1. Introduction
The TELEHILL VAC8810 is a 2.4-inch Color LCD Wireless Battery Capacity Tester, Coulometer, Current Voltage Power Meter, and Voltmeter. This multiplex wireless Hall coulometer is designed for universal battery applications, offering wireless transceiver data and real-time capacity detection. It provides comprehensive monitoring of battery parameters, making it an essential tool for various power detection scenarios.

2. Features
- Wireless Data Transmission: Avoids interference from complex wiring between the display and the detection module.
- Non-Contact Current Detection: Utilizes a Hall sensor for safe, reliable, and convenient current measurement without breaking the circuit.
- Comprehensive Display: Simultaneously shows voltage, current, power, temperature (optional), capacity, remaining capacity percentage, and running time.
- Dual Relay Interface: Features charge and discharge double relay interfaces with 5 working modes for automatic disconnection and closing of charge/discharge circuits.
- Advanced Protection Functions: Includes charge overvoltage (OVP), discharge undervoltage (LVP), charge overcurrent (OCP), and discharge overcurrent (NCP) protection, accompanied by a buzzer alarm.
- Power-Off Memory: Retains recorded AH and WH values even after power loss.
- Dynamic Charging Indicator: Charging progress bar switches to a color running water light display with a breathing light effect.
- Waveform Curve Display: Provides voltage, current, and temperature waveform curve visualization.
- TTL Serial Communication: Facilitates secondary development and integration.
- Dual Display Colors: Offers two switchable display colors to suit user preferences.
- Upgraded Features: Incorporates a 32-bit main control chip, comfortable silicone buttons, and bidirectional current detection.

3. Package Contents
The VAC8810 package typically includes the following components:
- 1 x LCD Monitor (Display Unit)
- 1 x Measurement Module (Measurement Box)
- 1 x USB Data Cable (0.75 meters USB to MiniUSB)
- 1 x User Manual (Chinese and English)
- 3 x Connection Cables (0.5 meters x H2.54 Red Black Line)
- 1 x Hall Sensor (Standard closed type; optional open type may be available)
- 1 x Temperature Line (Optional, for temperature measurement)


4. Specifications
The following table outlines the technical specifications of the VAC8810:

| Parameter | Description |
|---|---|
| Measurement Range (Self-Powered) | 8V~120V |
| Measurement Range (Independent Power Supply) | 0-120V (120V series), 0-500V (500V series) |
| Input Current Measurement Range | 0.1-50A (50A series), 0.2-100A (100A series), 0.3-200A (200A series), 0.4-300A (300A series), 0.5-500A (500A series) |
| Display Method | 2.4 inch color LCD display |
| External Power Supply Voltage | 8-120V |
| Language | Chinese/English |
| Display Power Supply | USB powered 5V, Independent power supply 8-12V |
| Measuring Range (Capacity) | 0.000AH~99999.9 AH |
| Measuring Range (Energy) | 000.00KWH~9999.9KWH |
| Measuring Range (Power Value) | 000.0~999KW |
| Measuring Range (Time) | 0-100 hours |
| Measuring Range (Temperature) | 000~150 °C |
| Accuracy (Voltage) | ±(1%+2) words |
| Accuracy (Current) | ±(1%+5) words |
| Accuracy (Temperature) | ±2°C |
| Measurement Rate | 20 times/second |
| Relay Delay Time | (0-100)S |
| Serial Communication Baud Rate | 9600Bps |
| Wireless Communication Distance (Normal Version) | Open land, single group, 10 meters |
| Wireless Communication Distance (Enhanced Version) | Open land, single group, 50 meters |
| Protection Type (OVP) | Overvoltage Protection (0.1~500V) |
| Protection Type (LVP) | Undervoltage Protection (0.1~500V) |
| Protection Type (OCP) | Charging Overcurrent Protection (0.1~500A) |
| Protection Type (NCP) | Discharge Overcurrent Protection (0.1~500A) |
5. Setup
5.1 Component Identification
Familiarize yourself with the various ports and interfaces on the measurement box and display unit.


5.2 Hall Sensor Types
The Hall sensor is crucial for current measurement. Two types are available:
- Standard Closed Hall Sensor: The ring cannot be opened.
- Optional Open Hall Sensor: The ring can be opened and installed without removing wires.

5.3 Wiring Diagrams
Proper wiring is essential for accurate and safe operation. Refer to the diagrams below for different power supply and relay configurations.

- Two-wire power supply wiring diagram: Connects the measurement box directly to the battery for power.
- Three-wire external power supply wiring diagram: Uses an external power source for the measurement box, adjusting the jump cap to the 3/W position.
- Discharge relay wiring diagram: Shows how to integrate a discharge relay for automatic control.
- Charging relay wiring diagram: Shows how to integrate a charging relay for automatic control.
Important: Ensure all connections are secure and polarity is correct before powering on the device. Incorrect wiring can damage the instrument or the connected battery.
6. Operation
6.1 Display Descriptions
The 2.4-inch color LCD provides a clear overview of all measured parameters. Refer to the diagram below for an explanation of each display element.

6.2 Introduction to Curves
The device can display waveform curves for voltage, current, and temperature, providing a visual representation of parameter changes over time.

7. Maintenance
- Environmental Conditions: Keep the instrument in a dry environment. The working temperature range is -10~50℃, and the storage temperature range is -20~70℃.
- Physical Handling: Avoid moving the instrument violently when it is working normally to prevent irreparable damage to the internal circuit.
- Cleaning: Use a soft, dry cloth to clean the display and casing. Do not use abrasive cleaners or solvents.
- Disassembly: Do not attempt to disassemble the instrument. Unauthorized disassembly will void the warranty.
8. Troubleshooting
- Instrument Damage: If the instrument is damaged or malfunctions, verify that it was operated within its specified voltage and current ranges. Exceeding these limits can cause permanent damage.
- Incorrect Measurements: If measurements appear incorrect, check all wiring connections, especially the positive and negative poles. Reversed connections will prevent correct measurement.
- No Display/Power: Ensure the display unit is properly powered via the 5V USB connection or the 8-12V independent power supply, as per your setup.
- No Wireless Connection: Check the wireless signal indication on the display. Ensure the measurement module and display are within the specified communication distance (10m for normal version, 50m for enhanced version in open land).
9. User Tips
- Hall Sensor Replacement: If you require a replacement Hall sensor, particularly for a specific amperage (e.g., 100A), check with the seller or manufacturer for compatible spare parts.
- Application Versatility: The VAC8810 is suitable for a wide range of applications, including electric car power detection, photovoltaic system inspection, cruise ship battery detection, RV power detection, and general battery rack monitoring.

10. Safety Precautions
- Do not exceed the specified voltage and current ranges of the instrument. Doing so may cause damage to the device and connected equipment.
- Always ensure correct polarity when connecting the device to a battery or power source. Incorrect connections can lead to inaccurate measurements or damage.
- Avoid disassembling the instrument. Any damage incurred from unauthorized disassembly will void the product warranty.
- Handle the instrument with care. Avoid violent movements or impacts, especially during operation, to prevent internal circuit damage.
- Operate and store the instrument within the recommended temperature ranges (-10~50℃ for operation, -20~70℃ for storage) and in a dry environment.
- Keep the device away from water, moisture, and extreme temperatures.
11. Warranty and Support
This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For warranty claims or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase. Please note that damage caused by improper use, exceeding specified limits, or unauthorized disassembly is not covered under warranty.