VaneAims TC3 Series

Contents

VaneAims TC3 Series Thermoregulator Temperature Controller

Models: TC3-S, TC3-H, TC3-M

1. Introduction

The VaneAims TC3 series temperature controller is a versatile device designed for precise temperature regulation in various applications. It operates with a supply voltage of 85-265VAC 50/60Hz and features a dual output system comprising an electromagnetic relay and a Solid State Relay (SSR). This controller supports universal input types, allowing connection of various thermocouples and RTD sensors such as K, J, PT100, E, B, S, N, R, T, and CU50.

Front view of VaneAims TC3-S, TC3-H, and TC3-M temperature controllers
Figure 1: VaneAims TC3 Series Temperature Controllers (TC3-S, TC3-H, TC3-M)

2. Product Overview

The TC3 series offers high precision and stable performance, making it suitable for industrial ovens, mobile phone separators, greenhouse planting, and other temperature-sensitive environments. Key features include:

  • Intelligent PID Control: Ensures accurate and stable real-time temperature monitoring.
  • Dual Output: Equipped with both electromagnetic relay and SSR outputs for flexible control.
  • Universal Input: Compatible with a wide range of thermocouples (K, J, E, B, S, N, R, T) and RTD sensors (PT100, CU50).
  • Clear Display: Features a 3-digital display and LED indicators for easy monitoring of measured value, set value, alarm, and output status.
  • Compact Design: Available in various sizes (TC3-S: 48x48mm, TC3-H: 48x96mm, TC3-M: 72x72mm) for easy integration.
Product advantages and application examples including industrial oven, mobile phone separator, and greenhouse planting
Figure 2: Product Advantages and Typical Applications

3. Specifications

Parameter Value
Product ModelTC3 series
Supply VoltageAC85-265V 50/60Hz
Measurement Precision±0.5%FS
Temperature Measurement Range0-999℃ [32-1830.2℉]
Input typesK, E, J, B, S, N, R, T, PT100, CU50 Available
Output typesElectromagnetic relay + SSR
Control MethodON/OFF Position control, PID control
Sampling period100ms
Indication method3-digital display and LED indication
Relay OutputRelay contact output 250VAC 5A 1NO1NC
SSR OutputSSR12VDC±2V Below 20mA
Dielectric strength2000VAC 50/60Hz for 1min. (between all terminals and case)
Memory retentionApprox.10years (non-volatile semiconductor memory type)
Ambient temp.-5~40℃ storage: -10~50℃
Ambient humi.35%~85%RH storage: 35~85%RH
Alarm Quantity1pcs

Dimensions

Detailed dimensions for TC3-S, TC3-H, and TC3-M models, showing front panel and cut-out sizes
Figure 3: Product Dimensions for TC3-S, TC3-H, and TC3-M

4. Installation and Wiring

Proper installation and wiring are crucial for the safe and effective operation of your temperature controller. Refer to the diagrams below for specific wiring connections for each model. Always ensure power is disconnected before performing any wiring.

Wiring Diagram for TC3-S

Wiring diagram for TC3-S model, showing connections for power, sensor, relay output, SSR output, and alarm
Figure 4: TC3-S Wiring Diagram and Dimensions

Wiring Diagram for TC3-M

Wiring diagram for TC3-M model, showing connections for power, sensor, relay output, SSR output, and alarm
Figure 5: TC3-M Wiring Diagram and Dimensions

General Wiring Principles:

  • Power Source (AC85-265V 50/60Hz): Connect to terminals 1 and 2.
  • Relay Output (COM, NO, NC): Connect to terminals 3, 4, and 5.
  • SSR Output (12VDC±3V, 20mA Max): Connect to terminals 11 and 12.
  • Sensor Input (RTD, TC): Connect to terminals 7, 8, 9, and 10, depending on sensor type.
  • Alarm Output (AL1): Connect to terminal 6.

For a comprehensive electronic manual with detailed wiring instructions and setup procedures, please scan the QR code provided on the back of your device or in the product images.

