1. Introduction
The EARU EAEMP3C-100-TY-W is a smart 3-phase energy meter and protector designed for comprehensive electrical system management. It offers real-time monitoring of energy consumption, voltage, current, and frequency, along with advanced protection features against over/under voltage, over/under current, leakage, and high temperature. Integrated with Tuya WiFi, it allows for remote control and monitoring via a smartphone application, supporting voice control through Google Assistant and Amazon Alexa.
2. Safety Information
WARNING: Installation must be performed by a qualified electrician. Disconnect power before installation or maintenance. Do not operate the device if it is damaged. Ensure proper grounding. Follow all local electrical codes and regulations.
- Always wear appropriate personal protective equipment (PPE) during installation.
- Do not expose the device to moisture or extreme temperatures.
- Ensure all connections are secure and correctly wired to prevent electrical hazards.
3. Package Contents
Verify that all items are present in the package:
- 1 x EARU EAEMP3C-100-TY-W Smart Energy Meter & Protector Unit
- 1 x Current Transformer (CT)
- 1 x User Manual (this document)
4. Specifications
| Attribute | Value |
|---|---|
| Model Number | EAEMP3C-100-TY-W |
| Rated Voltage | AC380V |
| Operation Voltage | AC80V-400V (Single Phase) |
| Rated Frequency | 50Hz/60HZ |
| Max Operating Current | 80A - 99A |
| Measuring Energy Range | 0-9999999.99kWh |
| Accuracy Class | 1% |
| Phase | Three Phase |
| Power Supply | AC |
| Display Type | LCD |
| Operating Temperature | -30℃~70℃ |
| Dimensions | 90*77*75.5mm |
| Certification | CE, FCC, RoHS, KC |
| Over Voltage Limit | 120-300V (Adjustable) (Default:275V) |
| Under Voltage Limit | 80-210V (Adjustable) (Default:175V) |
| Over Current Limit | 1-100A (Adjustable) (Default:80A) |
| Under Current Limit | 1-100A (Adjustable) (Default:10A) |
| Leakage Current Limit | 10-99A (Adjustable) (Default:29mA) |
| High Temperature Alarm | 10℃-85℃ (Adjustable) (Default:85℃) |
| Display Mode | Display Mode 1 and 2 (Default:Display Mode 1) |
| Over & Under Voltage Protection Recovery Time | 1-9999s (Adjustable) (Default:20s) |
| Over & Under Current Protection Delay | 0000-9999s (Adjustable) (Default:5s) |
| Over & Under Current Protection Recovery Time | 0000-9999s (Adjustable) (Default:20s) |
| Under & Over Voltage Protection Delay | 1-9999s (Adjustable) (Default:3s) |
| Three-Phase Current Imbalance Alarm | 10-100% (Adjustable) (Default:20%) |
| Voltage Three-Phase Imbalance Alarm | 0-100% (Adjustable) (Default:20%) |
| Lost Current Recovery Delay Time | 1-9999s (Adjustable) (Default:20s) |
| Time Threshold of Lost Flow Event | 1-999s (Adjustable) (Default:10s) |
5. Setup
5.1 Physical Dimensions
Refer to the diagram below for the physical dimensions of the device and current transformer.

Figure 5.1: Device and Current Transformer Dimensions
5.2 Wiring Diagram
Follow the wiring diagram carefully for correct installation. Ensure all power is disconnected before proceeding.

Figure 5.2: Wiring Diagram
Note: One zero wire and three fire wires must pass through the current transformer at the same time. Otherwise, no leakage value can be detected.
Press down on the yellow button to insert the connector, then connect the connector to the transformer.
5.3 App Pairing (Tuya Smart / Smart Life)
To enable smart features, pair your device with the Tuya Smart or Smart Life application.
- Download the Tuya Smart or Smart Life app from your smartphone's app store.
- Register or log in to your account.
- On the device, the WiFi indicator light will flash. Fast flashing indicates it's searching for a WiFi signal.
- In the app, tap 'Add Device' or the '+' icon. The app may automatically detect the device.
- If the device does not connect automatically, long-press the third key on the meter's screen (the one showing voltage) for three seconds to initiate pairing mode.
- Follow the on-screen instructions in the app to complete the pairing process, including entering your WiFi network credentials.
- Once successfully paired, the WiFi indicator light will be solid, and the device will appear in your app.
Video 5.1: Demonstration of App Pairing and Basic Operation
The app interface allows for monitoring and control. An example of the app's energy statistics and settings is shown below.

