6.2 General Care

  • Keep the device clean and free from dust and debris.
  • Avoid exposing the module to extreme temperatures, humidity, or corrosive environments.
  • Ensure proper ventilation, especially when operating at higher power outputs, to prevent overheating.
  • The upgraded plug-and-pull terminals are designed for easy disassembly and replacement, simplifying maintenance of connections.

7. Troubleshooting

  • No Power/Display: Check input voltage connections and ensure they are within the specified range (6.0-36V). Verify all wiring is correct and secure.
  • No Output: Ensure the power output is enabled by briefly pressing the Power Button. Check if any protection mechanisms (OVP, OCP, OPP, OTP) have been triggered.
  • Protection Triggered: If the output cuts off, check the display for any active protection indicators. Review and adjust the corresponding protection limits (OVP, OCP, OPP, OTP, OHP, OAH, OEH) in the data group settings if necessary.
  • Display Issues: If the LCD is too dim or bright, adjust the brightness setting (b-L) in the system parameters.
  • Firmware Upgrade Failure: If an upgrade fails, press and hold the power button to force the product into upgrade mode and retry the process.
  • Incorrect Readings: Ensure the external temperature probe is correctly connected if temperature readings are inaccurate.
  • Communication Issues: Verify the device address (Add) and baud rate (bAE) settings in the system parameters match your communication setup.

8. User Tips

  • Maximize Power Output: While rated at 120W, the module can achieve up to 150W with software support. For optimal performance and higher power output (130W-150W), ensure excellent cooling conditions.
  • Battery Charging Safety: Always exercise extreme caution when charging batteries. Due to the lack of reverse connection protection for batteries, incorrect polarity can damage the device. It is highly recommended that only individuals with professional knowledge handle battery charging to prevent hazards.
  • Easy Terminal Maintenance: The upgraded plug-and-pull terminals simplify wiring and maintenance. If a terminal connection becomes loose or needs replacement, it can be easily disassembled and reassembled.
  • Remote Monitoring: Utilize the mobile app or PC software with the WiFi module for convenient remote monitoring and control of your power supply, especially useful for long-term projects or inaccessible setups.

9. Warranty and Support

For any technical assistance, warranty claims, or support inquiries, please contact the seller or manufacturer directly. Ensure you have your product model (XY-SK120) and any relevant purchase information available when seeking support.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.