INKBIRDPLUS PTH-10C

Contents

INKBIRDPLUS Portable CO2 Detector PTH-10C User Manual

Model: PTH-10C

Brand: INKBIRDPLUS

1. Introduction

The INKBIRDPLUS Portable CO2 Detector PTH-10C is a compact and versatile device designed to monitor carbon dioxide levels in various environments. Featuring a superior NDIR sensor, full-color LCD display, and customizable alarm functions, it helps ensure fresh air and protect health in homes, offices, grow tents, and outdoor settings.

Warning!

  • The carbon dioxide measurement function and over-standard alarm provided by this product are for reference only and cannot be used as the sole basis.
  • During daily use, pay attention to safety and keep good ventilation at all times to avoid danger!

2. Product Overview

The PTH-10C features a clear display and intuitive controls, designed for ease of use and portability.

INKBIRDPLUS PTH-10C CO2 Detector with labeled parts: Air Vent, Lanyard hole, Input Port, Function button, and screen display showing CO2 ppm, concentration, light indication, buzzer, and battery capacity.
Figure 2.1: Product Components and Display

Key Features:

  • Superior NDIR Sensing Technology: Provides high precision, strong anti-interference ability, and excellent stability for CO2 measurements.
  • Full Color LCD Display: Easy-to-read display with an eye-caring ECO mode for power saving.
  • Custom CO2 Alarm Value: Allows users to set their preferred CO2 alarm threshold.
  • Automatic Calibration ON/OFF: Ensures accurate readings over time.
  • USB Rechargeable Design: Convenient Type-C charging.
  • Portable Design: Compact size with a lanyard for easy carrying.
Diagram showing the key features of the PTH-10C: NDIR Sensing Technology, Full Color LCD Display, Custom CO2 Alarm Value, Automatic Calibration ON/OFF, Power-saving ECO Mode, USB Rechargeable Design.
Figure 2.2: Key Product Features

3. Specifications

ParameterValue
Model NumberPTH-10C CO2 Detector
Carbon Dioxide Range400~5000 ppm [±(50ppm + 5%)]
CO2 Sound Alarm Range(default) 1500 ppm
BatteryBuilt-in lithium-ion polymer battery (3.7V, 1000mAh)
InputType-C, DC 5V ~ DC 24V (Max)
Fast Charging ProtocolQC2.0, PD3.0, AFC, USB C UFP (BC1.2 DCP CDP SDP) and other common fast charging protocols
Storage Temperature-10℃ ~ 55℃ / 14°F ~ 131°F
Product Size76mm x 70mm x 30mm (2.99 in x 2.75 in x 1.18 in)
MaterialABS Shell
CertificationCE

4. Setup and Initial Use

4.1 Charging the Device

Before first use, ensure the device is fully charged. Connect the provided Type-C cable to the Input Port on the device and to a compatible USB power source. The device supports fast charging protocols like QC2.0, PD3.0, AFC, and USB C UFP (BC1.2 DCP CDP SDP).

Close-up view of the 1000mAh large-capacity lithium battery inside the PTH-10C, highlighting its 72-hour continuous use capability.
Figure 4.1: Internal Battery and Charging Capability

4.2 Power On/Off

  • Power On: Press and hold the function button until the display lights up.
  • Power Off: Press and hold the function button until the display turns off.

4.3 Power-Saving Mode

If there is no button operation within 5 minutes, the device automatically enters power-saving mode. Press the function button briefly to wake it up.

5. Operating Instructions

5.1 Understanding the Display and Light Indication

The device features a full-color LCD display and a tri-color indicator light to show CO2 concentration levels:

  • Green Light (400-699ppm): Indicates good CO2 concentration.
  • Yellow Light (700-1499ppm): Indicates medium CO2 concentration, an alert level.
  • Red Light (1499-5000ppm): Indicates dangerous CO2 concentration.
Diagram showing the tri-color CO2 indication light ranges: Green for 400-699ppm (good), Yellow for 700-1499ppm (medium), and Red for 1499-5000ppm (dangerous).
Figure 5.1: Tri-color CO2 Indication Light Levels

5.2 Customizing Sound Alarm Value

You can set a custom CO2 concentration level at which the device will sound an alarm.

