TKXEC SK120

Contents

SK120 Adjustable DC Voltage Buck-Boost Converter User Manual

Model: SK120 | Brand: TKXEC

1. Introduction

The SK120 is a true third-generation upgraded DC buck-boost power supply featuring an all-viewing-angle VA color LCD. It supports Constant Current (CC), Constant Voltage (CV), and Constant Power (CW) modes. This versatile module is designed for various applications, including solar charging, and offers advanced features such as firmware upgrades and Modbus protocol support.

Front view of the SK120 module with LCD display

Front view of the SK120 module, highlighting its VA color LCD and key features.

The 120W rating is conservative; with software support, the power output can reach up to 150W under optimal cooling conditions.

2. Specifications

Feature Specification
Model Number SK120
Brand Name TKXEC
Current Type DC
Input Voltage 6.0-36.00V
Output Voltage 0-36.00V
Output Current 0-6.000A
Power Output 120W (up to 150W with optimal cooling)
LCD Screen Size Visual range: 38mm x 29mm (>1.8 inches)
Dimensions (L x W x H) 79mm x 50mm x 43mm
Product Weight 108g
Protection Features Anti-reverse, Anti-backflow, Under-voltage, Over-voltage, Over-current, Over-temperature, Over-power
Storage Groups 10 (Cd0-Cd9)
Communication Standard Modbus protocol, supports WiFi module for APP/web control, XY-K485X module for 485 bus control
Product dimensions and package size

Physical dimensions of the SK120 module and its packaging.

3. Product Overview

3.1 Functional Interfaces and Wiring

Internal wiring diagram and functional interfaces of the SK120

Diagram showing the internal components and external interfaces for wiring.

  • Input Terminals: IN+ and IN- for DC input voltage (DC6.0-70V).
  • Output Terminals: OUT+ and OUT- for DC output.
  • Power Battery Interface: For connecting external battery sources.
  • PD Interface: Automatically activates 20V high voltage output when a PD charging head is inserted.
  • DC5.5*2.5 Plug: Standard DC input jack.
  • Plug-in Terminal: Additional input/output connection point.
  • Exhaust Fan: Intelligent temperature-controlled fan for heat dissipation.
  • Spare Expansion Port: Can be used for additional functionalities.
  • 10k NTC 3905B External Temperature Sensor Interface: For connecting an external temperature probe.
  • Serial Communication Interface: For Modbus protocol and connecting optional modules.

3.2 Display and Controls

Product UI function details showing various display modes

Detailed view of the LCD display in various operational modes (ON, OFF, CC, CW).

The VA color LCD provides a clear display of operational parameters. Key elements include:

  • VSET Button: Used for setting voltage.
  • SW Button: Used for switching displays and entering settings.
  • ISET Button: Used for setting current.
  • Encoder Knob: For adjusting values and navigating menus.
  • ON/OFF Indicator: Shows the power supply status.
  • Output Parameters: Displays Output Voltage (CV), Output Current (CC), Power (W), Capacity (Ah), Energy (Wh), Time (h), and Temperature (°C).

4. Setup

4.1 Basic Wiring

Connect your power source to the IN+ and IN- terminals and your load to the OUT+ and OUT- terminals. Ensure correct polarity to prevent damage.

  • Input: Connect your DC power source (6.0-36.00V) to IN+ (positive) and IN- (negative).
  • Output: Connect your load to OUT+ (positive) and OUT- (negative).

Attention: This product does not have output reverse connection protection. Reversing the positive and negative terminals of the battery will damage the device. Battery charging requires certain professional knowledge. Non-professionals are not allowed to charge directly to prevent fire and explosion.

4.2 Optional Module Connections

  • XY-K485X Module: Connect to the serial communication interface for 485 bus control.
  • WiFi Module: Connect to the serial communication interface to enable remote control via APP and web-based networking control.
  • External Temperature Probe: Connect a 10k NTC 3905B external temperature sensor to the dedicated interface. When connected, the display will automatically show the probe's temperature.
Diagram showing MPPT solar charging and external temperature probe connection

Example connection for MPPT solar charging with an external temperature probe.

5. Operating Instructions

Instructions for Use: Setting Voltage and Current, Quick Setting, Display, Key Lock

Visual guide for basic operation and settings.

5.1 Setting Voltage and Current

  1. On the main UI, briefly press the VSET button to set the voltage. The LCD will display "SET" in the lower row, and "CV" will flash to indicate that the voltage setting position is selected and blinking.
  2. Briefly press the SW button or rotate the encoder button to switch the voltage setting position.
  3. Adjust the value by rotating the encoder.
  4. After setting is complete, briefly press the VSET button to exit and save.
  5. To set the current, briefly press the ISET button, and the setting steps are the same as for voltage.

5.2 Quick Setting of Voltage or Current (FET)

In the system parameter settings UI, set the parameter FET to CV (Constant Voltage) or CC (Constant Current). Rotate the encoder on the main UI to enter the voltage or current setting UI. Rotate the encoder to quickly set the voltage or current.

5.3 Input/Output Voltage Display

On the main UI, briefly press the SW button to switch between input and output voltage displays.

5.4 Checking Power (W), Capacity (Ah), Energy (Wh), Time (h), Temperature (°C)

On the main UI, press the encoder button briefly to switch between displaying power (W), capacity (Ah), energy (Wh), time (h), and temperature (°C) in rotation.

