NJTY T600/T600A

Contents

NJTY T600/T600A Infrared Thermometer User Manual

Non-contact IR-LCD Heat Industrial Pyrometer

1. Introduction

This infrared thermometer is designed for measuring the surface temperature of objects. It is suitable for various hot, hazardous, or hard-to-reach objects, allowing for safe and quick non-contact temperature measurement.

The device is composed of an optical system, a photoelectric sensor, a signal amplifier, a signal processing circuit, and an LCD display. The optical system focuses the infrared energy emitted by the object's surface onto the photoelectric sensor, which then converts the energy into a corresponding electrical signal. This signal is processed and displayed as a temperature reading on the LCD.

2. Safety Information

2.1. Warnings

  • Before using this unit, carefully inspect the plastic housing. Do not use if there is any damage.
  • Do not point the laser directly at eyes or indirectly off reflective surfaces.
  • Do not use this unit in environments with explosive gas, steam, or excessive dust.

2.2. Cautions

To prevent damage to the unit or the target, observe the following precautions:

  • Avoid exposure to electromagnetic fields (EMF) from arc welders or induction heaters.
  • Allow 30 minutes for the unit to stabilize before use if it has experienced thermal shock (large or abrupt ambient temperature changes).
  • Do not leave the unit on or near objects of high temperature.
Warning: Not for use on humans
Warning: This infrared thermometer is not designed for measuring human body temperature. It is intended for inanimate objects only.

3. Product Overview

3.1. Key Features

  • High and Low Temperature Measurement: Measures temperatures from -50°C to 600°C (-58°F to 1112°F).
  • Strong Laser Beam: Provides precise targeting for accurate measurements.
  • High Quality Construction: Made from durable, drop-resistant ABS material.
  • Emissivity Adjustable (T600A Model): The T600A model allows adjustment of emissivity based on the material being tested for more accurate readings.
  • Fast Measurement: Provides readings in approximately 0.5 seconds.
  • HD Backlight: Clear, backlit LCD display for readability in various lighting conditions.
  • °C/°F Conversion: Easily switch between Celsius and Fahrenheit units.
  • Auto Shut-down: Conserves battery life by automatically turning off after a period of inactivity.
Comparison of T600 and T600A models
Comparison of NJTY T600 (Basic version) and T600A (Upgraded version) infrared thermometers. The T600A features an adjustable emissivity mode.

3.2. Components and Display Indicators

The device features an eye-protection LCD display with backlight for night use. Key indicators on the display include:

  • HOLD: Data Hold mode.
  • SCAN: Scanning mode.
  • Laser On: Indicates the laser is active.
  • Backlight: Indicates backlight is on.
  • Low Battery Indicator: Alerts when battery is low.
  • °C/°F: Temperature unit.
  • Reading: Current temperature value.
  • MAX: Maximum temperature recorded.
  • ε: Emissivity symbol (for T600A).
NJTY T600 Infrared Thermometer display and features
Close-up view of the NJTY T600 infrared thermometer, highlighting its features like fast measurement, laser aiming, HD backlight, and auto shut-down.
Dimensions of the infrared thermometer
Dimensions of the infrared thermometer: 14.5cm (5.7in) length, 6.8cm (2.7in) width, 3.5cm (1.4in) depth.

4. Specifications

ParameterValue
Measuring Temperature Range-50°C to 600°C (-58°F to 1112°F)
Measurement Accuracy≥0°C (32°F): ±1.5°C (±2.7°F) or ±1.5% of reading; <0°C (32°F): ±3°C (±5.4°F) or ±3% of reading
Emissivity0.1-1.0 adjustable (T600A model)
Maximum Value DisplayYES
Repeatability1% of reading or 1°C (33.8°F)
Response Time500mSec, 95% Response
Response Wavelength8-14um
Ambient Operating Temperature0°C to 50°C (32°F to 122°F)
Relative Humidity10-90%RH non-condensing
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Power Supply2 x 1.5V AAA Batteries (Not included)
Battery Life12 hours (laser off)
Distance to Object Ratio (D:S)12:1

5. Setup

5.1. Battery Installation

  1. Open the battery compartment located on the handle.
  2. Insert two 1.5V AAA batteries, ensuring correct polarity.
  3. Close the battery compartment. The lock has been upgraded to be stronger and prevent the battery from falling out.
Video demonstrating the unboxing, battery installation, and basic operation of the infrared thermometer.
Battery replacement diagram
Diagram showing easy battery replacement for the infrared thermometer. Use a flathead screwdriver to open the battery cover, insert two AAA batteries, and then close the cover securely.

6. Operation

6.1. Measurement Method

When taking measurements, pay attention to the Distance-to-Spot (D:S) ratio. As the distance (D) from the thermometer to the target surface increases, the spot diameter (S) on the target surface becomes larger. The D:S ratio for this device is approximately 12:1.

Distance-to-Spot ratio diagram
Diagram illustrating the high accuracy and Distance-to-Spot (D:S) ratio of 12:1 for the infrared thermometer. Ensure the target is larger than the measuring area for accurate readings.

