1. Introduction
This manual introduces the assembly, installation, operation, and troubleshooting of the PowMr Hybrid Solar Inverter. Please read this manual carefully before installation and operation to ensure safe and efficient use of the device.
The PowMr Hybrid Solar Inverter is a multifunctional off-grid solar inverter that integrates an MPPT solar charging controller, a high-frequency pure sine wave inverter, and a UPS function module. It is designed for off-grid backup power supply and spontaneous self-use systems. Its compact size is achieved through a high-frequency transformer design, providing reliable power conversion.
For complete system operation, additional equipment such as photovoltaic modules, a generator, or a utility grid may be required. Consult your system integrator for specific architectural needs. An optional WiFi module allows users to monitor the solar system's status remotely via mobile phones or websites.
1.1. Key Features
- Pure sine wave output inverter.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Automatic restart function when AC is recovering.
- Overload, over temperature, and short circuit protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Optional WiFi with remote monitoring APP.
- Built-in 120A MPPT solar controller.
- For grid connection or off-grid use (6.2KW/4.2KW Hot Sale model).
- Dual AC Output (6.2KW Hot Sale model).
- With Mains electricity and generator inputs and dual AC outputs (6.2KW Updated model).
- With Parallel Function, up to 9 units (6.2KW Parallel model), for a total output of 55.8kW.
1.2. Basic System Architecture
The following diagram illustrates a basic application for the inverter/charger, showing its connection to solar panels, battery, utility/generator, and household appliances.
This inverter can power various appliances in home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.
2. Safety Regulations
WARNING: This article contains important safety and operation instructions. Please read and save this manual for future reference.
- Please choose the corresponding setting according to whether to use a lead-acid battery or lithium battery. If it is not set properly, the system may not operate normally.
- Before using the unit, please read all the instructions and cautionary notes on the unit and understand all battery models and relevant chapters in this manual.
- Never short-circuit AC output and DC input. Never connect the mains when the DC input is short-circuited.
- Never charge a non-rechargeable battery.
- Do not disassemble the unit. When maintenance or repair is needed, please send it to a professional technical service center. Incorrect reassembly may lead to electric shock or fire.
- To reduce the risk of electric shock, disconnect all wiring before attempting any maintenance or cleaning. Turning off the device will not reduce this risk.
- Be extra careful when using metal tools on or around the battery. Some potential risks, such as short circuits of batteries or other electronic components caused by sparks from falling tools, may lead to explosion.
- To ensure optimal operation of this off-grid solar inverter, select the appropriate cable size according to the instructions. It is very important to operate the off-grid solar inverter correctly.
- When disconnecting AC or DC terminals, strictly follow the installation procedure. For more details, refer to the "Installation" section in this manual.
- Grounding instruction: This off-grid solar inverter shall be connected to the permanent grounding wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- Provide a fuse that meets certain specifications for battery power supply as overcurrent protection.
- Warning!! Only professional service personnel can repair this equipment. If there are still errors after troubleshooting, please send this off-line solar inverter back to the local dealer or service center for maintenance.
3. Installation
3.1. Unpacking and Inspection
Unpack the inverter and ensure there are no damaged objects in the package. You should have received the following items:
- Inverter Unit x 1
- User Manual x 1
3.2. Preparation Before Installation
Before connecting all wirings, remove the bottom cover by unscrewing the two screws as shown in the product overview images.
3.3. Mounting the Inverter
Consider the following points before installing the equipment:
- Do not install the inverter on flammable building materials.
- Install on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- Leave a gap of 20-50 cm for ventilation and heat dissipation.
- The equipment's working environment temperature should be 0-55°C.
- It is best to install it vertically down against the wall, leaving a certain space with the ground.
CAUTION: SUITABLE FOR INSTALLATION ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Tighten the screws and fix the installation. M4 or M5 screws are recommended for machine fixing.
3.4. Battery Connection
WARNING: It is required to install an independent DC overcurrent protector or disconnect device between the battery and the inverter. All wiring must be performed by qualified personnel.
It is very important for system safety and efficient operation to use appropriate cables for battery connection. Refer to the table below for recommended cable specifications:
| Model | Wire Specification | Torque Value |
|---|---|---|
| 12V | 1 * 2/0 AWG (67mm2) | 2-3 Nm |
| 24V | 1 * 1/0 AWG (54mm2) | 2-3 Nm |
Note: The recommended charging current for lead-acid batteries is 0.2C (C is battery capacity).
