1. Introduction
This manual provides essential information for the safe and effective installation, operation, and maintenance of LCTC Slim Solid State Relays, specifically models SSR-41FDA and SSR-41FDD. These non-contact relays are designed for various control applications, offering reliable switching with a compact form factor.
2. Product Overview
The LCTC Slim Solid State Relays are compact, high-performance switching devices. The SSR-41FDA model is designed for DC control of AC loads, while the SSR-41FDD model is for DC control of DC loads. Both models feature a 6A peak current rating and are suitable for insert installation.


3. Specifications
Detailed specifications for each model are provided below:
3.1. SSR-41FDA (DC Control AC)

| Parameter | Value |
|---|---|
| Model | SSR-41FDA |
| Control Mode | DC TO AC |
| Control Voltage | 3-32VDC |
| Load Voltage | 24-250VAC |
| Peak Current | 6A |
| Off State Time | ≤10ms |
| Operating Current | 50mA-1A |
| Installation Method | Insert installation |
3.2. SSR-41FDD (DC Control DC)

| Parameter | Value |
|---|---|
| Model | SSR-41FDD |
| Control Mode | DC TO DC |
| Control Voltage | 3-32VDC |
| Load Voltage | 5-60VDC |
| Peak Current | 6A |
| Off State Time | ≤10ms |
| Operating Current | <0.8A |
| Installation Method | Insert installation |
3.3. General Properties
- Theory: Solid State Relay
- Power Source: AC (for SSR-41FDA load side) / DC (for SSR-41FDD load side)
- Contact Load: Low Power
- Use: Protective
- Protect Feature: Sealed
- Certification: CE
4. Installation and Setup
Before installation, ensure all power sources are disconnected to prevent electrical shock. These relays are designed for insert installation into compatible sockets or PCBs.
4.1. Wiring Instructions for SSR-41FDA (DC Control AC)
This model switches an AC load using a DC control signal.

- Connect the DC control voltage (3-32VDC) to terminals -4 and +3 of the SSR. Ensure correct polarity.
- Connect the AC power source to one side of the AC load.
- Connect the other side of the AC load to terminal 1~ of the SSR.
- Connect the remaining terminal 2~ of the SSR to the other side of the AC power source.
- Ensure all connections are secure and insulated.
4.2. Wiring Instructions for SSR-41FDD (DC Control DC)
This model switches a DC load using a DC control signal. Two common wiring configurations are shown.

- Connect the DC control voltage (3-32VDC) to terminals -4 and +3 of the SSR. Ensure correct polarity.
- Configuration 1 (Load on positive side): Connect the positive (+) of the DC power source to the positive (+) of the DC load. Connect the negative (-) of the DC load to terminal 2+ of the SSR. Connect terminal 1- of the SSR to the negative (-) of the DC power source.
- Configuration 2 (Load on negative side): Connect the positive (+) of the DC power source to terminal 2+ of the SSR. Connect terminal 1- of the SSR to the positive (+) of the DC load. Connect the negative (-) of the DC load to the negative (-) of the DC power source.
- Ensure all connections are secure and insulated.
5. Operating Instructions
Once properly installed and wired, the LCTC Slim Solid State Relay operates by applying the specified control voltage (3-32VDC) to its control terminals (-4 and +3). When the control voltage is applied, the relay will switch its load circuit ON. When the control voltage is removed, the relay will switch its load circuit OFF. The switching action is non-contact, providing fast response and long operational life.
- Activation: Apply 3-32VDC to the control terminals (-4 and +3) with correct polarity.
- Deactivation: Remove the control voltage from the control terminals.
- Load Compatibility: Ensure the load voltage and current are within the specified ranges for your specific SSR model (SSR-41FDA for AC loads, SSR-41FDD for DC loads).
6. Maintenance
LCTC Solid State Relays are designed for long-term, maintenance-free operation. However, periodic checks can help ensure optimal performance:
- Visual Inspection: Periodically inspect the relay and its connections for any signs of damage, overheating, or loose wiring.
- Cleanliness: Keep the relay free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning if necessary.
- Environmental Conditions: Ensure the operating environment remains within the recommended temperature and humidity ranges to prevent premature failure.
7. Troubleshooting
If the relay is not functioning as expected, consider the following troubleshooting steps:
- No Load Switching:
- Verify that the control voltage (3-32VDC) is correctly applied to terminals -4 and +3 with the correct polarity.
- Check if the load circuit has power and if the load itself is functional.
- Ensure the load voltage and current are within the relay's specifications.
- Confirm that the correct relay model is being used for the load type (SSR-41FDA for AC, SSR-41FDD for DC).
- Relay Always ON/OFF:
- Inspect wiring for short circuits or open circuits in the control or load side.
- Ensure the control signal is switching correctly (i.e., it goes to 0V when OFF and 3-32VDC when ON).
- Overheating:
- Ensure the load current does not exceed the 6A peak current rating.
- Consider using a heatsink if the relay is operating at higher currents or in high ambient temperatures, although not explicitly required for this slim model, it's good practice for higher loads.
8. User Tips
- Always match the relay type to your load: SSR-41FDA for AC loads and SSR-41FDD for DC loads. Using the wrong type can damage the relay or the load.
- For inductive DC loads, consider adding a freewheeling diode across the load to protect the relay from voltage spikes.
- While these are low-power relays, ensure adequate ventilation, especially if multiple relays are used in an enclosed space.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.