1. Introduction
The KUAIQU 13MP VGA Video Microscope Camera (Model: QTG S1 231T-130) is a high-definition digital microscope system designed for detailed observation and analysis. It features a 13MP VGA camera, a 1-130X continuous zoom C-mount lens, and an adjustable LED light source. This microscope is particularly suitable for microelectronics, phone repair, jewelry inspection, industrial quality control, and various biological applications.
The system utilizes unique techniques for eliminating stray light and achieving a large depth of field, offering clarity, strong three-dimensionality, long working distance, and a wide field of view. When paired with high-definition color CCDs and displays, it provides excellent visual results.
Optional accessories include 0.5X and 2X series additional large objective lenses, and 0.35X, 0.5X, 1X series photographic eyepieces to meet diverse magnification requirements. The bracket system can be configured as a column type, folding type, or universal bracket, depending on user needs.
2. Safety Precautions
2.1. Do Not Disassemble
Improper disassembly can easily damage the instrument. Do not disassemble any parts other than the detachable components mentioned in this manual. If any malfunction is found, seek experienced professional repair personnel or contact the manufacturer directly.
2.2. Check the Voltage
- The microscope camera and light source are marked with their rated input voltage. Ensure the local power supply voltage matches this rating. Using the microscope under non-rated voltage conditions will cause serious damage.
- The power socket must be well grounded.
2.3. Anti-Scalding and Fire Prevention
- During operation, the light source can become very hot. Be careful not to touch it to prevent burns.
- Replace the light source only after the bulb has cooled sufficiently.
- Do not place flammable objects near the light source to avoid fire.
2.4. Handling and Placement
- Before transporting the microscope, ensure the power switch is turned off.
- Working environment requirements: Room temperature: 0°C ~ 40°C, Maximum relative humidity: 85%.
- Avoid using the microscope under direct sunlight.
- Avoid placing the microscope in a dusty environment. When not in use, cover it with a dust cover.
- The microscope should be placed on a flat surface without vibration.
3. Product Components and Structure
The microscope system typically includes a VGA camera, a C-mount zoom lens, an adjustable LED ring light, a power adapter, and a stand. The specific components may vary based on the selected package.
3.1. VGA Camera Description
The camera features a 13MP pixel array and supports VGA video output. Key specifications include:
- Overall Dimension: 75*50*50mm
- Video Interface: VGA
- Lens Mount: CS
- Working Voltage: 12V
- Working Current: 150mA
- Optical Format: 1/3"
- Pixel Size: 2.8um*2.8um
- TV Lines: 1200TVLine
- FPS of Max Image: 30FPS
- Scanning Mode: Progressive
- Shutter Mode: Electronic shutter
- Dynamic Range: 65dB
- S/N Ratio: 45dB
- OSD Language: English/Chinese (and other languages as noted in user reviews)
- AWB Mode: One-time white balance / manual / auto
- HDR: Adjustable
- Cross Line: Support 8 colors / line width adjustable
- B/W: Allowed
- Negative: Allowed
- Mirror Flip: Support left / right / up / down
- Freeze: Allowed
- Compare: Allowed
- Manual Settings: Brightness, contrast, sharpness, saturation adjustable
- Output Display Resolution: VGA: 1920*1080 / 1600*900 / 1440*900 / 1366*768 / 1280*1024 / 1280*720 / 1024*768 / 800*600 (Supports various displays on the market)
3.2. 1X-130X Zoom C-mount Lens
- Work Distance: 40mm-220mm
- Zoom Ratios: 1:17
- Magnification Power: 0.1 - 1.3X (approximately 1 - 130X on the display)
- View Field of Max Multiple: 8mm*4.5mm
- View Field of Min Multiple: 40mm*33mm
- Size: 115mm(L) * 40mm(DIA)
- Weight: 210g
3.3. LED Light Source
The LED light source provides adjustable brightness for optimal illumination of the specimen. It connects to the camera via the LED OUT port.
- Input Voltage: 220V/50Hz or 110V/60Hz (check your local power supply)
- Controls: Main switch at the rear for ON/OFF, side knob for brightness adjustment.
3.4. Bracket Systems
Various bracket types are available to suit different applications and user preferences. These include large base, mid base, small base, and folding bracket sets. Each bracket type provides stability and adjustability for precise positioning of the microscope.
3.5. Instrument Completeness (Typical Configurations)
| Name | Desktop set | Folding bracket set | Notes |
|---|---|---|---|
| Floor | √ | The actual selection and matching set introduction shall prevail | |
| Column | √ | ||
| Lens holder | √ | ||
| Folding stand | √ | ||
| Camera lens | √ | √ | |
| CCD camera | √ | √ | |
| Ring light | √ | √ | |
| Power cord | √ | √ |
4. Setup and Installation
To fully understand the functions and expansion of this instrument and the connection and installation of various parts, please refer to the relevant "Color TV User Manual" and "CCD Camera User Manual" if provided, as this manual focuses on the microscope system itself.