Figure 5.3: Tuya Smart App Interface
6. Operating Instructions
6.1 Display Modes
The device features an upgraded color screen with two main display modes:

Figure 6.1: Device Display Modes
- Mode 1: Displays Voltage, Total Electricity Consumption, Current, Forward Electricity Consumption, Power, Reverse Electricity Consumption, Power Factor, and Frequency.
- Mode 2: Displays A-Phase Power Parameters & Temperature, B-Phase Power Parameters & Temperature, and C-Phase Power Parameters & Temperature.
6.2 Timer Functions
The device supports three time setting modes via the app:

Figure 6.2: Timer Setting Modes
- Timing Mode: Set a specific time for the device to turn on or off (e.g., turn on living room lights at 18:00).
- Countdown Mode: Set a countdown timer for the device to turn off after a specified duration (e.g., turn off bedroom lights after 20 minutes).
- Cycle Timing Mode: Schedule recurring on/off cycles (e.g., turn on before getting up, turn off after work).
6.3 Remote Control and Voice Control
Once paired with the Tuya Smart app, you can remotely control the device from anywhere. The device is also compatible with Google Assistant and Amazon Alexa for voice control commands.
7. Alarm Settings
The device offers various protection functions with adjustable alarm thresholds. The alarm function is automatically turned on after setting the threshold, and the protection tripping switch can be turned on or off.

Figure 7.1: Alarm Settings in App
7.1 Adjusting Settings on the Device
You can adjust fault settings directly on the device:

Figure 7.2: Fault Settings Adjustment Flow
- Long press OK key: To enter the settings states and show the settings.
- Change settings: Use the UP/DOWN keys to adjust values.
- Short press OK key: To confirm the settings on the current page and jump to the next settings page.
- Long press OK key: To exit the settings states and save the settings.
7.2 Key Protection Functions and Default Settings
- Over Voltage Limit: Default 275V (Adjustable 120-300V)
- Under Voltage Limit: Default 175V (Adjustable 80-210V)
- Over Current Limit: Default 80A (Adjustable 1-100A)
- Under Current Limit: Default 10A (Adjustable 1-100A)
- Leakage Current Limit: Default 29mA (Adjustable 10-99A)
- High Temperature Alarm: Default 85℃ (Adjustable 10℃-85℃)
- Over & Under Voltage Protection Recovery Time: Default 20s (Adjustable 1-9999s)
- Over & Under Current Protection Delay: Default 5s (Adjustable 0000-9999s)
- Over & Under Current Protection Recovery Time: Default 20s (Adjustable 0000-9999s)
- Under & Over Voltage Protection Delay: Default 3s (Adjustable 1-9999s)
- Three-Phase Current Imbalance Alarm: Default 20% (Adjustable 10-100%)
- Voltage Three-Phase Imbalance Alarm: Default 20% (Adjustable 0-100%)
- Lost Current Recovery Delay Time: Default 20s (Adjustable 1-9999s)
- Time Threshold of Lost Flow Event: Default 10s (Adjustable 1-999s)
8. Maintenance
- Cleaning: Keep the device clean and free from dust. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.
- Connection Check: Periodically check all wiring connections to ensure they are tight and secure. Loose connections can lead to overheating or malfunction.
- Environmental Conditions: Ensure the device is operated within its specified temperature and humidity ranges.
- Professional Service: Do not attempt to repair the device yourself. For any issues requiring repair, contact qualified service personnel.
9. Troubleshooting
- Device not powering on:
- Check the main power supply and ensure all wiring connections are correct and secure.
- WiFi connection issues:
- If the WiFi indicator light is fast flashing, it's searching for a signal. Slow flashing indicates an offline status. Long-press the third key on the meter's screen (the one showing voltage) for three seconds to initiate pairing mode if it doesn't connect automatically. Ensure your router is working and the device is within range.
- No leakage value detected:
- Ensure one zero wire and three fire wires pass through the current transformer at the same time. Incorrect CT wiring will prevent leakage detection.
- Protection tripping unexpectedly:
- Review your alarm settings (Over Voltage, Under Voltage, Over Current, etc.) in the app or on the device. Ensure the thresholds are appropriate for your electrical load and system. Check for actual electrical faults in your system.
- Inaccurate readings:
- Verify that the current transformer is correctly installed and all wiring is secure. Ensure the device is configured for the correct phase system (3-phase).
- Device unresponsive:
- Try restarting the device by cycling its power. If issues persist, consider resetting to factory settings (refer to the settings menu, default OFF).
10. User Tips
- For optimal performance, ensure your WiFi network is stable and within range of the device.
- Regularly review energy consumption statistics in the app to identify potential energy savings and optimize usage.
- Utilize the scheduling features (Timing, Countdown, Cycle Time) to automate power control for appliances and lighting, enhancing convenience and energy efficiency.
- Familiarize yourself with the alarm settings to customize protection levels according to your specific needs and local electrical standards.
11. Warranty and Support
For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Please retain your purchase receipt as proof of purchase for any warranty claims.