VAKIND 200EP

Contents

200EP Tone Generator Kit User Manual

Model: 200EP | Brand: VAKIND

1. Introduction

The VAKIND 200EP Tone Generator Kit is a high-accuracy wire tester designed for efficient maintenance and testing of various cables and wires, particularly in network and telecommunication applications. This kit provides essential tools for circuit tracing, short circuit testing, and identifying cable integrity with ease and precision.

Image showing the 200EP Inductive Amplifier (probe) and Tone Generator (transmitter) components.
The 200EP Tone Generator Kit, featuring the Inductive Amplifier and Tone Generator.

2. Product Overview

2.1 Components

The 200EP Tone Generator Kit typically includes the following:

  • 1 x Inductive Amplifier (Probe)
  • 1 x Tone Generator (Transmitter)
  • 1 x Storage Bag
  • 1 x User Manual
  • 1 x Replacement Head (for the Inductive Amplifier)
Image titled 'Included' showing the Tone Generator, Inductive Amplifier, and connecting cables.
Included components of the 200EP Tone Generator Kit.

2.2 Key Features

  • High-Quality Construction: Made from durable, wear-resistant, and corrosion-resistant materials for long-term reliability.
  • Insulated Probe with Built-In Speaker: Designed to prevent conductor short circuits, enhancing user safety during operation.
  • Multiple Testing Functions: Capable of circuit tracing, short circuit testing, and identifying noise/ringing on lines.
  • Clamp Mode Testing: Allows for direct measurement of non-terminal cables, as well as testing telephone and network lines.
  • Optional Continuous or Adjustable Generator: Provides flexibility for accurate and reliable test results.
  • One-Button Operation: Simplifies the testing process for quick and efficient use.
Image of the 200EP Tone Generator Kit with a background of a technician working on cables. Text: 'CABLE TESTER TONE GENERATOR. Application in cable and wire repair and testing.'
The 200EP Kit in action, ideal for cable and wire repair and testing.

3. Specifications

AttributeValue
Model Number200EP
Brand NameVAKIND
GainNominal 30dB
Input ImpedanceNominal 100M ohms
Metal Needle Tip Resistance0 ohms
Plastic Prompt Resistance300 ohms
Battery Type1 x 9V DC battery (NEDA 1604, JIS 006P, or IEC 6LR61)
Battery Life (Nominal)50 hours
Operating Temperature0 ℃ - 50 ℃ (32 ℉ - 122 ℉)
WeightApproximately 300 grams / 10.6 ounces
Dimensions (Inductive Amplifier)Approximately 231mm x 55mm x 28mm (9.09in x 2.16in x 1.102in)
MaterialPlastic
OriginMainland China
CertificationNone
Diagram illustrating the dimensions of the Inductive Amplifier: 231mm length, 55mm width, 28mm thickness.
Dimensions of the Inductive Amplifier.

4. Safety Information

  • Always ensure the device is powered off when not in use or during battery replacement.
  • Use only the specified 9V DC battery (NEDA 1604, JIS 006P, or IEC 6LR61).
  • When replacing the battery, do not overtighten the screw on the battery compartment.
  • The insulated probe is designed for safety; however, always exercise caution when working with electrical circuits.
  • Avoid exposing the device to extreme temperatures or moisture.
  • Do not attempt to open or repair the device yourself, as this may void any potential support and could be unsafe.
Bottom view of the Inductive Amplifier, showing battery compartment and safety markings. Text: 'BATTERY REPLACEMENT: USE STANDARD 9VDC BATTERY. DO NOT OVERTIGHTEN SCREW.'
Battery compartment details and safety reminder.

5. Setup

5.1 Battery Installation

  1. Locate the battery compartment on the Inductive Amplifier (probe) and the Tone Generator.
  2. Open the battery cover.
  3. Insert one 9V DC battery into each unit, ensuring correct polarity.
  4. Close the battery cover and secure it gently. Do not overtighten the screw.

5.2 Connecting the Tone Generator

The Tone Generator can be connected to the cable you wish to trace using its various connectors (e.g., alligator clips, RJ11/RJ45 if applicable, though not explicitly detailed in provided data, standard for such devices). Ensure a secure connection to the cable or wire pair.

6. Operating Instructions

6.1 Basic Cable Tracing

  1. Connect the Tone Generator: Attach the Tone Generator to one end of the cable or wire pair you want to trace.
  2. Activate Tone Generator: Turn on the Tone Generator. Select either continuous or adjustable tone mode as needed.
  3. Use the Inductive Amplifier: Turn on the Inductive Amplifier. Hold the insulated probe near the suspected cable path.
  4. Trace the Signal: Move the probe along the cable path. The built-in speaker on the Inductive Amplifier will emit an audible tone, which will be loudest when the probe is directly over the target cable.
  5. Identify Cable: Follow the strongest tone to accurately identify the cable among a bundle or through walls/conduits.
User operating the Inductive Amplifier to trace cables in a network rack. Text: 'ACCURATE & PROFESSIONAL. Quickly tracking | One button operation.'
Quickly tracking cables with one-button operation.

6.2 Advanced Testing Functions

  • Short Circuit Testing: The Tone Generator can be used to identify short circuits by observing changes in the tone or indicator lights (if present) when a short is detected.
  • Noise/Ringing Identification: The Inductive Amplifier can help identify unwanted noise or ringing on telephone lines, aiding in troubleshooting line quality issues.
  • Clamp Mode Testing: For non-terminal cables or specific telephone/network line testing, utilize the clamp mode (if available on your specific Tone Generator model) for direct measurement without needing to terminate the cable.

7. Maintenance

7.1 Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the plastic casing.

7.2 Battery Replacement

Replace batteries when the tone becomes weak or the device fails to power on. Refer to Section 5.1 for battery installation instructions.

7.3 Storage

When not in use for extended periods, remove the batteries to prevent leakage and store the kit in its provided storage bag in a cool, dry place away from direct sunlight.

8. Troubleshooting

  • No Tone/Weak Tone:
    • Check if batteries are correctly installed and have sufficient charge. Replace if necessary.
    • Ensure the Tone Generator is properly connected to the cable.
    • Verify both the Tone Generator and Inductive Amplifier are powered on.
    • Adjust the sensitivity on the Inductive Amplifier if available.
  • Intermittent Tone:
    • Check for loose connections on the Tone Generator.
    • Ensure the cable being traced is not damaged or has intermittent faults.
  • No Power:
    • Check battery installation and charge.
    • Ensure power switches are fully engaged.

9. User Tips

While no specific user tips were available from reviews or Q&A, general best practices for cable tracing include:

  • Always start with a low sensitivity setting on the Inductive Amplifier and increase it as needed to avoid picking up interference from adjacent cables.
  • When tracing through walls, move the probe slowly and methodically to pinpoint the exact location of the cable.
  • For noisy environments, try to shield the probe from external electromagnetic interference.

10. Support

For any issues not covered in this manual or for further assistance, please contact the seller or manufacturer directly. Keep your purchase information handy for quicker service.

© 2023 VAKIND. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.