TKXEC SK120

Contents

TKXEC SK120 120W DC DC Buck Boost Converter User Manual

Model: SK120 | Brand: TKXEC

1. Introduction and Overview

The TKXEC SK120 is a true third-generation upgraded DC buck-boost power supply module featuring an all-viewing-angle VA color LCD. It supports Constant Voltage (CV), Constant Current (CC), and Constant Power (CW) modes, making it versatile for various applications including solar charging. This module offers a wide input voltage range of 6.0-36V and an adjustable output from 0-36V, with a maximum output current of 6.000A and a conservative power rating of 120W, capable of reaching up to 150W under optimal cooling conditions. It includes advanced features such as anti-backflow, MPPT solar charging support, and standard Modbus protocol for serial communication. The device also incorporates an intelligent temperature-controlled fan and comprehensive protection mechanisms.

SK120 DC Buck Boost Converter with VA color LCD display
Figure 1: SK120 DC Buck Boost Converter with VA color LCD display, highlighting key features and specifications.

2. Specifications

ParameterValue
Model NumberSK120
Brand NameTKXEC
Input VoltageDC 6.0V - 36.0V (DC6.0-70V via plug-in terminal)
Output Voltage0V - 36.0V
Output Current0A - 6.000A
Power Output120W (Conservative, up to 150W with optimal cooling)
DisplayVA Color LCD (>1.8 inches, 38x29mm visual range)
Data Storage10 data groups (Cd0-Cd9)
CommunicationModbus protocol, optional WiFi module, optional XY-K485X module
CoolingIntelligent Temperature-Controlled Fan, large-area ventilation heat sinks
Protection FeaturesAnti-reverse, Anti-backflow, Under-voltage (LVP), Over-voltage (OVP), Over-current (OCP), Over-power (OPP), Over-temperature (OTP), External Over-temperature (ETP), Over-capacity (OAH), Over-energy (OPH), Over-time (OHP)
Dimensions (Module)79mm (L) x 50mm (W) x 43mm (H)
Weight (Module)108g
Dimensions (Finished Product)111mm (L) x 65mm (W) x 57mm (H)
Weight (Finished Product)296g

3. Setup

3.1 Wiring and Connections

Carefully connect the input and output terminals. Ensure correct polarity to prevent damage. The module features IN+ and IN- for input, and OUT+ and OUT- for output. The device also includes various interfaces for expanded functionality.

Functional Interfaces and Wiring Diagram for SK120
Figure 2: Diagram illustrating the functional interfaces and wiring connections, including input/output terminals, serial communication, and optional module connections.
  • Input Terminals: Connect your DC power source to IN+ (positive) and IN- (negative). The module supports DC 6.0-36V via standard terminals and DC 6.0-70V via the plug-in terminal.
  • Output Terminals: Connect your load to OUT+ (positive) and OUT- (negative).
  • PD Interface: For Power Delivery charging heads, inserting a PD charging head will automatically activate a 20V high voltage output.
  • Power Battery Interface: Dedicated interface for battery connections.
  • External Temperature Sensor: Connect a 10k NTC 3905B external temperature sensor to the designated interface for over-temperature protection and MPPT solar charging.
  • Optional Modules:
    • XY-K485X Module: Can be connected for 485 bus control.
    • WiFi Module: Enables remote control via APP and web-based networking.
Rich input interface options for SK120
Figure 3: Overview of the various input interfaces available on the SK120 module, including PD, power battery, DC plug, and plug-in terminals. Note: Do not simultaneously access two or more input interfaces.

3.2 Initial Power-up

After ensuring all connections are secure and correct, apply power to the input terminals. The VA color LCD will illuminate, displaying the current operating parameters. The intelligent temperature-controlled fan will activate as needed to manage heat dissipation.

4. Operating Instructions

4.1 User Interface (UI) Navigation

The SK120 features a clear VA color LCD with large fonts for easy readability. The main UI displays input voltage, output voltage, output current, and power output.