3.4.1. Lead-Acid Battery Connection Steps:
- Connect the battery according to the recommended battery cable specifications.
- Connect all battery packs as needed.
- Insert the ring terminal of the battery cable into the inverter's battery connector flatly, ensuring bolts are tightened with a torque of 2-3 Nm. Verify correct polarities of battery and inverter.
- Connect all battery packs as shown in the diagram below (example for 12V and 24V models).
3.4.2. Lithium Battery Connection:
If using a lithium battery, only those matched with the BMS communication protocol are allowed.
- Connect the battery according to the recommended battery cable specifications.
- Insert the ring terminal of the battery cable into the inverter's battery connector flatly, ensuring bolts are tightened with a torque of 2-3 Nm. Verify correct polarities of battery and inverter.
- Connect one side of the RJ45 cable to the BMS communication port of the inverter.
- Insert the other side of the RJ45 cable into the RS485 communication port on the lithium battery.
Note: If you choose a lithium battery, ensure the battery and inverter are connected with a BMS communication cable, and select the battery type as "LIB" mode in the inverter settings.
3.5. AC Input/Output Connection
CAUTION: Before connecting to an AC input power source, install a separate AC breaker between the inverter and AC power source. This ensures the inverter can be securely disconnected during maintenance and is protected from overcurrent. There are two terminal blocks marked "IN" and "OUT". Do NOT mis-connect input and output connectors. All wiring must be performed by qualified personnel.
Refer to the table below for recommended AC cable specifications:
| Model | Wire Gauge | Torque Value |
|---|---|---|
| 12V/24V | 1 * 12 AWG | 1.2-1.6 Nm |
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
- Before making AC input/output connections, ensure the DC protector or disconnector is open.
- Remove 10mm of insulation from six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the screws. Connect the PE protective conductor (yellow-green) first.
- Then, insert the AC output conductors according to polarity identification at the terminal and tighten the screws.
- Ensure all wires are firmly connected.
3.6. PV Connection
CAUTION: Before connecting the PV module, install a separate DC circuit breaker between the inverter and the PV module. All wiring must be performed by qualified personnel.
It is very important for system safety and efficient operation to use appropriate cables for PV module connection. Refer to the table below for recommended cable specifications:
| Model | Wire Gauge | Torque Value |
|---|---|---|
| 12V/24V | 1 * 16 AWG | 1.2-1.6 Nm |
3.6.1. PV Module Selection:
When selecting PV modules, consider the following parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the min battery voltage.
Example PV module configurations (250Wp module):
| Solar Panel Parameters | Solar Input Range (Min/Max in serial) | Quantity of Panels | Total Input |
|---|---|---|---|
| -250Wp, Vmp: 30.1Vdc, Imp: 8.3A, Voc: 37.7Vdc, Isc: 8.4A, Cells: 60 | 3 pcs in serial | 3 | 750W |
| 6 pcs in serial | 6 | 1500W | |
| 8 pcs in serial | 8 | 2000W | |
| 12 pcs in serial | 12 | 3000W | |
| 13 pcs in serial | 13 | 3250W | |
| 8 pcs in serial and 2 sets in parallel | 16 | 4000W |
3.6.2. PV Module Connection Steps:
- Remove 10mm of insulation from positive and negative conductors.
- Check the correct polarity of connection cables from PV modules and PV input connectors. Connect the positive pole (+) of the connection cable to the positive pole (+) of the PV input connector. Connect the negative pole (-) of the connection cable to the negative pole (-) of the PV input connector.
- Ensure the wires are securely connected.
3.7. Final Assembly
After connecting all the wires, replace the bottom cover and secure it with the screws.
4. Operation
4.1. Power On/Off
After correctly installing the machine and connecting the battery, simply press the On/Off switch to turn on the machine.
4.2. Operation and Display
The operation and display panel is located on the front of the inverter. It includes four function keys and an LCD screen for indicating operation status and input/output power information.
4.2.1. RGB Light (Optional)
- Inverter state: Green light
- Utility state: Blue light
- Failure state: Red light
4.2.2. LED Indicator
| LED Indicator | State | Messages |
|---|---|---|
| AC / INV (Green) | Solid On | Output is powered by utility in Line mode. |
| Flashing | Output is powered by battery or PV in battery mode. | |
| CHG (Green) | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | |
| FAULT (Red) | Solid On | Fault occurs in the inverter. |
| Flashing | Warning condition occurs in the inverter. |
4.2.3. Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.2.4. LCD Display Icons
The LCD displays various icons to indicate the inverter's status and information. These include input source, configuration programs, fault information, output information, and battery information.