5.5 Key Lock

On the main UI, press and hold the encoder button for 2 seconds to lock the set voltage and current to prevent misoperation. Press and hold the encoder button for 2 seconds after locking to unlock.

5.6 CV/CC/CW Functions

Explanation of Constant Voltage, Constant Current, and Constant Power functions

Detailed explanation of CV, CC, and CW operating modes.

  1. Constant Current (CC) and Constant Voltage (CV) Modes:
    • When the load current is less than the set constant current value, the power supply operates in constant voltage mode, with the output voltage set to CV and adaptive current.
    • When the load current exceeds the set constant current value, the power supply automatically enters constant current mode, with the output current set to CC and adaptive voltage.
  2. Constant Power (CW) Mode:
    • After the constant power function is turned on, the constant voltage defaults to the maximum value, and the constant voltage value CV serves as the initial voltage (set to a reasonable value based on actual conditions).
    • The power supply calculates the equivalent resistance R of the load using Ohm's law (R=U/I). The corresponding voltage can be calculated based on the set constant power value using the formula P=U²/R.
    • The constant power point algorithm automatically follows, and the constant power is achieved.

Constant Power Switch and Constant Power Value Setting:

  1. Press and hold SW on the main UI to enter the system settings menu.
  2. Press ISET/VSET briefly to switch to the "-CP-" constant power switch option. Press ON to enable constant power and OFF to disable it.
  3. After enabling constant power, press ISET briefly on the main interface to modify the value of constant power.

6. System Parameter Settings

Press and hold the SW button on the main interface to enter the settings menu. Briefly press VSET to select the next parameter, and briefly press ISET to select the previous parameter. After completing the settings, press and hold the SW/encoder button to exit the settings.

System Parameter Settings UI showing various configurable options

Overview of the system parameter settings interface.

Parameter Description Default
bEPTurn on/off the buzzerOn
b-LLCD brightness adjustmentBrightest
C-FCelsius (°C) and Fahrenheit (°F) selection°C
FEFQuick voltage or current adjustmentCV
AddSet the device address001
bRESet the device communication baud rate115200
PPtMPPT solar charging settingsOff
-CP-Constant Power CW ON/OFFOff
btPSet the charging cut-off currentOff
CLUCalibrate the output voltage--
CLACalibrate the output current--
ZEROCurrent zero calibration0.000
CLOFForce the power output to turn off when retrieving data groupsOff
rEFRestore factory settings--
VErFirmware version number1.0.1

7. Data Group Function

This product has a total of 10 data groups, from Cd0 to Cd9. Press and hold the VSET button on the main UI to access the data group UI.

Data Group Function UI showing various protection settings

Data Group UI with settings for voltage, current, and various protection parameters.

You can briefly press VSET/ISET to switch between constant voltage (CV) and constant current (CC) settings within a data group. It supports quick viewing and modification of voltage and current, as well as SW shift operation.

After confirming the data group, press and hold the VSET/SW button or press the encoder button briefly to select the desired data group.

7.1 Protection Parameters within Data Groups

  • UVP (Input Undervoltage Protection): Default 5.5V
  • OVP (Output Overvoltage Protection): Default 38V
  • OCP (Output Overcurrent Protection): Default 6.2A
  • OPP (Output Overpower Protection): Default 125W
  • OAH (Overcapacity Protection): Default off
  • OPH (Overenergy Protection): Default off
  • OHP (Overtime Protection): Default off
  • OTP (Overtemperature Protection): Default 95°C
  • ETP (External Overtemperature Protection): Default off
  • POn (Automatically Enabled During Power-on): Default off

8. Firmware Upgrade

The product supports firmware upgrades to obtain new functions. At present, it only supports firmware upgrades through the WiFi module. In the future, it will also be able to upgrade through multi-serial port host computer software (under development).

Firmware upgrade screen showing version, steps, and progress

Example of the firmware upgrade display.

Note: Do not power off during the product upgrade process. If the product upgrade fails, you can press and hold the power button to power on the product and force it into the upgrade mode.

9. Troubleshooting

  • No current output flow, even if display shows current >0: This could indicate a blown or damaged IC, or incorrect wiring.
  • General Power Issues: Ensure all connections are secure and correctly polarized. Verify the input voltage is within the specified range (6.0-36.00V).
  • Display Malfunctions: Check power connections. If the display is unresponsive, try a factory reset (rEF in system settings).
  • Over-protection Triggered: If the device shuts down unexpectedly, check the set protection parameters (UVP, OVP, OCP, OPP, OTP, etc.) in the data groups. Adjust them if they are too restrictive for your application.

10. User Tips

  • Wiring Caution: Always double-check wiring, especially polarity, before powering on the device to prevent damage to the module or connected components.
  • Cooling: For sustained high power output (above 120W, up to 150W), ensure adequate cooling and airflow around the module.
  • Software Updates: Regularly check for firmware updates via the Sinilink APP or official website to benefit from new features and improvements.
  • Professional Knowledge for Battery Charging: When using the module for battery charging, ensure you have the necessary professional knowledge to avoid hazards like fire or explosion, especially regarding output reverse connection.

10.1 Software Download

For remote control and firmware updates, download the official software:

11. Warranty and Support

For warranty claims, technical support, or further assistance, please contact your seller or the manufacturer directly. Keep your purchase records for reference.

© 2023 TKXEC. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.