4.1. Base Installation (Example: Large Base Set)
- Take out the bracket and various components from the packaging box.
- Fix the pillar to the base using connecting screws.
- Insert the limit ring into the pillar and tighten it.
- Insert the focusing mechanism into the pillar to the appropriate position, then tighten the hand wheel to prevent it from sliding down.
- Place the variable magnification main objective lens (9) into the inner hole of the focusing mechanism (2).
- Insert the photographic eyepiece lens (10) (most are pre-installed).
- If an optional accessory objective lens (7) is used, screw it into the variable magnification main objective lens (9).
- Screw the CCD camera (11) into the eyepiece (10).
- Insert the CCD power adapter and video signal cable into the CCD camera (11). Connect the other end of the signal cable to the video input of your monitor. (Note: Some cameras with VGA interfaces do not come with signal cables; users need to provide their own VGA cables.)
- Insert the circular LED light into the groove at the bottom of the main lens (9), and tighten the three directional screws in equal proportions to secure it.
4.2. Folding Bracket Installation
- Take out the bracket and its components from the packaging box.
- Clamp the clamp (2) on the edge of the desktop.
- Rotate the fixing device (1) to secure it to the desktop.
- Insert the unscrewed end of the bracket into the clamp hole.
- Rotate the fixture to fix the bracket.
- After checking the stability of the bracket, install the CCD camera (6). Screw holes on the side of the camera allow direct rotation and fixing to the front end of the bracket.
- After tightening, adjust the camera orientation angle by rotating the angle fastener (4).
- After fixing the camera, remove the protective cover of the matching lens and rotate the threaded end to the bottom of the CCD camera.
- Insert the circular LED light into the groove at the bottom of the main lens (7), and tighten the three directional screws in equal proportion to secure it.
Refer to the specific bracket diagrams (Figures 6-10) for visual guidance during installation.
4.3. Initial Power-Up and Connection Check
- Ensure all connections (power, video) are secure.
- Verify that the input voltage for the CCD camera, monitor, and microscope matches the power grid voltage.
- Connect the power supply. The power socket must have a grounding terminal.
5. Operation
5.1. Focusing
Rotate the focusing hand wheel (4) or adjust the height of the focusing mechanism (2) (according to the working distance W.D. of the selected additional large objective lens) to achieve focus. This is often used in conjunction with the limit ring.
5.2. Adjusting Magnification
The rotating sleeve (8) in the variable magnification main lens (9) allows for continuously changing magnification. The magnification of the objective lens varies from 0.7X to 4.5X. Lower magnification provides a larger field of view, which is recommended for initially finding the target before increasing magnification for detailed observation.
Each component is factory-adjusted to ensure synchronization of continuous magnification observation.
5.3. Using LED Lights
When using LED lights for illumination, first place the small object to be observed on the stage and adjust the brightness of the light as needed using the side knob on the camera.
5.4. Adjusting for Blurry Images
If the image is blurry, adjust the focus using the rotating sleeve (8) in the height rotating main lens to achieve a clear display effect.
5.5. OSD Menu Navigation
Use the MENU buttons on the camera (Figure 2) to navigate the On-Screen Display (OSD) menu (Figure 3). This allows adjustment of various image parameters such as white balance, HDR, brightness, contrast, sharpness, resolution, and more. The menu supports multiple languages including English and Chinese.
6. Maintenance and Upkeep
6.1. Storage
When the instrument is not in use, it is recommended to wipe it clean first, then cover it with a dust cover and store it in a dry place.
6.2. Cleaning Lenses
- Do not touch optical components with your bare hands.
- It is best to use a soft brush or dust cloth to remove dust.
- Stubborn stains, fingerprints, grease, etc., can be gently wiped off with a clean soft cotton cloth or lens paper dipped in a mixture of anhydrous ethanol and ether.
7. Troubleshooting
- No Image / Incorrect Display: If the microscope is not displaying an image or the image is incorrect, check the monitor's input settings. The default output settings of the microscope camera might be set very high, and some monitors may not be able to display the image correctly until these settings are adjusted via the OSD menu.
- Blurry Image: Adjust the focusing hand wheel and the rotating sleeve on the main lens. Ensure the working distance is appropriate for the selected magnification.