5. Operation

The TC3 series temperature controller features an intuitive front panel for setting and monitoring temperature. The display shows both the measured value and the set value, along with LED indicators for alarm (ALM), auto-tuning (AT), and output (OUT) status.

Panel layout for TC3-M model, indicating measured value, set value, alarm, output lights, and control keys
Figure 6: TC3-M Panel Resolution and Key Functions

Panel Controls:

  • SET Key: Used to enter parameter setting mode and confirm selections.
  • Left Key (<<): Typically used to shift digits during parameter setting.
  • Reduce Key (↓): Decreases the value of the selected parameter.
  • Increase Key (↑): Increases the value of the selected parameter.

Basic Temperature Setting:

  1. Press the SET key to enter the set value adjustment mode. The set value display will blink.
  2. Use the Reduce Key (↓) or Increase Key (↑) to adjust the desired temperature.
  3. Use the Left Key (<<) to move the cursor to adjust different digits.
  4. Press the SET key again to confirm the new set value and exit the setting mode.

For advanced settings, including PID parameters, alarm configurations, and input type selection, please refer to the detailed electronic manual accessible via the QR code.

6. Maintenance

To ensure the longevity and optimal performance of your VaneAims TC3 series temperature controller, follow these general maintenance guidelines:

  • Cleaning: Regularly wipe the unit with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the casing or display.
  • Environmental Conditions: Ensure the controller operates within the specified ambient temperature (-5~40℃) and humidity (35%~85%RH) ranges. Avoid exposure to direct sunlight, excessive dust, moisture, or corrosive gases.
  • Connections: Periodically check all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to inaccurate readings or operational failures.
  • Inspection: Inspect the unit for any signs of physical damage, such as cracks in the casing or frayed wires.
  • Power Supply: Ensure a stable power supply within the specified voltage range (AC85-265V).

The device features a detachable housing for convenient maintenance, as shown in some product images, allowing access to internal components if necessary for qualified technicians.

Internal view of the temperature controller showing SMT process high precision chip, switch power supply, and relay components
Figure 7: Internal Components and Workmanship

7. Troubleshooting

If you encounter issues with your VaneAims TC3 series temperature controller, consider the following basic troubleshooting steps:

  • No Power: Check the power supply connections (terminals 1 and 2) and ensure the voltage is within the AC85-265V range. Verify that the power source is active.
  • Incorrect Temperature Reading:
    • Ensure the sensor is correctly connected to terminals 7-10 and that the wiring is secure.
    • Verify that the input type configured in the controller matches your connected sensor (e.g., K-type, PT100). This setting is typically found in the advanced parameters.
    • Check the sensor itself for damage or malfunction.
  • Output Not Activating:
    • Confirm that the set temperature is correctly configured and that the measured temperature is outside the desired range to trigger the output.
    • Check the relay and SSR output connections (terminals 3-5 for relay, 11-12 for SSR).
    • Verify the output mode (ON/OFF or PID) and parameters are correctly set.
    • Ensure the OUT LED indicator is illuminated when the output should be active.
  • Alarm Not Triggering:
    • Check the alarm set point and ensure the measured temperature exceeds or falls below it as configured.
    • Verify the alarm output connection (terminal 6).
    • Ensure the ALM LED indicator is illuminated when the alarm condition is met.

For more complex issues or if the problem persists, consult the full electronic manual or contact VaneAims customer support.

8. User Tips

No specific user tips were available from reviews or Q&A for this product at this time. However, general best practices for temperature controllers include:

  • Always ensure your sensor type (e.g., K-type thermocouple, PT100 RTD) is correctly matched with the controller's input settings for accurate readings.
  • When using PID control, allow sufficient time for the auto-tuning function to optimize parameters for your specific heating/cooling system.
  • Consider the environment where the controller is installed; extreme vibrations or electromagnetic interference can affect performance.

9. Warranty and Support

For information regarding product warranty, returns, or technical support, please contact the seller directly. Ensure you have your purchase details and product model number available when seeking assistance.

© 2024 VaneAims. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.