4.3. LCD Settings
Press and hold the "ENTER" button for 3 seconds to enter setting mode. Use "UP" or "DOWN" to select programs, and "ENTER" to confirm or "ESC" to exit. Key settings include:
- Program 01: Output Source Priority (SBU, SUL, or MKS priority)
- Program 02: Maximum Charging Current (10A to 100A)
- Program 03: AC Input Voltage Range (Appliances or UPS)
- Program 04: Power Saving Mode (Enable/Disable)
- Program 05: Battery Type (AGM, Flooded, User-Defined, LIB)
- Program 06: Auto Restart when Overload Occurs (Enable/Disable)
- Program 07: Auto Restart when Over Temperature Occurs (Enable/Disable)
- Program 08: Output Voltage (220V, 230V, 240V)
- Program 09: Output Frequency (50Hz, 60Hz)
- Program 10: Lithium Battery Protocol (PYLON, PACE)
- Program 11: Maximum Utility Charging Current (10A to 100A)
- Program 12: Setting Voltage Point back to Utility Charging (for SBU/MKS priority)
- Program 13: Set the Voltage Point back to Battery Discharge (for SBU/MKS priority)
- Program 16: Charger Source Priority (Solar first, Solar and Utility, Only Solar)
- Program 18: Alarm Control (Alarm on/off)
- Program 19: Auto Return to Default Display Screen (Enable/Disable)
- Program 20: Backlight Control (On/Off)
- Program 22: Beeps while Primary Source is Interrupted (On/Off)
- Program 23: Overload Bypass (Enable/Disable)
- Program 25: Record Fault Code (Enable/Disable)
- Program 26: Bulk Charging Voltage (C.V voltage)
- Program 27: Floating Charging Voltage
- Program 29: Low DC Cut-off Voltage
- Program 33: Battery Equalization (Enable/Disable)
- Program 34: Battery Equalization Voltage
- Program 35: Battery Equalized Time
- Program 36: Battery Equalized Timeout
- Program 37: Equalization Interval
- Program 39: Equalization Activated Immediately
- Program 48: RGB Lighting (On/Off)
4.4. Operating Mode Description
The inverter supports various operating modes, including Standby/Power Saving, Line Mode, and Battery Mode, each with specific charging and power supply behaviors.
| Operation Mode | Description | LCD Display (Example) |
|---|---|---|
| Standby / Power Saving Mode | No output is supplied, but it can charge batteries. In power saving mode, output is off if load is low. | (Charging by utility and PV energy) |
| Line Mode | Provides output power from the mains. Solar and mains supply power to loads simultaneously. | (Solar and mains supply power) |
| Battery Mode | Provides output power from battery and PV power. | (Battery supply power) |
5. Maintenance
5.1. Clearance and Maintenance for Anti-Dust Kit (Optional)
Every inverter is pre-installed with an anti-dust kit from the factory. This kit helps prevent dust from entering the inverter and enhances product reliability in harsh environments. The inverter automatically detects this kit and activates an internal thermal sensor to adjust internal temperature.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
5.1.1. Cleaning Steps:
- Remove the screws securing the anti-dust kit.
- Carefully remove the air filter.
- Clean the air filter.
- After cleaning, reinstall the dust removal net to the inverter.
6. Specifications
6.1. General Specifications
| Attribute | Value |
|---|---|
| Brand Name | PowMr |
| Model Number | Hybrid Solar Inverter |
| Rated Output Power | 6.2KW/6.2KVA |
| Output Voltage Range | 220-240VAC |
| Battery Voltage | 48VDC |
| Max PV Input Voltage | 500VDC |
| Output Current | MPPT 120A |
| Working Efficiency | >95% |
| Battery Type Compatibility | Lifepo4, Lithium, Flooded, Gel, Lead-acid Batteries |
| Size | 444x300x100 mm |
| Weight | 10KG |
| Output Frequency | 50HZ/60HZ |
| Is Smart Device | Yes |
| Certification | CE |
| Operating Temperature Range | -20°C to 55°C |
| Storage Temperature | -20°C~60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
6.2. Detailed Specifications (Model: POW-HVM4.2K-24V-D)
The following tables provide detailed specifications for various operating modes. Note that specifications may vary slightly between different models (e.g., 4.2KW vs 6.2KW, 24V vs 48V, Parallel vs Non-Parallel versions).