- Microscope Gets Hot: It is normal for the LED light source to generate heat during operation. Ensure proper ventilation around the device. If the camera itself becomes excessively hot, discontinue use and contact support.
- Expected Software but None Provided: This microscope camera outputs directly to a VGA monitor and does not typically require additional software for basic operation. If you require image capture or advanced features, you may need a separate VGA capture card and associated software (not included).
8. Specifications
8.1. VGA Camera Specifications
| Feature | Specification |
|---|---|
| Pixel Array | 13MP |
| Overall Dimension | 75*50*50mm |
| Video Interface | VGA |
| Lens Mount | CS |
| Working Voltage | 12V |
| Working Current | 150mA |
| Optical Format | 1/3" |
| Pixel Size | 2.8um*2.8um |
| TV Lines | 1200TVLine |
| FPS of Max Image | 30FPS |
| Scanning Mode | Progressive |
| Shutter Mode | Electronic shutter |
| Dynamic Range | 65dB |
| S/N Ratio | 45dB |
| OSD Language | English/Chinese (Multi-language support) |
| Output Display Resolution | VGA: 1920*1080, 1600*900, 1440*900, 1366*768, 1280*1024, 1280*720, 1024*768, 800*600 |
8.2. 1X-130X Zoom C-mount Lens Specifications
| Feature | Specification |
|---|---|
| Work Distance | 40mm-220mm |
| Zoom Ratios | 1:17 |
| Magnification Power | 0.1 - 1.3X (approx. 1 - 130X on display) |
| View Field (Max Multiple) | 8mm*4.5mm |
| View Field (Min Multiple) | 40mm*33mm |
| Size | 115mm(L) * 40mm(DIA) |
| Weight | 210g |
8.3. Common Lens Specifications (from PDF)
| Name | Magnification Factor | Working Distance | Installation Ring Diameter |
|---|---|---|---|
| 180X long lens | 1-180X | 5-10cm | Φ50mm |
| 130X lens | 1-130X | 5-15cm | Φ42mm |
| 150X with ring lens | 1-150X | 5-100cm | Φ50mm (Some models are paired with Φ42mm) |
| 150X without ring lens | 1-150 | 5-100cm | Paired with bracket style |
8.4. Optical Magnification (from PDF)
| Auxiliary Objective Lens | Photographic Eyepiece | Working Distance (mm) | ||
|---|---|---|---|---|
| 0.35X | 0.5X | 1X | ||
| 0.5X | 0.12~0.19X | 0.18~1.13X | 0.35~2.25X | 180 |
| No additional large eyepiece | 0.25~1.58X | 0.35~2.25X | 0.70~4.50X | 95 |
| 2X | 0.49~3.15X | 0.70~4.5X | 1.40~9.00X | 32 |
8.5. Digital Amplification Factor (from PDF)
| CCD Camera Specifications | Monitor (TV) Specifications | |||||
|---|---|---|---|---|---|---|
| 14" | 15" | 17" | 21" | 25" | 29" | |
| 1/3" | 59.2X | 63.5X | 72.0X | 88.5X | 105.8X | 122.8X |
| 1/2" | 44.5X | 47.6X | 54.0X | 66.7X | 79.4X | 92.1X |
| 2/3" | 32.3X | 34.6X | 39.3X | 48.5X | 57.7X | 67.0X |
8.6. Effective Diagonal Size of CCD Camera Target Surface (from PDF)
| CCD Camera Specifications | 1/3" | 1/2" | 2/3" |
|---|---|---|---|
| CCD Effective Diagonal Size | 6mm | 8mm | 11mm |
9. User Tips
- Monitor Compatibility: If the image is not displaying correctly, especially after initial setup, check your monitor's input settings. The microscope's default output settings might be too high for some monitors. Adjust the resolution via the OSD menu if necessary.
- Alternative Stands: The microscope lens is designed to be compatible with various stands. Users have successfully adapted it to existing stands (e.g., from magnifying glasses) or microphone arms for flexible positioning. Ensure any alternative stand provides stable support.
- Multi-Language OSD: The On-Screen Display (OSD) menu supports multiple languages, including English, Chinese, Ukrainian, and Russian, making it easier to navigate and adjust settings.
- No Software Needed for Basic Use: This microscope camera is designed for direct output to a VGA monitor and typically does not require additional software for basic viewing.
10. Warranty and Support
This product comes with a 12-month warranty.
If you encounter any issues or are not satisfied with the product, please contact the seller or manufacturer directly. Provide evidence of the problem to facilitate a return, resend, or warranty claim.
For detailed information on specific bracket types or advanced features, refer to the full user manual (PDF) available for download:
Download Full User Manual (PDF)
You can also scan the QR code below to download the application or access additional resources: