1. Product Overview

The SUMRY Hybrid Solar Inverter is a multi-function inverter/charger, combining the functions of an inverter, MPPT solar charger, and battery charger to offer uninterruptible power support in a portable size. It features a pure sine wave output and is designed for off-grid applications.

SUMRY 6200W 48V Hybrid Solar Inverter front view with key features

Figure 1: Front view of the SUMRY Hybrid Solar Inverter highlighting key features.

Key Features:

  • Pure sine wave output.
  • Programmable supply priority for PV, battery, or Grid.
  • High PV input voltage range (55~450VDC).
  • Built-in Max 110A (for 6.2KW models) MPPT solar charge controller.
  • Compatible with lithium-ion batteries.
  • Supports BMS communication with lithium batteries.
  • Smart battery charge design to optimize battery life.
  • Overload, high temperature, and inverter output short circuit protection.
  • Cold start function.
  • Intelligent fan speed adjustment.
  • WIFI & GPRS available for iOS and Android (optional).
Detailed features of the MPPT Hybrid Solar Inverter

Figure 2: Detailed features of the MPPT Hybrid Solar Inverter.

2. Setup and Installation

2.1 Unboxing

Carefully unpack the inverter and inspect it for any damage. Ensure all components are present according to the packing list.

Video 1: Product unboxing and demonstration of charging various devices.

2.2 Mounting the Unit

Consider the following points before selecting where to install:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level in order to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

CAUTION: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Diagram showing mounting clearances for the inverter

Figure 3: Mounting instructions with recommended clearances.

2.3 Wiring and Connections

Ensure all connections are secure and correctly polarized. Refer to the system diagram for proper wiring.

Rear view of the inverter showing AC input, AC output, PV input, and battery terminals

Figure 4: Rear view of the inverter with connection terminals.

Battery Connection:

Connect all battery packs as shown in the chart below. Ensure correct voltage for your model (e.g., 1.8KW model supports 12VDC system, 3KW model supports 24VDC system).

Battery connection diagram for 12VDC and 24VDC systems

Figure 5: Battery connection diagram.

System Diagram:

The inverter can power loads from PV energy, the grid, or batteries. The diagram illustrates operation with and without battery connection, and when solar power and AC power are not available.

System diagram showing inverter operation with and without battery connected

Figure 6: System diagram for various operating conditions.

3. Operating the Inverter

3.1 LCD Display and Function Keys

The LCD display provides real-time information about the inverter's status, input/output, and settings. Use the function keys (ESC, UP, DOWN, ENTER) to navigate menus and confirm selections.

LCD display and function keys with descriptions

Figure 7: Operation and Display Panel details.

LCD Function Description:

No.SymbolDescription
1PVPV input
2ACAC input
3INPUTBATTEMPInput voltage, input frequency, PV voltage, battery voltage, charger current
48.8Setting programs
58.8Flashing with warning code / Lighting with fault code
6OUTPUTBATTLOADOutput voltage, output frequency, load percent, load in VA, load in watt and discharging current
7Load level
8DC/AC inverter circuit is working
9Battery level
10Utility charger circuit is working
11Unit connects to the PV panel
12Unit connects to the mains
13Load is supplied by utility power
14Unit alarm is disabled
15Overload

Table 1: LCD Function Description.

LED Indicators:

LED IndicatorColorMessages
AC / INVGreenSolid On: Output is powered by utility in Line mode.
Flashing: Output is powered by battery or PV in battery mode.
CHGGreenSolid On: Battery is fully charged.
Flashing: Battery is charging.
FAULTRedSolid On: Fault occurs in the inverter.
Flashing: Warning condition occurs in the inverter.

Table 2: LED Indicator Messages.

3.2 WIFI Monitoring (Optional)

The inverter supports WIFI and GPRS monitoring via the SmartESS app, available for both iOS and Android devices. This allows for remote monitoring and control of your solar system.

WIFI monitoring module and QR codes for SmartESS app download

Figure 8: WIFI Monitoring setup with app QR codes.

4. Maintenance

Regular maintenance ensures the longevity and optimal performance of your SUMRY Hybrid Solar Inverter.