6.2. Single Measurement

Pull and release the trigger. The laser pointer will activate to help aim at the target (the laser is for aiming only). The temperature of the target will be displayed on the LCD. The display will show 'HOLD' indicating the reading is held.

6.3. Continuous Measurement

Pull and hold the trigger. Slowly move the thermometer across the target area. The thermometer will continuously scan and display the temperature on the LCD. The 'SCAN' symbol will be displayed. The maximum temperature value during continuous measurement will also be shown on the display.

6.4. Button Functions

  • Laser Point (Button 2): Press to turn the laser pointer on or off. The laser is used for aiming only.
  • Backlight (Button 4): Press to turn the LCD backlight on or off.
  • Temperature Unit (°C/°F) (Button 3): Press to switch between Celsius and Fahrenheit.
  • Emissivity Adjustment (T600A Model Only): Long press Button 3. The preset emissivity (0.95) will be displayed. Use Button 2 (down arrow) or Button 4 (up arrow) to decrease or increase the emissivity. Press Button 3 again to save the new emissivity setting.
T600A Emissivity Adjustment
Detailed instructions on how to adjust emissivity on the T600A model: 1. Long press the °C/°F key for two seconds to enter emissivity adjustment mode (preset 0.92 will be displayed). 2. Press the down arrow key to reduce emissivity. 3. Press the up arrow key to increase emissivity. Press °C/°F again to save.

6.5. Emissivity Table

Different materials have different emissivity values. For more accurate measurements, especially with the T600A model, adjust the emissivity setting according to the material being measured. The table below provides common emissivity values:

MaterialEmissivityMaterialEmissivityMaterialEmissivityMaterialEmissivity
Aluminum0.30Iron0.70Asbestos0.95Brick0.50
Bituminous0.95Limestone0.98Basalt0.70Oil0.94
Brass0.50Paint0.93Brick0.90Paper0.95
Carbon0.85Plastic0.95Ceramics0.95Rubber0.95
Concrete0.95Sand0.90Copper0.95Skin0.98
Oil Sludge0.94Snow0.90Frozen Items0.90Steel0.80
Hot Food0.93Textile0.94Glass0.85Water0.93
Ice0.98Wood0.94

6.6. Specific Measurement Considerations

Measurement method for boiling liquids
When measuring boiling liquids, ensure that smoke or steam from boiling water does not come into contact with the temperature sensing zone. Maintain a measurement angle of approximately 45°–60° to avoid inaccurate readings.

6.7. Wide Applications

Various applications of the infrared thermometer
The thermometer can be used for various applications including measuring automobile engine temperature, industrial circuit board temperature, frying industry temperature, food temperature, and air conditioning system temperature.
Application scenarios of thermometer
Illustrations of various application scenarios for the thermometer, including measuring automobile engines, barbecue baking, automobile air conditioning, and geothermal heating.

7. Maintenance

7.1. Lens Cleaning

To clean the lens, first use compressed air to blow away any loose debris. Then, use a camel hair brush to gently wipe away any remaining small particles. Finally, carefully wipe the surface with a soft, damp cotton cloth.7.2. Shell Cleaning

Clean the device's shell using a sponge or soft cloth with mild soap and water. Do not immerse the thermometer in water.

8. Troubleshooting

  • No Display: Check battery installation and ensure batteries are not depleted. Replace with fresh 1.5V AAA batteries if necessary.
  • Inaccurate Readings: Ensure the Distance-to-Spot ratio is appropriate for the target size. For T600A models, verify the emissivity setting matches the material being measured. Allow 30 minutes for the device to stabilize if it has been exposed to significant temperature changes.
  • Laser Not Working: Press the laser button (Button 2) to ensure it is activated.
  • Backlight Not Working: Press the backlight button (Button 4) to ensure it is activated.

9. User Tips

  • For best accuracy, ensure the target object is larger than the measurement spot size.
  • Always aim the laser at the center of the area you wish to measure.
  • When measuring shiny surfaces, consider applying a matte black paint or tape to the surface to improve accuracy, or use the emissivity adjustment feature on the T600A model.
  • Keep the lens clean to ensure clear and accurate readings.

10. Frequently Asked Questions

  • Q: Can this thermometer measure body temperature?
    A: No, this infrared thermometer is designed for industrial and household use on inanimate objects and is not suitable for measuring human body temperature.
  • Q: Are batteries included?
    A: No, two 1.5V AAA batteries are required and are not included with the product.
  • Q: How do I switch between Celsius and Fahrenheit?
    A: Press Button 3 (labeled °C/°F) to toggle between Celsius and Fahrenheit units.
  • Q: What is emissivity and why is it important?
    A: Emissivity is a measure of an object's ability to emit infrared energy. Different materials have different emissivity values. Adjusting the emissivity (on T600A models) to match the target material helps ensure more accurate temperature readings.

11. Warranty and Support

For detailed warranty information and further support, please refer to the complete user manual available as a PDF: Download User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.