1. Product Overview
The RD6030W is a digital control DC adjustable step-down voltage bench power supply, offering high current output up to 30A and a maximum power of 1800W. It features USB and WiFi communication for remote control and monitoring, a 2.4-inch color HD display, and multiple protection functions to ensure safe and stable operation.

Figure 1: RD6030W Digital Control Power Supply with 30A High Current Output.
Video 1: Overview of RD6030W features including higher range, display styles, mobile app, and PC software control.
2. Safety Information
- Ensure proper ventilation during operation to prevent overheating.
- Do not exceed the specified input voltage range (7-70.00V) to avoid damage.
- Always use appropriate wiring for high current applications. For 30A output, it is recommended to use copper cable lugs with 4 square millimeter or 11AWG wire.
- The product can withstand input over-voltage of 100V for up to 1 second. However, continuous over-voltage should be avoided.
- Turn off the AC switch when the product is not in use.
3. Setup and Connections
3.1 Physical Dimensions
The product dimensions are 167mm (length) x 81mm (width) x 69mm (height). The painted open size for mounting is 74.6mm x 160mm. Different thickness and hardness materials may require slightly different open sizes. Testing is recommended before batch punching.

Figure 2: Product Dimensions and Mounting Information.
3.2 Internal Components and Connections
The RD6030W features a well-designed internal layout for various connections and components:

Figure 3: Rich Configuration and Internal Connections.
- Input Negative/Positive: Main power input terminals.
- 1032 40A Fuse: Provides overcurrent protection.
- External Fan Socket: For connecting an external cooling fan.
- Temperature Sensor Socket: For connecting an external temperature sensor.
- Communication Socket: For USB communication.
- Wi-Fi Communication Board: (Only for RD6030-W model) Enables wireless control.
- Clock Battery Slot: Requires a CR1220 battery (not included) for real-time clock functionality.
Caution: Do not connect non-original accessories to the temperature sensor/fan/communication interface on the board to avoid device damage.
4. Operating Instructions
4.1 Basic Operation
The RD6030W features a user-friendly interface with a 2.4-inch color HD display and physical buttons for setting voltage, current, and other parameters. The rotary encoder allows for precise adjustments.
4.2 Display Styles
The device supports multiple display styles: Classic, Detailed, and Curve. The system defaults to the Classic style. Click the 'SHIFT' button to cycle through the display styles.

Figure 4: Available Display Styles.
4.3 PC Software Control
The RD6030W can be monitored and controlled via PC software (supports Windows 7 and above). Connect the device to your computer using a USB cable. The software provides a friendly interface for setting parameters, viewing output graphs, and managing data.

Figure 5: PC Software Interface for Easy Control.
4.4 Mobile App Control (RD6030-W Only)
For the RD6030-W model, a mobile application (Android and iOS) is available for Bluetooth control. This allows for convenient remote operation and monitoring from your smartphone.

Figure 6: Mobile App Interface for Remote Control.
Note: Compatibility with mobile phones may vary. It is recommended to test the app before purchasing. For Android, download the app from the accessory pack. For Apple iOS (10.0-13.4), search for "ruideng" to download the app.
5. Maintenance
5.1 Firmware Updates
Firmware can be upgraded to optimize the product experience and ensure it is constantly updated and optimized. If the device cannot start normally, you may need to enter Boot mode to upgrade the firmware.

Figure 7: Firmware Update Process.
5.2 Cleaning
Keep the device clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
6. Troubleshooting
6.1 Noise from 1500W PSU
When the switching power supply is unloaded, a high-frequency noise may be audible. This is due to the PWM control chip skipping some control cycles to reduce power consumption, which can lower the working frequency below 20KHz. The intensity of this noise can vary slightly between units due to manufacturing variations in the transformer. This is considered a normal phenomenon. It is recommended to turn off the AC switch when the product is not in use.
6.2 Fan Noise
A loud sound from the fan may occur, especially when the ambient temperature is high, even if the unit is unloaded. This is also a normal phenomenon as the fan activates to maintain optimal operating temperature. The cooling fan starts when the output current exceeds 8A or the system temperature exceeds 45℃.
6.3 Power Output Limitations with 1500W PSU
If using a 1500W Power Supply Unit (PSU):
- Under 220V AC input, the 1500W PSU can allow the RD6030 to output a maximum of 1440W.
- Under 110V AC input, the 1500W PSU can only allow the RD6030 to output a maximum of 1140W.
Please consider these limitations when selecting your PSU and operating the device.
6.4 Over-Voltage Protection
The device includes input over-voltage protection. An over-voltage warning will prompt if the input voltage exceeds 72V. Product power cutoff protection activates when the input voltage exceeds 75V. The product can withstand input over-voltage of 100V for up to 1 second.

Figure 8: Input Over-Voltage Protection Warning.

Figure 9: Product Power Cutoff Protection.
7. Specifications
| Parameter | Value |
|---|---|
| Model | RD6030-W |
| Input Voltage Range | 7-70.00V |
| Output Voltage Range | 0-60.00V |
| Output Current Range | 0-30.00A |
| Output Power Range | 0-1800W |
| Input Voltage Measurement Resolution | 0.01V |
| Output Voltage Resolution | 0.01V |
| Output Current Resolution | 0.01A |
| Battery Voltage Resolution | 0.01V |
| Input Voltage Measurement Accuracy | ±(1%+5 digits) |
| Output Voltage Accuracy | ±(0.3%+3 digits) |
| Output Current Accuracy | ±(0.5%+5 digits) |
| Battery Voltage Measurement Accuracy | ±(0.5%+3 digits) |
| Default Cutoff Current Value (Charging) | 100mA |
| Output Ripple Typical | 50mV@15A, 90mV@30A VPP |
| Working Temperature Range | -10℃~40℃ |
| External Sensor Temperature Detection Range | -10℃~100℃ / 0℉~200℉ |
| External Sensor Temperature Detection Accuracy | ±3℃ / ±6℉ |
| Constant Voltage Mode Response Time | 2ms (0.1A-5A Load) |
| Constant Voltage Mode Load Regulation | ±(0.1%+2 digits) |
| Constant Current Mode Load Regulation | ±(0.1%+3 digits) |
| Capacity Measurement Range | 0-9999.99Ah |
| Energy Measurement Range | 0-9999.99W |
| Capacity and Energy Statistical Error | ±2% |
| Buck Working Mode | (Input Voltage ÷ 1.1) - 1 |
| Over Temperature Protection | System temperature > 80℃ |
| Screen Brightness Setting | 0-5 (6 levels in total) |
| Screen | 2.4 inch color HD display |
| Weight (with package) | About 0.74kg |
| Product Dimension | 167*81*69mm |
| Cooling Fan Start Condition | Output current > 8A or System temperature > 45℃ |
8. User Tips
- High Current Applications: For optimal performance and safety when drawing 30A, ensure you use robust copper cable lugs with 4 square millimeter or 11AWG wire.
- Remote Control: Utilize the PC software or mobile app (RD6030-W only) for convenient remote monitoring and control, especially for long-duration tests or when precise adjustments are needed from a distance.
- Firmware Updates: Regularly check for and apply firmware updates to benefit from performance optimizations and new features.
- Display Customization: Experiment with the different display styles (Classic, Detailed, Curve) and color customization options to find the most comfortable and informative view for your tasks.
- Monitoring Protections: Pay attention to the various protection indicators (e.g., OVP, OCP) on the display to ensure your connected devices are safe.
9. Warranty and Support