  • Cleaning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and heat dissipation. Use a soft, dry cloth for cleaning the exterior.
  • Connections: Periodically check all electrical connections (PV, battery, AC input/output) to ensure they are tight and free from corrosion.
  • Battery Health: The inverter features a smart battery charge design to optimize battery life. However, it is recommended to monitor battery health and capacity regularly, especially for lead-acid batteries.
  • Firmware Updates: If using the optional WIFI module, check for available firmware updates through the SmartESS app to ensure the inverter operates with the latest features and improvements.

5. Troubleshooting

This section provides guidance on common issues. For more complex problems, contact customer support.

Common Issues and Solutions:

  • Fault Indicator (Red Solid On/Flashing): A solid red light indicates a fault, while flashing indicates a warning. Refer to the LCD display for specific error codes and consult the detailed manual (if available) or customer support. Common faults include:
    • Overload Protection: Reduce the connected load.
    • Overheating Protection: Ensure adequate ventilation around the inverter. Check for blocked vents or high ambient temperatures.
    • High/Low Voltage Protection: Verify input and battery voltages are within the specified operating range.
    • Short Circuit Protection: Disconnect all loads and check for short circuits in the wiring.
    • Overcurrent Protection: Reduce the current draw from the inverter.
    • Anti-Reverse Protection: Ensure battery polarity is correct.
    • Power Failure Protection: Check AC input and battery connections.
  • No Output Power: Check AC input, battery connection, PV input, and ensure the inverter is turned on. Verify circuit breakers are not tripped.
  • Battery Not Charging: Check PV input, solar panel connections, and battery connections. Ensure the MPPT solar charger is functioning correctly (check CHG LED indicator).

6. Specifications

The following table outlines the technical specifications for various models in the SUMRY SP series, including the 6200W model.

Product parameters table for SUMRY SP series inverters

Figure 9: Product parameters for SUMRY SP series inverters.

ParameterSP-2200SP-3200SP-4200SP-7000 (6200W Model)
Rated Power2200VA/1800W3200VA/3000W4200VA/3800W7000VA/6200W
INPUT
Voltage230VAC
Selectable Voltage Range170-280VAC (for personal computers)
90-280VAC (for home appliances)
Frequency Range50Hz/60Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt.Mode)230VAC±5%
Surge Power4400VA6400VA8000VA14000VA
Transfer Time10ms (for personal computers)
20ms (for home appliances)
Wave formPure Sine Wave
BATTERY & AC CHARGER
Battery Voltage12VDC24VDC24VDC48VDC
Floating Charge Voltage13.5VDC27VDC27VDC54VDC
Overcharge Protection15.5VDC31VDC31VDC61VDC
Maximum charge current60A80A110A110A
SOLAR CHARGER
MAX.PV Array Power2000W3000W6000W6000W
MPPT Range@Operating Voltage55-450VDC
Maximum PV Array Open Circuit Voltage450VDC
Maximum Charging Current80A110A
Maximum Efficiency98%
PHYSICAL
Dimension D*W*H(mm)405*286*98mm405*286*98mm423*290*100mm423*310*106mm
Net Weight (kgs)4.5kg5.0kg7.0kg8.0kg
Communication InterfaceRS232/RS485 (Standard), GPRS/WIFI (Optional)
OPERATING ENVIRONMENT
Humidity5% to 95% Relative Humidity (Non-condensing)
Operating Temperature-10°C to 55°C
Storage Temperature-15°C to 60°C

Additional Specifications:

  • Output Power: 1 - 200 KW
  • Output Type: SINGLE
  • Output Frequency: 50/60Hz
  • Is Smart Device: Yes
  • Origin: Mainland China
  • Certification: CE, RoHS

7. User Tips

  • Power Rating: Always ensure the inverter's power rating is higher than the appliance you intend to power. It is recommended to purchase a model with at least 10% to 20% more capacity than your maximum expected load.
  • Inductive Loads: For running inductive loads (e.g., motors, refrigerators) for extended periods, a pure sine wave inverter like this model is essential for optimal performance and to prevent damage to appliances.
  • System Compatibility: This inverter is designed for off-grid applications, providing power from PV, battery, or grid when available.

8. Warranty and Support

The SUMRY Hybrid Solar Inverter comes with a 1-year warranty. For technical support, troubleshooting assistance beyond this manual, or warranty claims, please contact the SUMRY Official Store or your authorized dealer.