6.2.1. Specification of LINE Mode
| Parameter | Value |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 230Vac |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) |
| Output Short Circuit Protection | Battery mode: Electronic Circuits |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
6.2.2. Specification of Inverter Mode
| Parameter | Value |
|---|---|
| Rated Output Power | DC12V-2300VA/2300W; DC24V-4200VA/4200W |
| Output Voltage Waveform | Pure Sine Wave |
| Output Voltage Regulation | 230Vac±5% |
| Output Frequency | 60Hz or 50Hz |
| Peak Efficiency | 94% |
| Overload Protection | 5s@≥150% load; 10s@105%~150% load |
| Surge Capacity | 2* rated power for 5 seconds |
| Nominal DC Input Voltage | 12 Vdc / 24Vdc |
| Cold Start Voltage | 11.5 Vdc / 23.0Vdc |
| Low DC Cut-off Voltage (@Load < 20%) | 10.5 Vdc / 21.0Vdc |
| High DC Cut-off Voltage | 16 Vdc / 32Vdc |
| No Load Power Consumption | 20W / 30W |
| Saving Mode Power Consumption | <10W / <15W |
6.2.3. Specification of Charging Mode
| Parameter | 12V Battery Model | 24V Battery Model |
|---|---|---|
| Utility Charging Mode (Flooded Battery) | Bulk Charging: 14.6V | Bulk Charging: 29.2V |
| Utility Charging Mode (AGM / Gel Battery) | Bulk Charging: 14.1V | Bulk Charging: 28.2V |
| Floating Charging Voltage | 13.5Vdc | 27Vdc |
| Charging Algorithm | 3-Step | |
| Max. PV Array Power | 4000W | |
| Max. PV Current | 18A | |
| Nominal PV Voltage | 240V | |
| PV Array MPPT Voltage Range | 55V-500V | |
| Max. PV Array Open Circuit Voltage | 500V | |
| Max Charging Current | 100A | |
7. Troubleshooting
This section provides solutions to common problems encountered during the operation of the PowMr Hybrid Solar Inverter.
| Problem | LCD/Buzzer Indication | Explanation / Possible Cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD and buzzer active for 3 seconds, then off. | Battery voltage is too low. | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. Battery voltage is far too low. 2. Battery polarity is connected reversed. | 1. Check if batteries and wiring are connected well. 2. Re-charge battery. 3. Replace battery. |
| Mains exist but the unit works in battery mode. | The power-on icon of LCD flashes, and the status indicator icon flashes. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. |
| Buzzer beeps continuously and status indicator icon is always on. | Fault code 07 | Overload error. Inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. |
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 02 | Internal temperature of inverter component is overheated. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Fault code 03 | Battery is over-charged. | Return to repair center. | |
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06/58 | Output abnormal | 1. Reduce the connected load. 2. Return to repair center. | |
| Fault code 08/09/53/57/51/52/55 | Internal components failed, Over current or surge, Bus voltage too low, Output voltage unbalanced. | Restart the unit, if the error happens again, please return to repair center. |
8. User Tips
- Battery Compatibility: The inverter is compatible with LiFePO4 batteries. Ensure you select the correct battery type in the LCD settings (Program 05: LIB) and connect the BMS communication cable for optimal performance.
- Output Voltage: The AC output voltage is adjustable (220V/230V/240V). If you require a specific voltage like 200V for certain regions (e.g., Japan), verify if the adjustable range meets your needs or if a 220V setting is acceptable for your appliances.
- Grid Interaction: This inverter is primarily designed as an off-grid solar inverter for backup power and self-consumption. It is not explicitly designed for selling excess solar energy back to the grid.
- Parallel Operation: For increased power output, certain models (e.g., 6.2KW Parallel version) support connecting up to 9 units in parallel, achieving a total output of 55.8kW. Ensure proper parallel connection procedures are followed.
9. Warranty and Support
For technical support, warranty claims, or service, please contact PowMr directly. Ensure you have your product model and serial number ready when contacting support.
- Manufacturer: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Email: support@powmr.com
- Website: www.powmr.com
- Phone/Fax: +86755-28219903
A PDF version of this user manual is available for download: User Manual (PDF)