  • Input/Output Voltage Display: On the main UI, briefly press the SW button to switch between displaying input voltage and output voltage.
  • Parameter Cycling: Briefly press the encoder button on the main UI to cycle through displaying power (W), capacity (Ah), energy (Wh), time (h), and temperature (°C).
Product UI function details and display modes
Figure 4: Detailed view of the product UI, showing constant voltage (CV), constant current (CC), and constant power (CW) display modes, along with other parameters.

4.2 Setting Voltage and Current

To set the desired output voltage and current:

  1. Set Voltage: Briefly press the VSET button. The LCD will display "SET" and "CV" will flash. Use the SW button or the encoder to select the digit to adjust. Rotate the encoder to change the value. Briefly press VSET again to exit and save.
  2. Set Current: Briefly press the ISET button. The LCD will display "SET" and "CC" will flash. The setting procedure is identical to setting the voltage.
Instructions for setting voltage and current on the SK120
Figure 5: Visual guide for setting output voltage and current using the VSET, SW, and ISET buttons, and the encoder.

4.3 Key Lock Function

To prevent accidental changes to settings:

  • Lock: On the main UI, press and hold the encoder button for 2 seconds. A lock symbol will appear on the display.
  • Unlock: Press and hold the encoder button for 2 seconds again. The lock symbol will disappear.
Key lock function on the SK120 display
Figure 6: Illustration of the key lock feature, showing how to activate and deactivate it to prevent unintended parameter changes.

4.4 Data Group Function

The SK120 supports 10 data groups (Cd0 to Cd9) for saving and recalling frequently used voltage and current settings.

  • Access Data Group UI: Press and hold the VSET button on the main UI.
  • Switch Settings: Briefly press VSET/ISET to switch between CV and CC settings within the data group.
  • Select Data Group: After confirming the data group, press and hold the VSET/SW button or briefly press the encoder button to select the desired data group.
Data Group Function UI for SK120
Figure 7: Explanation of the Data Group Function, showing how to access and manage the 10 programmable data groups.

4.5 System Parameter Settings

To access advanced system settings:

  1. Enter Settings Menu: Press and hold the SW button on the main interface.
  2. Navigate Parameters: Briefly press VSET to select the next parameter, and ISET to select the previous parameter.
  3. Adjust Values: Use the encoder to change parameter values.
  4. Exit Settings: After completing adjustments, press and hold the SW or encoder button.

Key parameters include:

  • bEP: Buzzer setting (ON/OFF).
  • b-L: LCD brightness adjustment.
  • C-F: Celsius and Fahrenheit temperature unit selection.
  • FEt: Quick voltage or current adjustment (CV/CC).
  • Add: Device address for communication.
  • bRE: Baud rate for serial communication.
  • PPt: MPPT solar charging settings.
  • .CP: Constant Power ON/OFF.
  • bTP: Charging cut-off current.
  • CLU/CLA: Output voltage/current calibration.
  • ZERO: Current zero calibration.
  • CLOF: Force power output to turn off when retrieving data groups.
  • rEF: Restore factory settings.
  • VEr: Firmware version number.
System Parameter Settings UI for SK120
Figure 8: Comprehensive display of all system parameter settings accessible through the UI.

4.6 CV/CC/CW Functions

The SK120 operates in Constant Voltage (CV), Constant Current (CC), or Constant Power (CW) modes depending on settings and load conditions.

  • Constant Power Function OFF: The module automatically switches between CV and CC based on the load.
    • If load current is less than the set current, it operates in CV mode (output voltage = set CV, current is adaptive).
    • If load current exceeds the set current, it operates in CC mode (output current = set CC, voltage is adaptive).
  • Constant Power Function ON: The constant current value defaults to maximum, and the constant voltage (CV) is set as the initial voltage. The module calculates load resistance (R=U/I) and adjusts voltage based on the set constant power (P=U²/R) to maintain constant power output.