  1. Double-click the function button to enter setup mode. The current alarm value will be displayed.
  2. Press the function button briefly to adjust the hundreds digit of the alarm value.
  3. Long press the function button to confirm the hundreds digit and move to the tens digit setting.
  4. Repeat steps 2 and 3 for the tens and units digits.
  5. After setting the units digit, long press the function button to confirm and exit the setting mode.

5.3 Turning Alarm Sound On/Off

You can enable or disable the audible alarm for high CO2 levels.

  1. Double-click the function button to enter setup mode.
  2. Press the function button briefly to toggle between 'C-ON' (alarm on) and 'C-OF' (alarm off).
  3. Long press the function button to confirm your selection and save the setting.

5.4 Automatic Calibration On/Off

The device supports automatic calibration to maintain accuracy.

  1. Double-click the function button to enter setup mode.
  2. Press the function button briefly to toggle between 'C-ON' (automatic calibration on) and 'C-OF' (automatic calibration off).
  3. Long press the function button to confirm your selection and save the setting.

5.5 Manual Calibration of CO2 Measurements

For optimal accuracy, manual calibration can be performed in an open environment.

  1. Ensure the device is powered off.
  2. Long press the function button. The screen will display "-CAL" within 2 seconds.
  3. Continue holding the button until the screen displays a 200-second countdown (e.g., "0199"). Release the function button.
  4. During this 200-second countdown, the device is calibrating the carbon dioxide concentration value.
  5. After the countdown is complete, the device will automatically power on, indicating successful calibration.

Important Note for Calibration:

During the calibration of the carbon dioxide value, you must place the device in a well-ventilated place and ensure that no one is close to it, so as not to interfere with the calibration effect. Otherwise, an incorrectly calibrated base number will result in incorrect measurements.

5.6 Product Demonstration Video

Video 5.1: A demonstration of the INKBIRDPLUS Portable CO2 Monitor PTH-10C, showcasing its display, NDIR sensing, alarm features, battery life, customization options, calibration process, and portability.

6. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Environmental Protection: Do not expose this product to water and dust. Avoid placing it in high-temperature environments exceeding 70°C (158°F) or near open flames.
  • Charging: Always use a charging plug that meets the specifications. Using an incompatible charger may damage internal components.
  • Storage: If storing the device for a long period, ensure it is fully charged before turning it off and putting it away.
  • Disassembly: The device is a precision measuring instrument; unauthorized disassembly is not permitted and will void the warranty.

7. Troubleshooting

  • Inaccurate Readings: If measurements seem unstable or inaccurate, perform a manual calibration in a well-ventilated, open environment away from people.
  • Settings Not Saved: The device may not retain alarm settings (e.g., alarm sound on/off) after being powered off and on again. You might need to re-apply these settings each time you power on the device.
  • Screen Visibility Issues: Some users report that the screen clarity can vary depending on the viewing angle. Try adjusting the device's position or your viewing angle for better visibility.
  • Alarm Re-triggering: If the alarm sound is turned on and triggered, a short press of the function key will stop it. However, if the CO2 level drops below the alarm threshold and then rises to exceed it again, the alarm will re-trigger.
  • Temperature/Humidity Not Displayed: While the device may contain temperature and humidity sensors, the display might not show these readings. Refer to the product specifications for confirmed display features.
  • Slow Charging/Short Battery Life: Ensure both your charging cable and power adapter support the specified fast charging protocols (QC2.0, PD3.0, AFC, USB C UFP) for optimal charging speed. Battery life is approximately 2-3 days on a full charge.

8. User Tips

  • Optimal Viewing Angle: For best screen clarity, some users find viewing the display at a slight angle (e.g., 45-degrees from the right side) to be more effective than directly head-on.
  • Regular Calibration: To ensure the most accurate CO2 readings, perform manual calibration periodically, especially if you notice inconsistent measurements. Always do this in a fresh air environment.
  • Alarm Management: Be aware that alarm settings may reset upon power cycling. If you prefer the alarm off, you might need to disable it after each power-on.

9. Warranty and Environmental Disposal

9.1 Warranty Information

This product comes with a 1-year warranty against quality issues caused by any manufacturing defect or defective workmanship. The warranty excludes disposable batteries or damage caused by accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

9.2 Environmental Disposal

Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service.

CE FC RoHS compliance logos

Made in China

For further assistance, please refer to the official user manual PDF: View User Manual (PDF)


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.