Setting Constant Power:

  1. Press and hold SW on the main UI to enter system settings.
  2. Briefly press ISET/VSET to navigate to the ".CP" constant power switch option. Press ON to enable or OFF to disable.
  3. After enabling, briefly press ISET on the main interface to modify the constant power value.
Introduction to CV, CC, and CW Functions
Figure 9: Detailed explanation of Constant Voltage (CV), Constant Current (CC), and Constant Power (CW) operating modes.

4.7 MPPT Solar Charging

The SK120 supports MPPT (Maximum Power Point Tracking) solar charging with an anti-backflow function, allowing it to charge various rechargeable batteries.

  • Connect a solar panel to the input and a battery to the output.
  • Attach a 10k NTC 3905B external temperature probe to the battery for over-temperature protection. The module will automatically stop charging if the battery overheats.
  • When the temperature probe is connected, a battery icon will be displayed on the LCD.

WARNING: This product does NOT have output reverse connection protection. Reversing the positive and negative terminals of the battery will damage the device. Battery charging requires professional knowledge. Non-professionals should not attempt direct charging to prevent fire and explosion.

MPPT Solar Charging with anti-backflow function
Figure 10: Diagram showing the setup for MPPT solar charging, including solar panel, battery, and external temperature probe connection.

5. Maintenance

To ensure the longevity and optimal performance of your SK120 module:

  • Cleaning: Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
  • Ventilation: Ensure the air inlets and exhaust fan are not obstructed. The module has an intelligent temperature-controlled fan and large heat sinks for efficient heat dissipation. Proper airflow is crucial for maintaining performance, especially at higher power outputs.
  • Storage: Store the module in a dry, cool environment away from direct sunlight and extreme temperatures.
  • Connections: Periodically check all wiring connections to ensure they are secure and free from corrosion.
Internal components and cooling system of SK120
Figure 11: Internal view highlighting the intelligent temperature-controlled fan and large-area ventilation heat sinks, crucial for maintaining optimal operating temperature.

6. Troubleshooting

If you encounter issues with your SK120 module, consider the following:

  • No Power/Display: Check input power connections and ensure the input voltage is within the specified range (6.0-36V).
  • Incorrect Output: Verify your voltage and current settings. Ensure the key lock is not active if you are unable to change settings. Check for proper load connection.
  • Over-Protection Triggered: The module has multiple protection features (LVP, OVP, OCP, OPP, OTP, ETP, OAH, OPH, OHP). If output is cut off, check for conditions that might trigger these protections (e.g., input undervoltage, output overvoltage/overcurrent/overpower, high temperature, over-capacity, over-energy, or excessive operating time). Address the underlying cause before resuming operation.
  • Firmware Upgrade Failure: If a firmware upgrade fails, do not power off the device. Press and hold the power button to force the product into upgrade mode and retry the upgrade.
  • Communication Issues: If using optional WiFi or K485X modules, ensure they are correctly installed and configured according to their respective instructions. Check baud rate settings in the system parameters.

7. User Tips

Here are some general tips for using your SK120 module effectively and safely:

  • Always double-check wiring polarity, especially when connecting batteries for charging, to avoid damage to the device and potential hazards.
  • When operating at higher power outputs (closer to 120W or 150W), ensure adequate ventilation around the module to allow the intelligent fan and heat sinks to function optimally.
  • Utilize the 10 data groups to save frequently used voltage and current settings for quick recall, improving efficiency in repetitive tasks.
  • Familiarize yourself with the system parameter settings, particularly the protection limits (LVP, OVP, OCP, OPP, OTP), to configure the module safely for your specific application.
  • For solar charging applications, the external NTC temperature probe is highly recommended for battery protection.

8. Warranty and Support

The TKXEC SK120 module is designed for reliable performance. For technical support or inquiries, please refer to the seller's contact information or the official product page.

8.1 Firmware and Software

The product supports firmware upgrades to obtain new functions, primarily through the optional WiFi module. Future upgrades via multi-serial port host computer software are under development.

APP Download Address:

Computer Client Software Download Address:

Firmware upgrade process for SK120
Figure 12: Illustration of the firmware upgrade interface, showing version number, steps, and progress indicators.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.